Carolina Infusion LLC

South Carolina

FEI 3015826782

FDA has 3 inspections on file for Carolina Infusion LLC in South Carolina (FEI 3015826782), from 2022 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Jan 24, 2025. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
3, 2022–2026
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
5 requests, latest Oct 8, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Lack of HEPA airflow and deficient sterility testing

      There is a lack of HEPA-filtered air and an inadequate HEPA filter coverage or airflow over the critical area to which sterile drug product is exposed. Specifically, on (b)(4), after the manufacture of tirzepatide for injection 26 mg/ml lot 08052026(b)(4) and tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4), the (b)(4) (b)(4) laminar flow hood (ISO-5) was operating with a pressure gauge reading of zero, indicating a failure to maintain the positive pressure required to protect the critical aseptic processing area from the influx of lesser quality air. You failed to use an appropriate anti-microbial preservative to prevent microbial proliferation within containers of multi-dose sterile drugs. Specifically, (b)(4) bulk stock solutions of drug products, such as tirzepatide, are stored in unclassified areas and repeatedly introduced into the ISO-5 environment over a (b)(4) period to draw up patient-specific syringes. This workflow repeatedly exposes the bulk container closure system to unclassified air during storage and introducing contamination risks with each re-entry. You are using (b)(4). This can only inhibit bacterial proliferation; it is not bactericidal and does not provide protection against mold contamination. Furthermore, your in-house sterility and endotoxin testing is deficient. Your firm is conducting sterility testing within the same ISO 5 hood simultaneously with the production of drug product intended to be sterile, such as tirzepatide. This is not appropriate for aseptic processing or laboratory testing. The in-house sterility and endotoxin test method development does not evaluate for product interference (e.g., from the use of (b)(4)). This calls into question the validity of your test results.

    2. Observation 2

      Dust-collecting surfaces and exposed insulation in cleanrooms

      The Cleanroom areas contain dust-collecting overhangs without adequate and frequent cleaning. Specifically, on 08/05/2026, visible dust was observed on the inside of the clean room door windowpane adjacent to the (b)(4) ISO-5 (b)(4) laminar flow hood in the non-hazardous compounding cleanroom which is used to produce sterile non-hazardous drug products. Throughout the cleanroom suites, doors and viewing windows feature decorative molding with ridges and ledges. These surfaces are not smooth, or easily cleanable, contributing to particulate accumulation and potential microbial contamination in close proximity to production activities for drug product intended to be sterile. Additionally, wall insulation was exposed and open to the mezzanine and warehouse area. This insulation was on the exterior of the generator room, the exterior of the ante room hallway, and the exterior of the hazardous compounding room. The mezzanine and stairs leading to the mezzanine were composed of particle generating wood particle board. In some locations, on the mezzanine, the air ducts were not connected to an exterior venting system.

    Show observations 3 to 10
    1. Observation 3

      Inadequate sterilization process with faulty pressure gauge

      Inadequate (b)(4) on (b)(4) used to sterilize drug products. Specifically, on (b)(4) after the manufacture of tirzepatide for injection 26 mg/ml lot 08052026(b)(4) and bulk tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4) we observed that the (b)(4) was not performed since the gauge used to test the (b)(4) appeared to be out of calibration and stuck on the pressure reading of approximately 18 PSI. This resulted in the following: - tirzepatide for injection 26 mg/ml lot 08052026(b)(4) was rejected on 8/6/2026. - bulk tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4) reprocessed on (b)(4).

    2. Observation 4

      Reprocessed drug product with deficient strength purity quality

      Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, the bulk tirzepatide/cyanocobalamin for injection 26 mg/2 mg per ml lot 08052026(b)(4) was reprocessed when the (b)(4) was not performed due to a pressure gauge malfunction. This reprocessing combined the contents of (b)(4) approximately (b)(4) bulk drug vials which were then (b)(4) and tested for endotoxin and sterility. This reprocessing was performed on (b)(4) and the beyond use date assigned was 9/19/2026.

    3. Observation 5

      Inadequate smoke studies under dynamic conditions

      Smoke studies were inadequately performed under dynamic conditions. Specifically, the smoke studies taken on 1/27/2025 in your ISO-5 (b)(4) laminar flow hoods and bio safety cabinets did not fully demonstrate laminar flow. These smoke study videos were 4 to 18 seconds long and recorded by (b)(4). The video does not show the air flow over the critical sterile drug product preparation areas and the air flow patterns for hoods that are located across from each other. Compounding room (b)(4) contains (b)(4) ISO 5 biosafety cabinets positioned facing each other, approximately 2-3 feet apart. One hood is designated for nuclear blood tagging, and the other is used for the production of testosterone cypionate injectable product intended to be sterile. No smoke study has been conducted to demonstrate that the airflow from one hood does not interfere with the airflow of the other. The smoke study videos also did not include the most dynamic conditions of use such as (b)(4).

