Skip to content

Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPG Form 483, December 2022

FDA issued this Form 483 to Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPG in Vienna, Austria (FEI 3002809097) at the end of a biologics inspection that ended December 16, 2022. It lists 7 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Dec 16, 2022
Biologics · Blood and Blood Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
1,410 days after the inspection
Facility
FEI 3002809097
Vienna, Austria

The 7 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Facility pest control and environmental monitoring inadequate

    Buildings used in the cGMP manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by contamination. Specifically, (b)(4) is not managed in a controlled manner to prevent, detect, clean and sanitize cGMP areas including classified areas (Grade (b)(4)). A. The plant (b)(4) period that occurs for (b)(4) Environmental and HEPA air filtration systems, monitoring is not conducted during the plant (b)(4) period. (b)(4) (b)(4) for controlled spaces are not maintained. Cleaning and plant (b)(4) occurs after this (b)(4) plant (b)(4) Cleaning validations are not assured as accurate and continuously valid as environmental (b)(4) are not collected and tested for during the plant (b)(4) period. B. The firm's (b)(4) control management is inadequate. The firm is not in control of the (b)(4) management data, this is managed by the (b)(4) and is available in a read only manner but the firm is not trending the locations of the (b)(4) and cannot assure that (b)(4) are not (b)(4) cGMP areas of production, (b)(4), or other areas. The firm reports aggregate numbers of (b)(4) every (b)(4), for example, in July 2022 there were: 13 (b)(4), 1 (b)(4), 24 other (b)(4), 86 (b)(4) in (b)(4) in production areas, and 1461 (b)(4) in (b)(4) in other areas. But these total number of (b)(4) are not readily or routinely monitored to distinguish cGMP areas including (b)(4) production, QC labs, and other critical areas, from (b)(4) and administration areas.

  2. 2

    Inadequate training and human error deviations

    There is no assurance of effective training or accurate deviation root cause assignment for employees engaged in sampling, testing, data reporting and data review from the Quality Control Unit and Production Unit. The following deviations were reported to be due to human error or due in part to employees who were inadequately trained in the cGMP procedures. These include but are not limited to: Specifically, A. Deviation, TW#111834, dated 10-Sep-2019, (b)(4) Sample (b)(4) for storage at (b)(4) was not traceable because the sample was lost and could no longer be found. B. TW#136664, dated 12-Nov-2020, reports an incorrectly calculated result. The incorrect evaluation was not noticed during the raw data review. C. Deviation, TW#139567, dated 05-Jan-2021, (b)(4) result in (b)(4) due to suspected mislabeling. D. Deviation, TW#161584, dated 19-Feb-2022, wrong storage of sample Batch (b)(4) in (b)(4) E. Deviation, TW#163601, dated 29-Mar-2022, Result of molecular size distribution of (b)(4) of (b)(4) batches (b)(4) and (b)(4) was reported with wrong (b)(4) F. Deviation, TW#177497, dated 14-Sep-2022, Submission of a wrong result for total protein for (b)(4) to department (b)(4).

  3. 3

    Unjustified production material holding time limits

    Deviations from production material holding time limits are not justified. Specifically, There is a lack of written procedure describing in sufficient detail the storage of the materials taken out of the (b)(4) during production. Scientifically justified temperature hold time is lacking for the (b)(4) when taken out of the (b)(4) (less than (b)(4)). The time allowed that this material can be stored at (b)(4) ((b)(4)) before the (b)(4) is crushed and (b)(4) is not defined.

  4. 4

    Improper storage of QC reference standards

    Deviations from written Quality Control test procedures for holding temperature and time of reference standards are not justified. Specifically, (b)(4) for laboratory testing are not properly stored to ensure the quality is intact. During the Quality walk through, (b)(4) of reference materials used for determination of (b)(4) (b)(4) (b)(4) with recommended storage condition of (b)(4)) and (b)(4) control (lot (b)(4) with recommended storage condition of (b)(4)) were left unattended on the bench at the (b)(4) (b)(4) and not maintained in a (b)(4) after being used for testing for more than (b)(4) (b)(4)

  5. 5

    Ineffective CAPAs for repeated deviations

    Corrective actions and preventive actions (CAPAs) to discrepancy or the failure of a batch or any of its components to meet any of its specifications are not always effectively verified to prevent recurrent deficiencies. The following repeated deviations with the same or similar root cause were reported. Specifically, A. Temperature control deviations for (b)(4) (TW#136473, dated 09 November 2020; TW#153413, dated 17 September 2021; TW#153881, dated 27 September 2021; TW#153934, dated 28 September 2021; TW#154785; TW#159379, dated 11 January 2022; TW#165772, dated 09 May 2022). B. Final container products waiting for repacking stored at packaging line and stayed over routine procedures repeatedly (TW121137, dated 20 February 2020; TW#174998, dated 04 November 2022; and TW#1641796, dated 12 April 2022).

  6. 6

    Inadequate investigation of measles antibody OOS results

    Failure to adequately assure approved levels of measles neutralizing antibody in the final product. The Out of Specifications (OOS) results were not sufficiently investigated for the root cause. Specifically, A total of Measles OOS routine batches occurred to multiple Immune Globulin Final Container products within two aggregate period 1) from July to Sept 2019 and 2) from August to Sept 2022. The root cause was attributed to the (b)(4) materials but the other factors and/or conditions were not accounted for, including but not limited to, blood collection center, differences in manufacturing among the firm's facilities where no such events occurred, and re-evaluation of the external laboratory for the test.

  7. 7

    Data integrity and archive audit deficiencies

    (b)(4) data is not assured as exact, complete and secure from alteration, erasure or loss through keeping (b)(4) copy or alternate systems. related systems of or data (b)(4) (b)(4) are not checked for accuracy. Specifically, The firm's data management and data archive procedures are lack instructions to routinely perform annual data audit checks of the archived (b)(4) and (b)(4) cGMP analytical QC data and production batch records.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.