Sumitomo Osaka Cement Co., Ltd Form 483, October 2023
FDA issued this Form 483 to Sumitomo Osaka Cement Co., Ltd in Kaizuka, Japan (FEI 3003943727) at the end of a drug inspection that ended October 27, 2023. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 5, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Oct 27, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 5, 2026
- 1,105 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Deficient cleaning validation for product changeover
Cleaning Validation Program is deficient, Specifically (b)(4) The firm manufactured and shipped API products for the US market in the past three years each with a different particle size as listed below: Product Name Product Type NDC (b)(4) [illegible] The firm performed three cleaning validations to establish successful product change over cleaning as detailed below for [illegible] Date of completion Result Content Reference A washing amount of (b)(4) or more is required. Validated 9/22/2014 CL-001 (b)(4) products -> (b)(4) products A washing amount of (b)(4) or more is required. Validated CL-001-4 6/5/2018 (b)(4) products -> (b)(4) products A washing amount of (b)(4) or more is required. Validated CL-001-5 2/26/2018 (b)(4) product -> (b)(4) product However, there is no assurance that the cleaning validation was successful. Approximately nine out of specification investigations were initiated after completion of the three successful cleaning validations for failure of Specific Surface Area (BET) results after cleaning as listed below: Name of the product Batch No. OOS Number Date of OOS Specific Surface Area (BET) Result m2/g Specification Root Cause (b)(4) [illegible] 3/14/2018 OOS18008 5/26/2018 OOS18014 6/4/2018 OOS18015 7/24/2018 OOS18018 Line cleaning insufficient 9/18/2018 OOS18026 11/15/2018 OOS18029 11/25/2018 OOS18030 2/26/2019 OOS19005 3/26/2019 OOS19006 No OOS investigations were initiated after 3/26/2019 and the quantity of discard was further increased to (b)(4) since June 11, 2019, if the cleaning results failed and was therefore not documented as OOS. However, the SOP for product changeover cleaning (GMP-SOP-M-006 revision 7, titled Product Switching Procedure Manual) was updated to include rejection of additional quantity of product on cleaning failure and made effective on 10/23/23 (the first day of inspection).
- 2
Deficient OOS investigations without CAPA
Out of Specification investigation (OOS) is deficient and further no CAPA is initiated to prevent recurrence. Specifically, 1. OOS investigation OOS21001 was initiated on 3/3/2021 to probe the failure of (b)(4) Assay (b)(4) to (b)(4)% in (b)(4) API batch (b)(4) % using Ion chromatograph. The root cause of failure was attributed to error in the first standard preparation without any scientific justification or comparison with historical area response obtained for standard. The firm prepared a second standard and calculated the result of the original sample, and the results met the specification (b)(4)%. The firm invalidated the original result based on passing result from the single new sample and new standard (second). No CAPA was initiated. 2. OOS investigation OOS22002 was initiated on 5/10/2022 to probe the failure of (b)(4) Assay (b)(4)% to (b)(4)% in (b)(4) API batch (b)(4) using Ion chromatograph. The root cause of failure was attributed to error in standard preparation. The firm invalidated the original result based on passing result [illegible] standard preparation. The CAPA (CP-22001) did not consider error in the weighing of the standard and instead stated that the failure is possibly due to spillage of standard solution while preparation without any scientific evidence. 3. OOS investigation OOS23001 was initiated on 1/30/2023 to probe the failure of [illegible] (b)(4) to [illegible] in (process validation batch) against a specification of [illegible] API batch (b)(4). No root cause was identified and the original sample from the lab and fresh sample from the (b)(4) warehouse was reanalyzed and the results met the specification. The original result was invalidated and no CAPA was initiated.
