Skip to content

Linhai Tianyu Pharmaceutical Co., Ltd.

Provincial Chemical And Medical Raw Materials Base, No. 15 Donghai 5th Ave. Provincial Chem., Taizhou, China

FEI 3013345425DUNS 528185508

FDA has 2 inspections on file for Linhai Tianyu Pharmaceutical Co., Ltd. in Taizhou, China (FEI 3013345425), from 2019 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Apr 19, 2019. No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Linhai Tianyu Pharmaceutical Co., Ltd. (D-U-N-S 528185508).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2019–2023
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jul 1, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Deficient equipment cleaning and hold time procedures

      Written procedures are deficient for the cleaning and maintenance of equipment used in the manufacturing, processing, packing, or holding of a drug substance. Specifically, Your firm's clean hold time study and evaluation report (Confirmation report on the validity of the clean retention time of the crude (b) (4) production equipment GP-EV-PR-3-211203; Evaluation Report on Reasonableness of CHT of (b) (4) Area Equipment GR-EV-PR-3-220805) that are applicable for drug substances and intermediates, including (b) (4) conclude a (b) (4) clean hold time in (b) (4) following a (b) (4) clean. Your firm's Equipment Cleaning Management Procedure SMP-PR-011 requires a (b) (4) clean for (b) (4) beyond this (b) (4) hold time that is valid for (b) (4) Your firm's Cleaning Management Procedure (SMP-PR-011) and clean hold time study and evaluation (GP-EV-PR-3-211203, GR-EV-PR-3-220805) are deficient because they do not include adequate scientific justification for the (b) (4) clean hold time following a (b) (4) clean after (b) (4) clean. For example, we reviewed Equipment Operational Logbooks FOM-GDL-035-01 for 2022.05.09~2022.08.10 and 2022.08.18~2022.08.28 for (b) (4) (b) (4) 215 in Workshop (b) (4) On July 4, 2022, your firm completed a (b) (4) clean after a production campaign of (b) (4) (b) (4) later, your firm completed a (b) (4) clean on (b) (4) per your firm's Cleaning Management Procedure (SMP-PR-011). On August 16, 2022, your firm began a (b) (4) batch production campaign for (b) (4) an intermediate used in the manufacturing of drug substance (b) (4) for the China and Europe market. Your firm has no scientific justification that confirms a (b) (4) clean following a (b) (4) clean hold time is sufficient on (b) (4) equipment used between production campaigns of (b) (4) different products.

    2. Observation 2

      Facilities and equipment not adequately maintained

      Facilities and equipment used in the manufacturing of drug substances are not adequately maintained. Specifically, During our facility walk-through on 9/11/2023, we observed the following conditions in Workshops (b) (4) and (b) (4) that are used for drug substance manufacturing of (b) (4) and other drug substances and intermediates intended for the U.S. market: Workshop (b) (4) (b) (4) 315 with three ~2 feet segments of broken pipe insulation laying near utility pipes that connect to the (b) (4) station and (b) (4) tank (b) (4) 318 with multiple reddish/brown areas on the ground and a puddle of water under the utility pipes that connect to the (b) (4) station and the (b) (4) tank (b) (4) 322 with reddish/brown areas surrounding utility pipes that run through the floor and connect to the (b) (4) station and (b) (4) tank Area between (b) (4) 214 and (b) (4) 215 with 1) a (b) (4) ~3-feet by 2-feet by 2-inch pan-like item placed under the utility pipes that connect to the (b) (4) station and (b) (4) tanks 2) a ~2 feet by 1 foot reddish/brown area of peeling floor under utility pipes that connect to the (b) (4) station 3) a drooping clear coil with reddish/brown residue that connects to utility pipes that connect to the (b) (4) station (b) (4) 217 with a drooping clear coil with reddish/brown residue that carries (b) (4) to utility pipes that connect to the (b) (4) station and (b) (4) tank (b) (4) with a detached floor area of ~1 foot by 1 foot with reddish/brown residue directly next to the (b) (4) tank with a pipe running through it Workshop (b) (4) (b) (4) 416 with (b) (4) insulation on the outside of the (b) (4) station while production of (b) (4) batch (b) (4) was occurring Your firm uses Equipment Maintenance Management Procedure SMP-EN-003 that requires (b) (4) patrol and documentation of facilities and equipment used in the production of drug substances in Workshops (b) (4) and other workshops. Your firm did not adequately document (b) (4) patrols nor the inadequate status of equipment and pipelines in Workshop (b) (4) within the Equipment Inspection Record FOM-SMP-EN-003-03.03 for Workshop (b) (4) that is required per the Equipment Maintenance Management Procedure SMP-EN-003.

