Meiji Seika Pharma Co., Ltd. - Gifu Plant
2890, Kitagata; Kitagata-Cho, Motosu-Gun, Japan
FEI 3008927877DUNS 695400606
Company: Meiji Seika Pharma Co., Ltd. · Linked by exact D-U-N-S match (690541941) in FDA registration data
FDA has 3 inspections on file for Meiji Seika Pharma Co., Ltd. - Gifu Plant in Motosu-Gun, Japan (FEI 3008927877), from 2012 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant, Meiji Seika Pharma Co., Ltd. (D-U-N-S 690541941), has registered 2 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2012–2022
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit independence and validation approval failure
Failure to have a quality unit that is independent of production and fulfills quality assurance (QA) and quality control (QC) duties. Specifically, Your written procedure Roles and Responsibilities of Operations related to GMP, 40-60-018-00-00-V17, page 10 states the QA manager is responsible review of the validation protocol and reports. Page 11 of the procedure states Validation Manager is responsible for approving the validation protocol, validation report and releasing equipment for production. Validation Master Plan for the production of (b) (4) and related validation activities were approved by the Validation Manager.
- Observation 2
Inadequate controls over drug label printing
Failure to exercise sufficient controls over computerized systems to prevent unauthorized printing of drug substance labels. Specifically, a. Computer Tag. No. 10020792 used for printing (b) (4) and (b) (4) finished product and shipping labels does not require unique username and password to access for printing labels. b. Label room key control log did to capture access to the room during label printing operations for drug substance (b) (4) Lot (b) (4) on 5/16/2022.
Show observation 3
- Observation 3
Warehouse water damage and mold growth
Failure to properly maintain buildings and facilities used in the manufacture and storage of intermediates and API. Specifically, Raw Material warehouse No. 1 used to store raw materials and intermediates for the use in production of (b) (4) has water leak damage and mold growth on ceiling tile over (b) (4) lot number (b) (4)
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Sep 2, 2022VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2023-1308Form 483Closed
- Feb 13, 2025FDA-FOIA-2025-1449Form 483· 1 of 3 sitesClosed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2022-7498Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Meiji Seika Pharma Co., Ltd.D-U-N-S 690541941
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Meiji Seika Pharma Co., Ltd. (D-U-N-S 690541941) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Meiji Seika Pharma Co., Ltd.Kitakami, Japan · FEI 30029027763 inspections3latestJul 20, 2018VAINone on file
- Meiji Seika Pharmatech Co., Ltd.Kanagawa, Japan · FEI 3015407855Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3008927877 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3008927877. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.