QuVa Pharma , Inc. Form 483, October 2022
FDA issued this Form 483 to QuVa Pharma , Inc. in Bloomsbury, New Jersey (FEI 3013931875) at the end of a drug inspection that ended October 14, 2022. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on January 26, 2024.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Dec 7, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Oct 14, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Dec 7, 2022
- 54 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Failure to review unexplained discrepancies and mold
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A) No documented review was performed when mold was recovered on an operator (b) (4) plate sample taken on 06/29/2022 after ISO 5 operations in Clean Room (b) (4) and the clean room experienced elevated temperature and relative humidity excursions beyond the set alarm points. This mold recovery on 06/29 was the third mold recovery on (b) (4) plates in three (3) months. In addition, a documented risk assessment was not performed on products produced after the mold recoveries in the same cleanrooms or ISO 5 hoods. Mold was recovered on operators (b) (4) after ISO 5 operations (listed below) and the product was released and/or the bulk material was used to produce Compounded Sterile Product (CSP) which were released between 05/26/2022 - 07/26/2022. Product (Bulk /CSP): Fentanyl Citrate, PF, 10 mcg/mL in NS 3 L Bulk Bag (Bulk), Bulk Lot# (b) (4) (05/12/2022), Date Compounded 04/15/2022, Mold Identification on one (1) Hand (Colony Forming Units (CFU#)) Rhizopus oryzae (1), CSP Lot# (Expiration Date) N/A. Product (Bulk /CSP): Ketamine HCl 20 mg (10 mg/ml), 2ml in 0.9% Sodium Chloride solution in a 3ml Syringe (CSP), Date Compounded 05/12/2022, Mold Identification Aspergillus tonophilus (1), CSP Lot# (b) (4) (08/10/22). Product (Bulk /CSP): Amiodarone HCl 1.8mg/mL in Dextrose 5% in (b) (4), 3L, Bulk Bag (Bulk), Bulk Lot# (b) (4) (07/20/2022), Date Compounded 06/29/2022, Mold Identification Arthrinium arundinis/sacchari (1), Lot# (b) (4) (08/27/22). B) Your firm's Deviation Investigation, DEV-01639, Dated: 02/22/2022, initiated due to microbial recovery on personnel monitoring plates (2 CFUs on (b) (4); Action level (b) (4) on one (b) (4) or (b) (4) on each (b) (4);) after compounding Oxytocin 20 units added to (b) (4) 0.9% Sodium Chloride IV bag, Compound Date: 02/14/2022, Lot # (b) (4), Expiration Date: 05/15/2022, in ISO 5 LAF (Equipment ID: NJ-LAF(b) (4)) in Cleanroom (b) (4) is inadequate. One of the two microbial recoveries were identified as Peribacillus simplex/Brevibacterium (Peribacillus) frigoritolerans, a spore forming bacteria, and the second microbial recovery was unable to be identified due to DNA degradation. Your firm did not evaluate the room environmental conditions, such as temperature and humidity, as part of the investigation. Additionally, no second person verification of (b) (4) colony counts is conducted and no other information, such as the morphology and/or Gram stain, about the second isolated CFU is available; your firm deemed the lot of Oxytocin eligible for release and distributed this product over the period of 03/25/2022 - 03/29/2022. C) The environmental monitoring data for temperature and relative humidity (RH), that is captured by the (b) (4) (b) (4) for ISO 7 Cleanrooms in Building (b) (4), are not reviewed and recordings exceeding alarm points are not investigated. Temperature readings exceeding the "High" and RH readings exceeding the "High High" alarm points were observed in cleanrooms in Building (b) (4) on 06/27/2022, 06/29/2022 and 07/21/2022 (listed in table below); no incident reports were initiated for these high temperature and humidity readings. Approximate (b) (4) Recording (Temperature: High Alarm Point: (b) (4), High High Alarm Point: (b) (4) (Humidity: High Alarm Point (b) (4) High High Alarm Point: (b) (4)) Date Room# (Clean Room (CR-#)) Temperature (C) Humidity (%): 06/27/2022 (b) (4) 20 78; 06/29/2022 22 78; 07/21/2022 22 78; 06/27/2022 21 78; 06/29/2022 23 78; 07/21/2022 22.8 78; 06/27/2022 21 79; 06/29/2022 (b) (4) 23.5 78; 07/21/2022 22.8 79; 06/27/2022 21.2 80; 06/29/2022 23.8 76; 07/21/2022 22.6 79; 06/27/2022 20.8 80; 06/29/2022 23.2 79; 07/21/2022 22.8 79; 06/27/2022 21.2 77; 06/29/2022 23.4 77; 07/21/2022 23 77. D) Your firm did not initiate an Incident Report (IR) when low pressure gauge readings in the ISO 5 hood and light brown stain o
Shortened here; the PDF has the full text.
