Linhai Tianyu Pharmaceutical Co., Ltd. Form 483, September 2023
FDA issued this Form 483 to Linhai Tianyu Pharmaceutical Co., Ltd. in Taizhou, China (FEI 3013345425) at the end of a drug inspection that ended September 15, 2023. It lists 7 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 15, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 1,155 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Deficient equipment cleaning and hold time procedures
Written procedures are deficient for the cleaning and maintenance of equipment used in the manufacturing, processing, packing, or holding of a drug substance. Specifically, Your firm's clean hold time study and evaluation report (Confirmation report on the validity of the clean retention time of the crude (b) (4) production equipment GP-EV-PR-3-211203; Evaluation Report on Reasonableness of CHT of (b) (4) Area Equipment GR-EV-PR-3-220805) that are applicable for drug substances and intermediates, including (b) (4) conclude a (b) (4) clean hold time in (b) (4) following a (b) (4) clean. Your firm's Equipment Cleaning Management Procedure SMP-PR-011 requires a (b) (4) clean for (b) (4) beyond this (b) (4) hold time that is valid for (b) (4) Your firm's Cleaning Management Procedure (SMP-PR-011) and clean hold time study and evaluation (GP-EV-PR-3-211203, GR-EV-PR-3-220805) are deficient because they do not include adequate scientific justification for the (b) (4) clean hold time following a (b) (4) clean after (b) (4) clean. For example, we reviewed Equipment Operational Logbooks FOM-GDL-035-01 for 2022.05.09~2022.08.10 and 2022.08.18~2022.08.28 for (b) (4) (b) (4) 215 in Workshop (b) (4) On July 4, 2022, your firm completed a (b) (4) clean after a production campaign of (b) (4) (b) (4) later, your firm completed a (b) (4) clean on (b) (4) per your firm's Cleaning Management Procedure (SMP-PR-011). On August 16, 2022, your firm began a (b) (4) batch production campaign for (b) (4) an intermediate used in the manufacturing of drug substance (b) (4) for the China and Europe market. Your firm has no scientific justification that confirms a (b) (4) clean following a (b) (4) clean hold time is sufficient on (b) (4) equipment used between production campaigns of (b) (4) different products.
- 2
Facilities and equipment not adequately maintained
Facilities and equipment used in the manufacturing of drug substances are not adequately maintained. Specifically, During our facility walk-through on 9/11/2023, we observed the following conditions in Workshops (b) (4) and (b) (4) that are used for drug substance manufacturing of (b) (4) and other drug substances and intermediates intended for the U.S. market: Workshop (b) (4) (b) (4) 315 with three ~2 feet segments of broken pipe insulation laying near utility pipes that connect to the (b) (4) station and (b) (4) tank (b) (4) 318 with multiple reddish/brown areas on the ground and a puddle of water under the utility pipes that connect to the (b) (4) station and the (b) (4) tank (b) (4) 322 with reddish/brown areas surrounding utility pipes that run through the floor and connect to the (b) (4) station and (b) (4) tank Area between (b) (4) 214 and (b) (4) 215 with 1) a (b) (4) ~3-feet by 2-feet by 2-inch pan-like item placed under the utility pipes that connect to the (b) (4) station and (b) (4) tanks 2) a ~2 feet by 1 foot reddish/brown area of peeling floor under utility pipes that connect to the (b) (4) station 3) a drooping clear coil with reddish/brown residue that connects to utility pipes that connect to the (b) (4) station (b) (4) 217 with a drooping clear coil with reddish/brown residue that carries (b) (4) to utility pipes that connect to the (b) (4) station and (b) (4) tank (b) (4) with a detached floor area of ~1 foot by 1 foot with reddish/brown residue directly next to the (b) (4) tank with a pipe running through it Workshop (b) (4) (b) (4) 416 with (b) (4) insulation on the outside of the (b) (4) station while production of (b) (4) batch (b) (4) was occurring Your firm uses Equipment Maintenance Management Procedure SMP-EN-003 that requires (b) (4) patrol and documentation of facilities and equipment used in the production of drug substances in Workshops (b) (4) and other workshops. Your firm did not adequately document (b) (4) patrols nor the inadequate status of equipment and pipelines in Workshop (b) (4) within the Equipment Inspection Record FOM-SMP-EN-003-03.03 for Workshop (b) (4) that is required per the Equipment Maintenance Management Procedure SMP-EN-003.
