Carolina Infusion Form 483, August 2022
FDA issued this Form 483 to Carolina Infusion in Ridgeland, South Carolina (FEI 3015826782) at the end of a drug inspection that ended August 12, 2022. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on June 9, 2023.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 16, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 12, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 16, 2022
- 96 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Endotoxin control failures
Your firm produced drug products with materials that had not been verified to not contribute endotoxin contamination that may be objectionable. Specifically, you have no assurance that the endotoxin levels of your intrathecal drug products are safe. a. Your firm does not release your intrathecal finished drug product based on endotoxin limit. For example, on 07/25/2022, your firm used a Sample Lot "7589/72322" for Sample ID "BUPHYDROFENTGABA" Value of r(o) (4)] EU/mL and "BUPBACFENTMORPH," yielding a Sample Value of [illegible] distributed to patients. b. Your firm does not control for endotoxins in intrathecal products. 1. Due to the absence of your ( (6) ) approximately [illegible] intrathecal [illegible] 06/02/2022 which were not tested. For example Patient [illegible] was dispensed [illegible]. 11. Non-sterile bulk drug substances (BDSs) and other components used to produce intrathecal [illegible]. Testing data. For example, Baclofen USP ([(15) (4)]) Lot 172103/G, does not have endotoxin testing data. Baclofen USP ([(6)]) used to produce Baclofen 1100 mcg/mL, Lot 07162022. C. Your firm inappropriately pools (combines) products into one sample unit during endotoxin testing. As such, the reported result is not a true representation of original drug product lots. For example, testing performed for Sample ID "7590/7600/072322" included multiple different finished compounded intrathecal drug products within one sample unit.
- 2
Inadequate media fill challenge
Your media fills were not performed under the most challenging or stressful conditions. Specifically, there is a lack of assurance that your firm can aseptically produce under the conditions used in your facility. Your firm utilizes a media fill kit for more complex preparations during sterile compounding. Injectable was produced on 06/08/2022.
- 3
ISO-5 uncertified dynamically
ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow in the ISO-5 hood in the compounding cleanroom was not verified under operational conditions during the certification performed on June 25, 2022. This hood is used by personnel in the production of sterile drug products, including products intended for intrathecal injection. Intrathecal parenteral preparations include bupivacaine, morphine, and hydromorphone. Items that potentially impact the unidirectional airflow such as a balance, transfer basket, vials, syringes, and [(6) ( ~ )] tubes were present.
- 4
Inadequate pressure differentials
Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your sterile compounding cleanroom did not meet the differential specification of (b)(4) in. W.G. or greater during verification testing per [illegible]. It is adjacent to a hallway which is neutral pressure and has no evidence of ISO certification. The compound room was measured as requiring a [illegible] reading using calibrated equipment as 0.0140. On the same day, viable air sampling was performed; samples were processed by (b)(4) under Sample IDs [illegible]. The room, which is pressure neutral to the hallway adjacent to the sterile compounding cleanroom, recovered both highly pathogenic organisms and CFU counts that exceeded the action limit for the sampling area. Recovered organisms include, but are not limited to, Trichophyton sp., Staphylococcus epidermidis, and Staphylococcus caprae. Your sterile compounding room is used to produce sterile products for intrathecal injection.
- 5
Use of non-pharmaceutical grade components
Non-pharmaceutical grade components are used. Specifically, your firm produces non-sterile drug products using components that are not intended for use in pharmaceutical preparations and are labeled in part, "For improved food preparation." Oral Solution, Lot 07212022, BUD 10/19/2022, was used on 07/21/2022 in the formulation of non-sterile drug products. For example, [illegible] was used to produce Dyclonine (Peppermint), 1%.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJun 9, 2023Carolina Infusion warning letter, June 9, 2023CDER · 301 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3015826782, newest first.
- Form 483, August 2026FDA record date Aug 18, 2026 · Posted Sep 22, 2026
- Form 483, January 2025Inspection ended Jan 24, 2025 · Posted Feb 28, 2025OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.