- 2
Deficient environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, Your firm's environmental and personnel monitoring program does not include sampling of all potential routes of microbial contamination. For example: A) On 08/16/2022, during our observation of sterile filling of Epinephrine, Preservative Free (PF), 10mcg/ml in 10ml Dextrose 5% in (b) (4) (D5W) Syringe, Lot# (b) (4), Expiration Date: 11/14/2022 within the ISO 5 (b) (4) Laminar Air Flow (b) (4) syringe filling machine (Equipment ID: NJ-(b) (4)), located in Cleanroom (b)(4) (ISO 7), we observed the operator place their upper left side of the body (including head, chest, and sleeves) into the ISO 5 area within the syringe filler. However, only (b) (4) samples are collected at the completion of each production lot. We also witnessed the operator open the Zone (b)(4) and Zone (b)(4) doors (located behind the bulk product source bag) of the (b) (4) fill machine into the ISO 7 area; however, no surface samples are collected from the Zone (b)(4) or Zone (b)(4) doors. B) On 08/18/2022, during our observation of the sterile filling of Fentanyl PF, 10 mcg/ml in 100 ml Normal Saline (NS) IVB, Lot# (b) (4), Expiration Date: 11/16/2022, within the ISO 5 (b) (4) hood (Equipment ID: NJ-LAF-(b) (4)) located in Cleanroom (b)(4) (ISO 7), we observed the operator placing sleeves, chest, and forehead under the hood. However, only (b) (4) samples are collected at the completion of each production lot. Additionally, the (b) (4) plate is placed at the far-right or far-left corner of the (b) (4) and is not placed close to the area of operation most prone to contamination.
- 3
Inadequate visual inspection procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm's visual inspection procedure utilized during Inspection, Labeling and Packaging (ILP) of sterile products, are deficient for the following reasons: A) The (b) (4) and defect (b) (4) that is used to train and qualify visual inspection operators and AQL visual inspectors do not include representative defects for "debris" and "excessive liquid between plunger ribs". For example, your firm categorizes "particulates" and "debris" as two different defects to identify during (b) (4). The defect (b)(4) used to qualify operators for visual inspection includes seed material for particulates such as (b) (4), (b) (4), (b) (4), (b) (4) and (b) (4); there are no seed materials or examples representative of debris in the defect (b)(4) or defect (b) (4) respectively. Debris was identified in (b) (4) of Ropivacaine HCl, Epinephrine, Clonidine HCl, Ketorolac Tromethamine (R.E.C.K) 50 ml in Sodium Chloride 50ml syringe, Lot# (b) (4), Expiration Date: 11/02/2022 and in (b) (4) during inspection of Phenylephrine HCl 1 mg (100 mcg/ml) 10 ml in 0.9% Sodium Chloride solution 10ml syringe KCT, Lot# (b) (4), Expiration Date: 11/07/2022. Additionally, the Quality Assurance AQL Inspection Form "NJ-(b) (4)" used by AQL visual inspectors include the following minor defect to identify during AQL visual inspection: Excessive liquid between plunger ribs. However, (b) (4) and the defect (b) (4) does not include representative defects for "excessive liquid between plunger ribs". There is no assurance that all visual inspectors can accurately identify debris or excessive liquid between plunger ribs in syringes. B) The ILP section of the Batch Production Record (BPR) for syringe products such as (b) (4) 50 ml in Sodium Chloride 50ml syringe (Lot# (b) (4), Expiration Date: 11/02/2022), Phenylephrine HCl 1 mg (100 mcg/ml) 10 ml in 0.9% Sodium Chloride solution 10ml syringe KCT (Lot# (b) (4), Expiration Date: 11/07/2022) and Lidocaine HCl PF 1%, 100 mg/10 mL, 10ml syringe (Lot# (b) (4), Expiration Date: 09/29/2022) does not include a section for operators to identify and record defects related to leaking syringes. Regarding actively leaking units, Work Instructions NJ-WI-PO-0020 "Identification and Definition of Defects in Products During Visual Inspection" Revision 2, Effective 10 Aug 2021 states, "(b) (4)". According to management, leaking syringes are recorded in the "other" defects section; however, the batch record does not include a section for the description of "other" defects identified during (b) (4).