- 3
Inadequate OOS investigations and CAPAs
Written records of investigation into unexplained discrepancies and the failure of a batch or any of its components to meet specification do not always include the conclusions and follow-up. Specifically, Investigations initiated and performed by your Quality Unit in response to Out of Specification results, laboratory events, and market complaints related to intermediates and API manufactured by your firm are not always scientifically sound or comprehensive with respect to root cause determination. Additionally, Corrective Action/Preventive Action (CAPAs) as a result of investigations are not always comprehensive to address root causes documented to have been performed. For Example: A. -On or around 01/14/2021, OOS-205301-21001 was initiated for intermediate (b) (4) batch number (b) (4) (intermediate for (b) (4) drug substance) for other single impurity with results as (b) (4)% and (b) (4)% versus specification of NMT (b) (4)%. Your firm's investigation determined the root cause to be "the tester did not change gloves after testing the (b) (4) solution and directly prepared the (b) (4) sample solution, resulting in contamination". -On or around 01/21/2021, OOS-10501-21001 was initiated for drug substance (b) (4) (b) (4) batch number (b) (4) for (b) (4) impurity (b) (4) with result as (b) (4) ppb versus specification of LOD (4) ppb. Your firm's investigation determined the root cause to be "the tester did not wear gloves when weighing back, returning the control and transferring the test solution, resulting in contamination of the test solution". -On or around 06/08/2021, OOS-10501-21003 was initiated for intermediate (b) (4) intermediate for (b) (4) drug substance), batch number (b) (4) for test item (b) (4) standard with result as (b) ppm versus specification of NMT (4) ppm. Your firm's investigation determined the root cause to be "the inspector did not change his gloves when testing (b) (4) resulting in some bottle caps being contaminated with (b) (4)" -On or around 01/01/2022, OOS-10501-22001 was initiated for drug substance (b) (4) (b) (4) batch number (b) (4) 6-month accelerated stability test for (b) (4) impurity (b) (4) with result as (b) (4) ppb versus a specification of LOD (4) ppb. Your firm's investigation determined the root cause to be "the bottle cap used for the test did not differentiate between the use of samples and controls, and the tester got the (b) (4) contaminated bottle cap, resulting in the test solution being contaminated with (b) (4)" For all OOS investigations performed by your firm, the assignable root cause was determined without performing hypothesis studies and without scientific justification. B. Starting from 04/01/2021 to 07/07/2022, your firm has initiated 2 OOT and 7 OOS investigations for 11 batches with respect to intermediate product (b) (4) for test specifications for any individual impurity (NMT (b) (4)%) and/or total impurities (NMT (b) (4)%). All batches involved were said to be destroyed as a result. Subsequent investigations performed by your firm's QC and R&D units have resulted in the identification of a root cause for formation of the impurity, however no adequate CAPA has been implemented to address this root cause. Per your firm's personnel, current action plan, should another OOS occur, is to destroy the batch. C. During our review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" chromatographic data. Your firm documented these interrupted injections due to a power outage via investigation no. DR-3-22003R, dated 02/27/2022, showing that no chromatograms had been generated for (b) (4) drug substance batch numbers (b) (4). However, during the investigation, the interrupted sample injections were not adequately documented and/or investigated, in that your firm did not verify the incomplete data to evaluate if the interrupted sequence chromatogram for abnormalities. D. Complaint No. CH-3-23004, dated 02/20/2023 wa
Shortened here; the PDF has the full text.
- 4
Laboratory records not contemporaneous or complete
Laboratory records are not completed contemporaneously and do not include complete data derived from all tests to assure compliance with established specifications and standards. Specifically, A. Electronic and physical laboratory records data review are not completed contemporaneously by your QC reviewers. During our walkthrough of your QC laboratory data review room on 09/11/23, I observed your QC analyst/reviewer checking off boxes on a form titled "Checklist of Electronic Data" for approximately 5 analytical batch records for (b) (4) testing of (b) (4) API via Ion Chromatography test, one after another, without any software opened for review. In all, we counted approximately 18 analytical test records for six batches which the analyst confirmed to have performed during the observed review process from above. Your analyst stated that they had reviewed the electronic data on the software in another room approximately one hour before. B. Microbiology laboratory records and usage logbooks are not completed contemporaneously by your analysts. During our walkthrough of your microbiology laboratory, we observed a QC analyst filling out a form titled "Preparation and Use Records of Control Medium" for preparation of (b) (4) controlled media used for system suitability reference for testing of (b) (4) water. Items observed in the process of being filled out included, but not limited to, reagents used, quantity of reference media and (b) (4) water used, stirring to dissolve operations, dispensing into a bottle operation, and (b) (4) operations. Per your analyst, they had finished preparation of the (b) (4) controlled media prior to my arrival to the room.
- 5
No stability-indicating testing program
There is no written testing program designed to assess the stability characteristics of drug substances and intermediates. Specifically, the assay and related substance test methods for intermediate (b) (4) used for stability testing are not stability indicating, where they can detect the change with time in chemical, physical or microbiological properties of the intermediate drug substance so that the content of active ingredients and degradation products can be accurately measured without interference. As a result, the validity of the stability of the process cannot be verified, in that your firm is not able to monitor results during stability studies in order to assure safety, efficacy and quality for your intermediate drug substance.
- 6
Inadequate controls over computerized systems
Appropriate controls are not exercised over computers or related systems to assure that changes in quality control records are instituted only by authorized personnel. Specifically, GMP related computerized systems and equipment have not been validated/qualified to demonstrate the suitability of computer hardware and software to perform assigned tasks. Your firm appears to have performed Performance Verification and data integrity assessments for Empower 3 software, however the verification and assessments do not evaluate the consistent performance of the software/equipment over a specified period and operating environment. For Example, during our review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" chromatographic data. Your firm has not demonstrated full understanding of the different types of communication errors and circumstances which may lead to a "Data incomplete" or Bad Checksum/Data Missing chromatography considering the relationship between the Empower application and database server, Empower RDS servers, internet connection, Empower LAC/Es, and the instruments connected to LAC/Es. This discrepancy in your firm's ability to review, document, and investigate all electronic data is a gap in your Data Integrity Program.
- 7
Inadequate QC oversight of electronic data review
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, Supervisory oversight over the laboratory electronic systems and data is deficient. Per your firm's data review procedure, Quality Control (QC) personnel perform review electronic test data for all analytical batch records using an approved review procedure and checklist for HPLC/GC network equipment. This review process does not appear to be adequate, in that all potential data generated during that specific review period for that product are not reviewed. For example, your firm utilizes up to five different software's for testing of intermediate and API products on HPLC and GC equipment, which include, Empower 3, Openlab CDS, LabSolutions, MassHunter. There is no software dedicated to testing of a particular intermediate or API, as the analyst may use whichever software is available at the time of the test. There is no adequate reconciliation of all generated electronic test data during the review process for HPLC/GC network equipment.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.