Octapharma Pharmazeutika Produktionsgesellschaft m.b.H.
Oberlaaer Strase 235, Vienna, Austria
FEI 3002809097DUNS 301119178
Company: Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. · Linked by exact D-U-N-S match (301119178) in FDA registration data
FDA has 5 inspections on file for Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. in Vienna, Austria (FEI 3002809097), from 2012 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. (D-U-N-S 301119178), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2012–2022
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Aug 13, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Facility pest control and environmental monitoring inadequate
Buildings used in the cGMP manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by contamination. Specifically, (b)(4) is not managed in a controlled manner to prevent, detect, clean and sanitize cGMP areas including classified areas (Grade (b)(4)). A. The plant (b)(4) period that occurs for (b)(4) Environmental and HEPA air filtration systems, monitoring is not conducted during the plant (b)(4) period. (b)(4) (b)(4) for controlled spaces are not maintained. Cleaning and plant (b)(4) occurs after this (b)(4) plant (b)(4) Cleaning validations are not assured as accurate and continuously valid as environmental (b)(4) are not collected and tested for during the plant (b)(4) period. B. The firm's (b)(4) control management is inadequate. The firm is not in control of the (b)(4) management data, this is managed by the (b)(4) and is available in a read only manner but the firm is not trending the locations of the (b)(4) and cannot assure that (b)(4) are not (b)(4) cGMP areas of production, (b)(4), or other areas. The firm reports aggregate numbers of (b)(4) every (b)(4), for example, in July 2022 there were: 13 (b)(4), 1 (b)(4), 24 other (b)(4), 86 (b)(4) in (b)(4) in production areas, and 1461 (b)(4) in (b)(4) in other areas. But these total number of (b)(4) are not readily or routinely monitored to distinguish cGMP areas including (b)(4) production, QC labs, and other critical areas, from (b)(4) and administration areas.
- Observation 2
Inadequate training and human error deviations
There is no assurance of effective training or accurate deviation root cause assignment for employees engaged in sampling, testing, data reporting and data review from the Quality Control Unit and Production Unit. The following deviations were reported to be due to human error or due in part to employees who were inadequately trained in the cGMP procedures. These include but are not limited to: Specifically, A. Deviation, TW#111834, dated 10-Sep-2019, (b)(4) Sample (b)(4) for storage at (b)(4) was not traceable because the sample was lost and could no longer be found. B. TW#136664, dated 12-Nov-2020, reports an incorrectly calculated result. The incorrect evaluation was not noticed during the raw data review. C. Deviation, TW#139567, dated 05-Jan-2021, (b)(4) result in (b)(4) due to suspected mislabeling. D. Deviation, TW#161584, dated 19-Feb-2022, wrong storage of sample Batch (b)(4) in (b)(4) E. Deviation, TW#163601, dated 29-Mar-2022, Result of molecular size distribution of (b)(4) of (b)(4) batches (b)(4) and (b)(4) was reported with wrong (b)(4) F. Deviation, TW#177497, dated 14-Sep-2022, Submission of a wrong result for total protein for (b)(4) to department (b)(4).
Show observations 3 to 7
- Observation 3
Unjustified production material holding time limits
Deviations from production material holding time limits are not justified. Specifically, There is a lack of written procedure describing in sufficient detail the storage of the materials taken out of the (b)(4) during production. Scientifically justified temperature hold time is lacking for the (b)(4) when taken out of the (b)(4) (less than (b)(4)). The time allowed that this material can be stored at (b)(4) ((b)(4)) before the (b)(4) is crushed and (b)(4) is not defined.
- Observation 4
Improper storage of QC reference standards
Deviations from written Quality Control test procedures for holding temperature and time of reference standards are not justified. Specifically, (b)(4) for laboratory testing are not properly stored to ensure the quality is intact. During the Quality walk through, (b)(4) of reference materials used for determination of (b)(4) (b)(4) (b)(4) with recommended storage condition of (b)(4)) and (b)(4) control (lot (b)(4) with recommended storage condition of (b)(4)) were left unattended on the bench at the (b)(4) (b)(4) and not maintained in a (b)(4) after being used for testing for more than (b)(4) (b)(4)
- Observation 5
Ineffective CAPAs for repeated deviations
Corrective actions and preventive actions (CAPAs) to discrepancy or the failure of a batch or any of its components to meet any of its specifications are not always effectively verified to prevent recurrent deficiencies. The following repeated deviations with the same or similar root cause were reported. Specifically, A. Temperature control deviations for (b)(4) (TW#136473, dated 09 November 2020; TW#153413, dated 17 September 2021; TW#153881, dated 27 September 2021; TW#153934, dated 28 September 2021; TW#154785; TW#159379, dated 11 January 2022; TW#165772, dated 09 May 2022). B. Final container products waiting for repacking stored at packaging line and stayed over routine procedures repeatedly (TW121137, dated 20 February 2020; TW#174998, dated 04 November 2022; and TW#1641796, dated 12 April 2022).
- Observation 6
Inadequate investigation of measles antibody OOS results
Failure to adequately assure approved levels of measles neutralizing antibody in the final product. The Out of Specifications (OOS) results were not sufficiently investigated for the root cause. Specifically, A total of Measles OOS routine batches occurred to multiple Immune Globulin Final Container products within two aggregate period 1) from July to Sept 2019 and 2) from August to Sept 2022. The root cause was attributed to the (b)(4) materials but the other factors and/or conditions were not accounted for, including but not limited to, blood collection center, differences in manufacturing among the firm's facilities where no such events occurred, and re-evaluation of the external laboratory for the test.
- Observation 7
Data integrity and archive audit deficiencies
(b)(4) data is not assured as exact, complete and secure from alteration, erasure or loss through keeping (b)(4) copy or alternate systems. related systems of or data (b)(4) (b)(4) are not checked for accuracy. Specifically, The firm's data management and data archive procedures are lack instructions to routinely perform annual data audit checks of the archived (b)(4) and (b)(4) cGMP analytical QC data and production batch records.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Aug 13, 2025. It asked for a Form 483.
Inspection ending Dec 16, 2022VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 13, 2025FDA-FOIA-2025-9738Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Octapharma Pharmazeutika Produktionsgesellschaft m.b.H.D-U-N-S 301119178
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. (D-U-N-S 301119178) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Octapharma ABStockholm, Sweden · FEI 30055599156 inspections6latestSep 19, 2023VAI1 warning letter, Apr 15, 2011
- Octapharma Dessau GmbHDessau-Roslau, Germany · FEI 30089236443 inspections3latestNov 8, 2024VAINone on file
- Octapharma Produktionsgesellschaft Deutschland mbHSpringe, Germany · FEI 30168553601 inspection1latestJun 11, 2024VAINone on file
- Octapharma S.A.S.Lingolsheim, France · FEI 30106001591 inspection1latestDec 6, 2022VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002809097 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002809097. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.