- 4
Lack of computer system access controls
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A) During review of user access rights for the (b) (4) (Equipment ID: (b) (4) (b) (4)), in Building (b) (4) which are used to test the (b) (4) of the (b) (4) used to sterilize in process bulk, it was observed that all operators access the software with the (b) (4) and share a common username and password. We also observed that the (b) (4) function for the results was enabled for the (b) (4). Additionally, the (b) (4) equipment ID is not recorded in the Batch Production Records. B) During review of user access rights on the (b) (4) Endotoxin Unit (Equipment ID: NJ-END-(b) (4)), which is used for finished product release endotoxin testing for all compounded sterile product, it was observed that all microbiologists who perform endotoxin testing have (b) (4) user privileges to the (b) (4) where results generated from the (b) (4) Software are stored; the (b) (4) permission permits users to delete files and folders. C) During walkthrough of the QC laboratory and review of data in the (b) (4) software, we observed that Senior Chemist (b) (6) who routinely conducts analytical testing of finished sterile products, and raw materials, had (b) (4) roles assigned and has final data review and approve privileges in (b) (4) enabled. Prior to (b) (6) role as a Senior Chemist, (b) (6) functioned as a Reviewer; however, Senior Chemist (b) (6) has not functioned in the capacity of a reviewer for approximately (b) (4).
- 5
Sterile contamination prevention procedures not followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Specifically, A) Smoke studies conducted on 09/08-09/10/2021 in the ISO 5 (b) (4) syringe filler (Equipment ID: NJ (b) (4)-(b) (4)) and on 02/24/2022 in the ISO 5 LAF Hood (Equipment ID: NJ-LAF-(b) (4)) are inadequate. Specifically, during the smoke studies, the (b) (4) system was not turned on during dynamic study to demonstrate that the (b) (4) system does not alter or impede the unidirectionality of air from the HEPA filter to the ISO 5 area of the (b) (4) syringe filler or laminar air flow hoods where products are aseptically processed. B) During observation of sterile production activities, the following deficiencies in aseptic behaviors and gowning were observed: i. On 08/16/2022, during the sterile filling of Epinephrine, Preservative Free (PF), 10mcg/ml in 10ml Dextrose 5% in (b) (4) Syringe, Lot# (b) (4), within the ISO 5 (b) (4) Air Flow (b) (4) syringe filling machine (Equipment ID: NJ-(b) (4)), located in Cleanroom (b) (4) (ISO 7), we observed the operator's sterile gown was not zipped completely and was not buttoned at the collar while performing operations in the ISO 5 area. We also observed the operator place their upper left side of the body (including head, chest and sleeves) into the ISO 5 area within the syringe filler. Additionally, the operator did not clean the Zone (b) (4) and Zone (b) (4) doors of the syringe filling machine after opening the doors to the ISO 7 room to perform interventions and prior to closing the doors. ii. On 08/18/2022, during the sterile filling of Fentanyl PF, 10 mcg/ml in 100 ml Normal Saline (NS) IVB, Lot# (b) (4), within the ISO 5 (b) (4) LAF ((b) (4)) hood (Equipment ID: NJ-LAF(b) (4)) located in Cleanroom (b)(4) (ISO 7), we observed the operator placing sleeves, chest and forehead under the hood. Additionally, we observed the operator use one (1) sterile wipe to clean the ports on all (b) (4) bags placed in the ISO 5 hood; however, Section 3.2.30 of work instructions NJ-WI-PO-0021 "Batch Preparation and Dosing of IV Bags", Revision 16, Effective 28 Feb 2022, states to (b) (4). We also observed an operator's sterile gown was not zipped completely and was not buttoned at the collar while performing operations in the cleanroom.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJan 26, 2024QuVa Pharma, Inc. warning letter, January 26, 2024CDER · 469 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3013931875, newest first.
- Form 483, April 2025Inspection ended Apr 4, 2025 · Posted May 7, 2025OAI
- Form 483, May 2019Inspection ended May 31, 2019 · Posted Jul 25, 2019OAI
- Form 483, November 2017Inspection ended Nov 30, 2017 · Posted Jan 17, 2024VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.