    4. Observation 6

      Poor facility flow allows cross-contamination risks

      The facility is designed and/or operated in a way that permits poor flow of personnel or materials. The warehouse / material receiving and product shipping area was found to have the following deficiencies: - Open insulation and unfinished construction was observed in the warehouse on the wall between the cleanroom and warehouse. A recycling room at the back of the main warehouse / material receiving and shipping room is used for cleaning and storing the lead containers (pigs) used for shipping the radiopharmaceutical patient doses (syringes). In this recycle room, we observed that the firm is storing lead shipping containers (pigs) and radioactive waste such as Technetium Tc99m, Gallium Ga68 Netspot labeled containers, and Iodine I-123 capsules. The firm is disassembling (b)(4) radioactive generators used for production of Technetium Tc99m. Plastic containers, lead, metal and residue from these items was observed in this recycle room. Dead roach(es), dust and debris was also observed in this recycle room. - The firm lacks controls to prevent cross contamination of lead, lead particles, and other debris from the recycle room through the rest of the facility. A door connects the warehouse / material receiving and shipping room directly to the non-sterile compounding processing and pharmacy orders packaging room. A door connects the warehouse to the employee break room and front hallway, administrative area, and compounding area front entrance. These doors from the warehouse lack controls to prevent cross contamination from the recycle room, warehouse, and mezzanine areas from being introduced to the compounding non-sterile processing room. The only controls from preventing insanitary cross contamination to the main compounding cleanrooms and nuclear-pharmacy cleanrooms is the ante room.

    5. Observation 7

      Inadequate segregation of hazardous potent biohazardous operations

      Hazardous drugs and Highly potent drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. A. Specifically, testosterone compounding (a highly potent hormone), chemotherapy reconstitution (hazardous drugs), and blood radiolabeling (biohazardous material) are all performed within the same cleanroom (b)(4) using (b)(4) hoods in close proximity. There is no physical separation between the biohazardous blood handling area and the areas where non-blood products are handled. Furthermore, a shared supply table was observed containing materials for both testosterone compounding and blood radiolabeling activities, demonstrating inadequate dedication and segregation of equipment based on risk. Each of these high-risk activities requires fundamentally different decontamination approaches blood-borne pathogen decontamination, hazardous drug deactivation, and hormonal drug decontamination, respectively. The firm has not demonstrated through documented procedures or supporting evidence that the shared room, work surfaces, and equipment are adequately cleaned and decontaminated when transitioning between these activities. The performance of highly potent, hazardous, and biohazardous operations in the same unsegregated space, without demonstrated decontamination controls, represents a significant, unmitigated risk for cross-contamination whereby sterile drug products may have been rendered injurious to health. B. Specifically, the ante room gowning includes use of non-sterile lab personnel protective equipment including shoe covers, a short lab coat, hair net, face mask, hand washing, non-sterile gloves, and use of (b)(4) or (b)(4) disinfectants for the gloved hands. There is no method for detecting and controlling cross contamination such as swabbing and analytical lab testing for particles, lead particles, and other chemicals.

    6. Observation 8

      Lack of adequate environmental monitoring program

      Lack of and Inadequate routine environmental monitoring in the ISO 5 area and classified areas. Your staff stated they perform (b)(4) surface sampling within the ISO 5 and ISO 7 area after cleaning and disinfection. Sampling after cleaning does not accurately represent your production environment. Additionally, your staff also stated and demonstrated that when (b)(4) plates are unavailable, the firm's procedure is to use (b)(4) (b)(4), (b)(4) on a surface, and then (b)(4) that onto an (b)(4) plate as EM surface sampling. A (b)(4) alone will not efficiently lift or release microorganism from a (b)(4) surface on to an (b)(4) plate compared to a pre-saturated swab. This method also does not include the use of neutralizing buffer which is necessary to neutralize residual disinfectants. This calls into question the validity of your test results.

    7. Observation 9

      Blocked first air during aseptic manipulations

      Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, on 08/06/2026 during cleaning activities of the (b)(4) laminar flow hood ISO 5 (b)(4) in cleanroom (b)(4), the upper torso of a pharmacist was observed entering the ISO 5 hood, disrupting the unidirectional airflow intended to protect the sterile field.

    8. Observation 10

      Vermin evidence adjacent to production areas

      Vermin or other animals or evidence of their presence was observed in the areas adjacent to production areas. Specifically, on 08/05/2026, dead roaches were observed in the recycling room located at the back of the main warehouse, which is adjacent to areas with direct access to the compounding rooms. We observed each day of this inspection that bird feces were located on the ground outside your facility front door.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

    2. FDCA 501(a)(2)(A)

      Beta-lactam, hazardous, highly potent drugs, prevention of cross-contamination

      Hazardous drugs and Highly potent drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination.

