Almon Healthcare Private Limited
Sk Industrial Estate Plot No 4, Behind Kerala Gidc, Ahmedabad, India
FEI 3030509366DUNS 929877680
FDA has one inspection on file for Almon Healthcare Private Limited in Ahmedabad, India (FEI 3030509366). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below. Three FOIA requests have asked FDA for this inspection's 483.
FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is ALMON HEALTHCARE PRIVATE LIMITED (D-U-N-S 929877680).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2026
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Aug 14, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- 66-40Red List
- Matched on FDA’s firm name and street address
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit failure to ensure CGMP compliance
Failure of your quality unit to exercise its responsibility to ensure the active pharmaceutical ingredient (API) and intermediates manufactured at your facility are in compliance with CGMP. a. Your Quality unit lacked adequate control over the shredder used in the QA document control room. On February 9, 2026, a shredder was found three-fourths full of shredded quality related documents. One partially recognizable fragment contained a batch manufacturing record number [illegible]. Furthermore, your QA unit completely deviated from SOP "Document destruction procedure SOP/QA/043" by failing to maintain a logbook documenting when and what quality documentation was destroyed and the name and signature of the person who destroyed the GMP documents. b. There is no QA oversight on batch issuance record to document who requested, received, returned and accepted the batch record. For example, QA issued a batch manufacturing record (BMR) for (b)(4) on January 22, 2026, with no documentation for requested, received and returned by sign and date. However, QA has the completed BMR that was signed and released by QC and QA signature to proceed to the next stage. c. Your QA does not review microbial specification results as part of batch manufacturing release. Your firm manufactured (b)(4) and tested finished products for analytical and microbiological testing; however, batch release was based only on analytical results, treating microbiology testing as additional testing not required for product release. (b)(4) batches (b)(4) were reviewed and released to the US customer with analytical (b)(4) specifications only. When the customer requested microbiology testing data, your QC/QA revised the COA to include microbiology specification results, which were not reviewed and approved by QA at the time of release. In the batch release check list QC and QA marked N/A for microbial analysis approved/complies as per specification. d. Your QA did not initiate deviation investigations for production and facility maintenance departments failing to complete work activities inside the cleanrooms [illegible]. This resulted in approximately [illegible] gaps [illegible] between the [illegible] and the floor [illegible] towards the ceiling [illegible] gap at the topside middle of the [illegible] and wall, and [illegible] around the [illegible] that facilitates free air flow from outside the facility, creating potential for contamination. Your QA and production allowed manufacturing operations for the past six months inside these rooms, including batches (b)(4) (b)(4) to the US market. e. Your firm's finished product sampling SOP "Sampling procedure of intermediate and finished good, SOP/QC/015" was inadequately written to provide instructions for sampling. While the procedure specifies withdrawing sample quantities per analysis method from each container in equal amounts, it fails to specify sampling locations for different container sizes. f. Your firm's SOP "Packing material and standard test procedure, STP No. STP/PM0013" was not adequately written to provide instruction for conducting drop impact test on the packing [illegible] container and drop the container. The procedure says fill containers to its nominal capacity with (b)(4) container but fails to clarify whether the nominal amount equals the finished product fill weight to ensure proper impact resistance evaluation. g. Your QA failed to control GMP documents for non-GMP use. Your QA issued a control document "Sample distribution, reconciliation & destruction sheet, Annexure Number: SOP/QC/067-01, issue copy No. 20, date, January 6, 2026", however, this controlled document was used as scribbling paper in the QA document control room.
- Observation 2
Non-validated non-stability-indicating test methods
Your firm failed to use validated and stability-indicating test procedures. Your firm failed to use stability indicating methods to test active pharmaceutical ingredients (b)(4) batches shipped to the US market when assigning retest dates of (b)(4). The stability indicating aspects of in-house methods (b)(4) used for USP (b)(4) and the compendial method for (b)(4) were not evaluated through method validation and forced degradation studies to ensure no chromatographic co-elution of impurity peaks with the active peak. The following batches were on stability studies: Batch No. Manufacturing date Stability study start date (b)(4) [illegible].