    Show observations 3 to 7
    1. Observation 3

      Inadequate OOS investigations and CAPAs

      Written records of investigation into unexplained discrepancies and the failure of a batch or any of its components to meet specification do not always include the conclusions and follow-up. Specifically, Investigations initiated and performed by your Quality Unit in response to Out of Specification results, laboratory events, and market complaints related to intermediates and API manufactured by your firm are not always scientifically sound or comprehensive with respect to root cause determination. Additionally, Corrective Action/Preventive Action (CAPAs) as a result of investigations are not always comprehensive to address root causes documented to have been performed. For Example: A. -On or around 01/14/2021, OOS-205301-21001 was initiated for intermediate (b) (4) batch number (b) (4) (intermediate for (b) (4) drug substance) for other single impurity with results as (b) (4)% and (b) (4)% versus specification of NMT (b) (4)%. Your firm's investigation determined the root cause to be "the tester did not change gloves after testing the (b) (4) solution and directly prepared the (b) (4) sample solution, resulting in contamination". -On or around 01/21/2021, OOS-10501-21001 was initiated for drug substance (b) (4) (b) (4) batch number (b) (4) for (b) (4) impurity (b) (4) with result as (b) (4) ppb versus specification of LOD (4) ppb. Your firm's investigation determined the root cause to be "the tester did not wear gloves when weighing back, returning the control and transferring the test solution, resulting in contamination of the test solution". -On or around 06/08/2021, OOS-10501-21003 was initiated for intermediate (b) (4) intermediate for (b) (4) drug substance), batch number (b) (4) for test item (b) (4) standard with result as (b) ppm versus specification of NMT (4) ppm. Your firm's investigation determined the root cause to be "the inspector did not change his gloves when testing (b) (4) resulting in some bottle caps being contaminated with (b) (4)" -On or around 01/01/2022, OOS-10501-22001 was initiated for drug substance (b) (4) (b) (4) batch number (b) (4) 6-month accelerated stability test for (b) (4) impurity (b) (4) with result as (b) (4) ppb versus a specification of LOD (4) ppb. Your firm's investigation determined the root cause to be "the bottle cap used for the test did not differentiate between the use of samples and controls, and the tester got the (b) (4) contaminated bottle cap, resulting in the test solution being contaminated with (b) (4)" For all OOS investigations performed by your firm, the assignable root cause was determined without performing hypothesis studies and without scientific justification. B. Starting from 04/01/2021 to 07/07/2022, your firm has initiated 2 OOT and 7 OOS investigations for 11 batches with respect to intermediate product (b) (4) for test specifications for any individual impurity (NMT (b) (4)%) and/or total impurities (NMT (b) (4)%). All batches involved were said to be destroyed as a result. Subsequent investigations performed by your firm's QC and R&D units have resulted in the identification of a root cause for formation of the impurity, however no adequate CAPA has been implemented to address this root cause. Per your firm's personnel, current action plan, should another OOS occur, is to destroy the batch. C. During our review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" chromatographic data. Your firm documented these interrupted injections due to a power outage via investigation no. DR-3-22003R, dated 02/27/2022, showing that no chromatograms had been generated for (b) (4) drug substance batch numbers (b) (4). However, during the investigation, the interrupted sample injections were not adequately documented and/or investigated, in that your firm did not verify the incomplete data to evaluate if the interrupted sequence chromatogram for abnormalities. D. Complaint No. CH-3-23004, dated 02/20/2023 wa

      Shortened here; the PDF has the full text.