    3. FDCA 501(a)(2)(A)

      Lack of disinfection, equipment/supplies from lower to higher quality air

      Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air.

    4. FDCA 501(a)(2)(A)

      Inadequate smoke studies

      Smoke studies were inadequately performed under dynamic conditions.

    5. FDCA 501(a)(2)(A)

      Lack of/inadequate, environmental monitoring

      Inadequate routine environmental monitoring in the ISO 5 area.

    Show 1 more citation
    1. FDCA 501(a)(2)(A)

      Exposed to lower quality air/ISO 5

      Materials were exposed to lower than ISO 5 quality air.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Endotoxin control failures

      Your firm produced drug products with materials that had not been verified to not contribute endotoxin contamination that may be objectionable. Specifically, you have no assurance that the endotoxin levels of your intrathecal drug products are safe. a. Your firm does not release your intrathecal finished drug product based on endotoxin limit. For example, on 07/25/2022, your firm used a Sample Lot "7589/72322" for Sample ID "BUPHYDROFENTGABA" Value of r(o) (4)] EU/mL and "BUPBACFENTMORPH," yielding a Sample Value of [illegible] distributed to patients. b. Your firm does not control for endotoxins in intrathecal products. 1. Due to the absence of your ( (6) ) approximately [illegible] intrathecal [illegible] 06/02/2022 which were not tested. For example Patient [illegible] was dispensed [illegible]. 11. Non-sterile bulk drug substances (BDSs) and other components used to produce intrathecal [illegible]. Testing data. For example, Baclofen USP ([(15) (4)]) Lot 172103/G, does not have endotoxin testing data. Baclofen USP ([(6)]) used to produce Baclofen 1100 mcg/mL, Lot 07162022. C. Your firm inappropriately pools (combines) products into one sample unit during endotoxin testing. As such, the reported result is not a true representation of original drug product lots. For example, testing performed for Sample ID "7590/7600/072322" included multiple different finished compounded intrathecal drug products within one sample unit.

    2. Observation 2

      Inadequate media fill challenge

      Your media fills were not performed under the most challenging or stressful conditions. Specifically, there is a lack of assurance that your firm can aseptically produce under the conditions used in your facility. Your firm utilizes a media fill kit for more complex preparations during sterile compounding. Injectable was produced on 06/08/2022.

    Show observations 3 to 5
    1. Observation 3

      ISO-5 uncertified dynamically

      ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow in the ISO-5 hood in the compounding cleanroom was not verified under operational conditions during the certification performed on June 25, 2022. This hood is used by personnel in the production of sterile drug products, including products intended for intrathecal injection. Intrathecal parenteral preparations include bupivacaine, morphine, and hydromorphone. Items that potentially impact the unidirectional airflow such as a balance, transfer basket, vials, syringes, and [(6) ( ~ )] tubes were present.

    2. Observation 4

      Inadequate pressure differentials

      Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, your sterile compounding cleanroom did not meet the differential specification of (b)(4) in. W.G. or greater during verification testing per [illegible]. It is adjacent to a hallway which is neutral pressure and has no evidence of ISO certification. The compound room was measured as requiring a [illegible] reading using calibrated equipment as 0.0140. On the same day, viable air sampling was performed; samples were processed by (b)(4) under Sample IDs [illegible]. The room, which is pressure neutral to the hallway adjacent to the sterile compounding cleanroom, recovered both highly pathogenic organisms and CFU counts that exceeded the action limit for the sampling area. Recovered organisms include, but are not limited to, Trichophyton sp., Staphylococcus epidermidis, and Staphylococcus caprae. Your sterile compounding room is used to produce sterile products for intrathecal injection.

    3. Observation 5

      Use of non-pharmaceutical grade components

      Non-pharmaceutical grade components are used. Specifically, your firm produces non-sterile drug products using components that are not intended for use in pharmaceutical preparations and are labeled in part, "For improved food preparation." Oral Solution, Lot 07212022, BUD 10/19/2022, was used on 07/21/2022 in the formulation of non-sterile drug products. For example, [illegible] was used to produce Dyclonine (Peppermint), 1%.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Oct 8, 2026.

  • Inspection ending Feb 28, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Sep 18, 2026. FDAgent holds no copy that FDA posted.

    1. Aug 31, 2026FDA-FOIA-2026-8401Form 483· 1 of 3 sitesRecords released
  • Inspection ending Jan 24, 2025OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jul 19, 2025FDA-FOIA-2025-8856Form 483· 1 of 3 sitesRecords released
    2. Jun 16, 2025FDA-FOIA-2025-7678Form 483· 1 of 9 sitesWithdrawn
    3. Mar 13, 2025FDA-FOIA-2025-2341Form 483· 1 of 2 sitesClosed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Oct 8, 2026FDA-FOIA-2026-9824Inspection recordsClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015826782 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015826782. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.