Show observations 3 to 11
- Observation 3
Unsound specifications without method validation verification
Failure to ensure that all specifications are scientifically sound and appropriate to ensure that your raw materials and API conform to established standards of quality and purity. a. Your firm failed to conduct method validation for the in-house method and verification for compendial methods for the following KSM and APIs. Test Description STP number KSM (b)(4) [illegible]. b. Analytical method verification carried out by your firm for (b)(4) related substances by HPLC using outside laboratory's validated method failed to identify all the unknown related substances in the finished API and stability samples. Your firm is using this analytical method (STP [illegible]/005) for testing related substances in the finished API and stability samples.
- Observation 4
Inadequate computerized system data integrity controls
Your firm failed to exercise sufficient controls over computerized systems to prevent unauthorized access or changes to data and failure to have adequate controls to prevent omission of data. a. HPLC and GC data from instruments GC HS QC/001, HPLC QC/002, QC/024 and QC/0025 covering January 2024 to June 2025 saved on standalone computer were backed up only once in June 2025 to an external hard drive without assurance of correct data was saved and backed up. Additionally, the firm has not established a process to retrieve and verify the reliability of the backed-up HPLC and IR data saved from June 2025 till February 2026 in the server. b. On February 10, 2026, an analyst was observed using another analyst's username and password to log into OpenLabs HPLC software from computer in room (b)(4) (Instrument Lab [illegible]) during data (b)(4) audit review for data in the presence of the Executive QA and QC Manager. c. Your firm's Executive QA is the administrator for HPLC and IR software and data backup due to staff shortage. d. Your firm failed to restrict privileges to employees for accessing Raw material specification word document (b)(4) Specification No. SPC/RM066, Revision No.: 01) used by QA. This document is not locked to prevent any changes. Further your firm provided cut, copy, rename and delete provisions to this document.
- Observation 5
Failure to maintain cleanroom buildings and facilities
Failure to properly maintain buildings and facilities used in the manufacture of intermediates and API. a. Your firm failed to maintain cleanroom conditions that prevent contamination from the outside environment (b)(4) processing room (b)(4)-001 and (b)(4) for the US market. During the walkthrough of the facility on February 10, 2026, the following gaps were observed around the (b)(4) bottom and the gap between the (b)(4) (b)(4)-001: approximately (b)(4) gap on the top right-hand corner between the (b)(4) floor (b)(4) towards the ceiling. These gaps create free airflow (b)(4) gap at the topside middle of the (b)(4) from outside the facility into the clean room with potential for contaminants and dust particles to enter. According to the Executive QA, (b)(4)-001 was installed in August 2025 and the facility manufactured and shipped (b)(4) batches of (b)(4) to the US in the market. Your firm initiated change control CC/PR/25/008 to install the (b)(4) production area; however, no evaluation and/or impact assessment was performed for products manufactured inside this room for the past six months. b. Room (b)(4) adjacent to (b)(4) had a makeshift wall (approximately (b)(4) (b)(4) constructed in the left side corner to install [illegible]-001. This created a gap of approximately (b)(4) between the makeshift wall and the room wall, facilitating free air flow from outside the facility into the cleanroom with potential for contaminants and dust particles to enter. This makeshift wall has been in place since August 2025. Additionally, it was also noted that your firm turned the air handling unit (AHU) on and off based on production activities. According to your Executive QA, a minimum of (b)(4) is required to recover the ISO 8 (Class D) condition. However, the recovery time was not mentioned in the test report. APIs, including (b)(4) inside this room, shipped to the US market were (b)(4). c. The following areas in the cleanroom facility for processing and packing API were maintained in unsanitary condition: i. (b)(4) area (clean room): Walls, floors and ceiling showed apparent (b)(4) (b)(4) stains. The (b)(4) was unclean with blocked (b)(4) (b)(4) stains. The door to the intermediate processing area showed apparent rust and (b)(4) was not properly closed. Cleaning logs showed (b)(4) cleaning on February 10, 2026. ii. (b)(4) stains were visible on walls and ceiling. An incomplete construction area in the corner next to (b)(4)-001 (b)(4) contained apparent dirt like material. iii. (b)(4) clean room: apparent stains were present on walls. An incomplete construction area containing apparent dirt-like material.