    2. Observation 4

      Laboratory records not contemporaneous or complete

      Laboratory records are not completed contemporaneously and do not include complete data derived from all tests to assure compliance with established specifications and standards. Specifically, A. Electronic and physical laboratory records data review are not completed contemporaneously by your QC reviewers. During our walkthrough of your QC laboratory data review room on 09/11/23, I observed your QC analyst/reviewer checking off boxes on a form titled "Checklist of Electronic Data" for approximately 5 analytical batch records for (b) (4) testing of (b) (4) API via Ion Chromatography test, one after another, without any software opened for review. In all, we counted approximately 18 analytical test records for six batches which the analyst confirmed to have performed during the observed review process from above. Your analyst stated that they had reviewed the electronic data on the software in another room approximately one hour before. B. Microbiology laboratory records and usage logbooks are not completed contemporaneously by your analysts. During our walkthrough of your microbiology laboratory, we observed a QC analyst filling out a form titled "Preparation and Use Records of Control Medium" for preparation of (b) (4) controlled media used for system suitability reference for testing of (b) (4) water. Items observed in the process of being filled out included, but not limited to, reagents used, quantity of reference media and (b) (4) water used, stirring to dissolve operations, dispensing into a bottle operation, and (b) (4) operations. Per your analyst, they had finished preparation of the (b) (4) controlled media prior to my arrival to the room.

    3. Observation 5

      No stability-indicating testing program

      There is no written testing program designed to assess the stability characteristics of drug substances and intermediates. Specifically, the assay and related substance test methods for intermediate (b) (4) used for stability testing are not stability indicating, where they can detect the change with time in chemical, physical or microbiological properties of the intermediate drug substance so that the content of active ingredients and degradation products can be accurately measured without interference. As a result, the validity of the stability of the process cannot be verified, in that your firm is not able to monitor results during stability studies in order to assure safety, efficacy and quality for your intermediate drug substance.

    4. Observation 6

      Inadequate controls over computerized systems

      Appropriate controls are not exercised over computers or related systems to assure that changes in quality control records are instituted only by authorized personnel. Specifically, GMP related computerized systems and equipment have not been validated/qualified to demonstrate the suitability of computer hardware and software to perform assigned tasks. Your firm appears to have performed Performance Verification and data integrity assessments for Empower 3 software, however the verification and assessments do not evaluate the consistent performance of the software/equipment over a specified period and operating environment. For Example, during our review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" chromatographic data. Your firm has not demonstrated full understanding of the different types of communication errors and circumstances which may lead to a "Data incomplete" or Bad Checksum/Data Missing chromatography considering the relationship between the Empower application and database server, Empower RDS servers, internet connection, Empower LAC/Es, and the instruments connected to LAC/Es. This discrepancy in your firm's ability to review, document, and investigate all electronic data is a gap in your Data Integrity Program.

    5. Observation 7

      Inadequate QC oversight of electronic data review

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, Supervisory oversight over the laboratory electronic systems and data is deficient. Per your firm's data review procedure, Quality Control (QC) personnel perform review electronic test data for all analytical batch records using an approved review procedure and checklist for HPLC/GC network equipment. This review process does not appear to be adequate, in that all potential data generated during that specific review period for that product are not reviewed. For example, your firm utilizes up to five different software's for testing of intermediate and API products on HPLC and GC equipment, which include, Empower 3, Openlab CDS, LabSolutions, MassHunter. There is no software dedicated to testing of a particular intermediate or API, as the analyst may use whichever software is available at the time of the test. There is no adequate reconciliation of all generated electronic test data during the review process for HPLC/GC network equipment.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 1, 2026. It asked for a Form 483.

  • Inspection ending Sep 15, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 1, 2026FDA-FOIA-2026-6259Form 483· 1 of 2 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Linhai Tianyu Pharmaceutical Co., Ltd.D-U-N-S 528185508

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013345425 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013345425. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.