- 3
Supplier COA not validated with confirmatory testing
Reports of analysis from component suppliers are accepted without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, (b)(4) the raw material utilized in the manufacturing of Raw material suppliers of (b)(4) API (b)(4) were qualified without establishing for US (b)(4) and complete reliability of supplier's certificates of analysis (COA) through confirmatory testing. Results of vendor and firm were not comparable for multiple quality attributes. Your written procedure for supplier qualification process, SOP GMP-SOP-S-017, revision 2 on Purchasing / subcontractor management procedure manual is deficient and does not specify the number of batches required to be tested for verification of vendor COA during vendor qualification of raw materials. Additionally, your current practice of reduced testing from one vendor does not include verification of (b)(4) assay, a critical quality attribute and instead only an identification test for verification of weight variation of the (b)(4) is performed using x-ray fluorescence and [illegible] to identification of (b)(4). The acceptance and release criteria from a second vendor includes only (b)(4) and no other critical quality attribute for (b)(4) is verified for release. The confirmation of (b)(4) current tests performed for release of (b)(4) does not follow the tests recommended in (b)(4) USP monograph. The change control (KC-152) permitting reduced testing for acceptance of (b)(4) was approved on December 8, 2022. However, it was observed that the firm was conducting reduced testing [illegible] batches as early as January 2022 (for (b)(4)) and July 2022 (for (b)(4)) Batches.
- 4
Quality unit responsibilities not fully followed
The roles and responsibilities of the quality unit is not fully followed. Specifically, 1. During the review of OOS investigations, it was observed that about ten confirmed OOS was reported for failure of specific surface area (SSA-BET) in API batches and the root cause was attributed to fluctuation in (b)(4) of raw material. However, no CAPA was initiated. 2. During the review of OOS investigations, it was observed that about 13 confirmed OOS was reported for failure of specific surface area (SSA-BET) in API batches and the root cause was attributed to insufficient cleaning of lines after product changeover cleaning. However, no CAPA was initiated. 3. (b)(4) The BET method validated in 2014 (VDR-A-001) for testing of specific surface area in (b)(4) API shipped for US failed to meet the acceptance criteria. The firms QA Manager (from [illegible] site) stated that the method was not revalidated (validation report A-001) until August of 2023 because the firm did not have any OOS associated with the test. However, it was observed that about ten confirmed OOS was reported for failure of specific surface area (SSA-BET) in API batches. 4. Deviation DV22002 and DV22003 was initiated for excursions in humidity (74%) for (b)(4) and for temperature and humidity (35.8C and 70.4% RH) for (b)(4) in the 25C/60%RH stability chamber. However, no CAPA was initiated. 5. The analytical method for the raw material (b)(4) used in the manufacturing of (b)(4) API is not verified. The firm does not perform testing of assay and instead confirm assay with the COA of supplier to ensure if the results meet the firms' specification. 6. The operating (b)(4) of the (b)(4) Id # APK-002 utilized in (b)(4) of raw material to manufacture (b)(4) (b)(4) and (b)(4) API is (b)(4) to (b)(4). However, the calibration of the old (b)(4) was performed between (b)(4) to (b)(4) (Certificate# FK 610003-1-8) and between (b)(4) to (b)(4) (Certificate# FK 600446-1-8) in July 2022 for the new (b)(4) in September 2022, thus not covering the entire operating range. 7. The firm does not monitor appearance and assay of (b)(4) (critical quality attributes) on stability samples of all (b)(4) API for US instead monitors residue on ignition, conductivity and specific surface area. The firm has shipped approximately (b)(4) API batches to US since 2019. 8. Your Training Procedure GMP-SOP-S-005 states to include CGMP training in the (b)(4) training plan. However, no documentation was available for any employee of the firm for the year 2021 and 2022. 9. No method equivalency is established between the (b)(4) XRF method (X-ray fluorescence) and the USP Ion Chromatography method used for the determination of (b)(4) in (b)(4) raw material.
- 5
Inadequate audit trail review for BET analyzer
Review of audit trail for analytical data generated by your firm is inadequate. Specifically, Review of the electronic audit trails from the Specific surface area measuring machine (BET) - Macsorb HM-model 1201 (ID-RK062 for API samples and ID-RK131 for raw material samples) indicated repeated events of Measurement error, Measurement interruption, Measurement warning and File delete. For example, during the test runs, the following incidents were observed between September 2022 and September 2023: Instrument ID/ Errors RK131 RK062 Measurement error 2 6 Measurement interruption 4 [illegible] Measurement warning 5 [illegible] File delete 1 [illegible] File move 15 [illegible] File rename 18 [illegible] File save with different name [illegible] However, your quality unit did not initiate deviation for these instances to assess what may have caused these events. You also failed to investigate what those interruptions are and why the files were deleted. Your Audit Trail Review - SOP GMP-SOP-S-046 is deficient in that it does not cover system errors such as the ones listed in the table above. This limits your ability to review, document, and investigate all electronic data and is a gap in your Data Integrity Program.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.