- Observation 6
Failure to clean equipment preventing contamination
Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and API. a. Your firm uses a (b)(4) (b)(4) to [illegible]. No usage or cleaning logbook exists for this [illegible]. This is used in the manufacturing of different APIs including (b)(4) (b)(4) (b)(4) for the US market. b. On February 9, 2026, a (b)(4) (b)(4) (002) on them [illegible] floor showed apparent [illegible] particle deposits along lid, gasket, substance was observed draining and deposited at the bottom despite the status board indicating "empty and cleaned" and the usage logbook showing batch-to-batch cleaned on February 2, 2026. c. On February 9, 2026, 103 [illegible] room showed apparent (b)(4) (b)(4) (b)(4) rust and particle deposits on the exterior of the [illegible] and particle deposits inside the (b)(4) (b)(4) (b)(4) on the bottom. Usage log showed the last batch to batch cleaning (b)(4) (b)(4) occurred on February 4, 2026.
- Observation 7
No identity testing or supplier qualification
Failure to test the identity of each batch of incoming production material and appropriately qualify suppliers to rely upon their Certificate of Analysis. Your firm failed to perform identity testing on raw materials (b)(4) accepting them based solely on supplier COAs. Your QA Executive confirmed that the supplier for (b)(4) intentionally mislabels and ships (b)(4) [illegible] batches received since 2024. Your firm used this untested [illegible] No identity testing has been performed on (b)(4) containers as (b)(4) in manufacture of (b)(4) and shipped to the US market. According to your SOP/QA/002 (Vendor approval/Development), the suppliers for common raw material other than KSM are directly added to the provisional vendor list without qualification. For example, your firm used (Goods receive note, supplier COA and the firm COA show the material name as (b)(4) material (b)(4) received on October 25) A.R. No. [illegible] in the manufacture of (b)(4) code (b)(4) (b)(4) (b)(4) and shipped to (b)(4) batches the US market.
- Observation 8
Failure to monitor water system quality
Failure to monitor the (b)(4) water system to ensure that water is of appropriate quality. Your firm lacks both preventive maintenance and sanitization programs for the (b)(4) water system, failing to ensure appropriate water quality for API manufacturing and cleaning equipment/utensils that directly come in contact with APIs. Water testing is limited to collection from the (b)(4) water collection at production point-of-use locations, with testing conducted against (b)(4) and (b)(4) in-house specifications including (b)(4).
- Observation 9
No cleaning validation for non-dedicated equipment
Failure to adequately validate written procedures for the cleaning and maintenance of equipment. Your firm has not performed cleaning validation studies for non-dedicated manufacturing equipment (b)(4) including (b)(4). Your firm manufactures APIs including (b)(4) (b)(4) (b)(4) for the US market. Your Executive QA stated that the cleaning verification was carried out with rinse samples and swab testing of the selected equipment, however cleaning validation was not performed.
- Observation 10
Insufficient reserve samples retained
Failure to retain sufficient quantities of reserve sample to conduct analyses. Your firm failed to collect enough (b)(4) full API reserve samples to conduct (b)(4) specification analyses. Your firm collects only (b)(4) sample, which is adequate for conducting (b)(4) analytical test. There is no scientific justification for and microbiological test (b)(4) (b)(4) sample for each lot of API collecting only [illegible]. Your firm also sent (b)(4) retain samples to contract testing laboratory for (b)(4) (b)(4) batches (b)(4) analysis.
- Observation 11
Stability containers do not simulate market container
Failure to store stability samples in containers that simulate the market container. (b)(4) container bags used for stability samples to establish retest dates for APIs including (b)(4) for the US market. Your Executive QA confirmed that the firm uses (b)(4) bags used for bags as the (b)(4) container for API stability studies, which do not simulate the (b)(4) commercial packaging.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 14, 2026. Each one asked for a Form 483.
Inspection ending Feb 13, 2026OAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 14, 2026FDA-FOIA-2026-7888Form 483· 1 of 5 sitesRecords released
- May 22, 2026FDA-FOIA-2026-5223Form 483Records released
- May 19, 2026FDA-FOIA-2026-5081Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsAlert on fda.gov
Date published 2026-06-09
- FDA’s entry
- Almon Healthcare Private Limited · Sk Industrial Estate Plot No 4, Behind Kerala Gidc, Ahmedabad, Gujarat INDIA
- FDA’s inspection record for FEI 3030509366
- Almon Healthcare Private Limited · Sk Industrial Estate Plot No 4, Behind Kerala Gidc, Ahmedabad, India
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
15 products
- 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
- 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
- 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
Show 12 more products
- 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
- 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- ALMON HEALTHCARE PRIVATE LIMITEDD-U-N-S 929877680
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3030509366 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3030509366. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.