Sun Pharmaceuticals Medicare Ltd. Form 483, September 2025

FDA issued this Form 483 to Sun Pharmaceuticals Medicare Ltd. in Halol, Gujarat (FEI 3002957541) at the end of a drug inspection that ran from September 8 to September 19, 2025. It lists 3 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Dec 29, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Sep 8–19, 2025
Drugs · CDER
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Dec 29, 2025
101 days after the inspection
Facility
FEI 3002957541
Halol, Gujarat

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Deficient aseptic practices and process validation

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, followed, or including adequate validation of the sterilization process. Specifically, A. On 09/13/2025, I (EL) observed the aseptic assembly, set-up, and filling of (b)(4) (b)(4) Injection, U.S. Batch (b)(4) in Block (b)(4) vial filling line (b)(4) Room (b)(4) The following deficient aseptic practice was observed. a) The operator appeared unfamiliar with the sterile connection process. He did not sanitize his hands or use appropriate aseptic technique in performing sterile connections. Specifically, During the critical S2S (sterile-to-sterile) connection between the sterile product transfer tank (in Grade B) and the filling machine (in Grade A), I observed that without sanitizing his hands, the operator grabbed the sterile connector end (in (b)(4) cover) of the manifold tubing from the Grade A filling line. He attempted but failed to hang the tubing over the (b)(4) RABS (b)(4) He next took the tubing with the sterile connector from the transfer tank. He held both tubing in one hand, using a sterile pair of forceps he removed the (b)(4) cover from each connector including the cover he previously handled with his unsanitized hand. He proceeded to use his unsanitized hands opening the (b)(4) (cover) from each sterile connector to perform the sterile to sterile connection. He sanitized his hands only after completing the S2S connection. Your firm's MF video shows operator sanitized his hands prior to conducting the S2S connection. b). Items exposed to a less controlled Grade B environment were not sanitized prior to introducing them to a highly controlled (b)(4) RABS Grade A area. Also, operators without sanitizing hands were seen conducting Grade A activities. Specifically, The (b)(4) were (b)(4) sterilized in (b)(4) bags. During installation of the sterile (b)(4) I observed the (b)(4) wrapper was removed in the Grade B filling room, exposing the (b)(4) wrapper containing the sterile (b)(4) to the Grade B air. I observed that without sanitizing the (b)(4) wrapper surfaces, the (b)(4) bag was transferred into the Grade A filling line area via (b)(4) I observed the operator staged his unsanitized hands (b)(4) to receive the bag, proceeded to open the (b)(4) bag inside the Grade A area, and remove the sterile (b)(4) from the bag. I then observed the operator touched the Grade A side of the (b)(4) with his unsanitized hands in order to find the correct orientation for installation. All (b)(4) for the Grade A filling line were installed this way. Your firm's MF video shows operator sanitized his hands prior to conducting (b)(4) installation. c). There is a lack of validation for the (b)(4) sterilization cycle. The (b)(4) are cleaned and sterilized between batches. Each (b)(4) receives up to (b)(4) cycles. However, the (b)(4) sterilization cycles are not validated. When watching the (b)(4) installation, I observed some (b)(4) appeared (b)(4) I observed operators having great difficulty (b)(4) SOP 010727, section 5.1.2.9 requires immediate reporting if any abnormality observed during (b)(4) installation. Management confirms there have been no reporting of (b)(4) which indicates possible deterioration of the (b)(4) d). During the assembly and set-up operations, operators did not sanitize their hands before (b)(4) (b)(4) the Grade A filling area. Hands were sanitized after (b)(4) the (b)(4) RABS (b)(4) while they were already inside the Grade A filling line. Also, during hand sanitization, I observed sterile (b)(4) was sprayed near the Grade A EM settling plates and active air sampler, possibly contaminating the (b)(4) media. e). Sterile articles were transferred to the Grade B filling room using a (b)(4) LAF (b)(4) Operators did not sanitize their hands before reaching inside the Grade A (b)(4) LAF (b)(4) Also, the interior Grade A side of the (b)(4) LAF (b)(4) that had been exposed to the Grade B environm

    Shortened here; the PDF has the full text.

  2. 2

    Deficient environmental and personnel monitoring system

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. During review of the environmental and personnel monitoring (EM and PM), the following was noted: A. From 01/2023 to date, a total of (4) batches were rejected due to EM or PM excursions. (4) of the rejections involved manufacturing Block (b)(4) PM excursions (Action limits for Grade A: (b)(4) Grade B: (4) cfu/plate or NMT (b)(4) cfu (b)(4) gown locations). Review of monitoring records from 01/2023 to date showed a negative trend of Block (b)(4) PM where a total of 122 PM Grade B action limit excursions were noted (including 5 Grade A excursions). Microorganisms isolated included Gram positive skin flora species (i.e., Staphylococcus, Micrococcus), Bacillus species, Gram negative species (i.e., Pseudomonas, Moraxella, Vibro), and mold species (i.e., Aspergillus, Penicillium). As of to date, an effective comprehensive CAPA has yet to be achieved. B. There is a lack of adequate justification to classify the manufacturing Block (b)(4) filling line (b)(4) vial sealing (b)(4) RABS as Grade C (Action limits: Passive air (b)(4) cfu/plate, Active air (b)(4) cfu/m3). This (b)(4) line manufactures sterile (b)(4) (b)(4) mg/vial). In addition, you stated that Grade A air is supplied to the (b)(4) RABS and the non-viable particle count (NVPC) is monitored per Grade A standard. However, no NVPC is monitored during batch production. Only pre or post batch NVPC is monitored. C. There is a lack of adequate justification to classify the manufacturing Block (b)(4) filling line (b)(4) vial sealing (b)(4) RABS as Grade B (Action limits: Passive air (b)(4) cfu/plate, Active air (b)(4) cfu/m3). This (b)(4) line manufactures sterile commercial products for the U.S. market. In addition, you stated that Grade A air is supplied to the (b)(4) RABS and NVPC is monitored per Grade A standard. However, no NVPC is monitored during batch production. Only pre or post batch NVPC is monitored.

  3. 3

    Inadequate investigations of discrepancies and batch failures

    There is a failure to thoroughly review any unexplained discrepancy, the failure of a batch or any of its components to meet any of its specifications, whether or not the batch has been already distributed. Specifically, A. FAR/25/001 was submitted on 01/17/2025 regarding bacteriological contamination observed in the aseptic process simulation (APS) Batch (b)(4) On 01/13/2025, APS Batch (b)(4) was conducted in Block (b)(4) Line (Room (b)(4) On 01/16/2025, positive growth of Staphylococcus hominis was observed in all (b)(4) vials before incubation. Deviation was initiated on 01/16/2025. Your investigation (No. 2061578) identified that (b)(4) integrity failure being the root cause for the APS failure. However, you did not conduct investigation into the reason(s) for the (b)(4) failure, i.e., (b)(4) damage, improper (b)(4) system (b)(4) mimic a failure, or incomplete (b)(4) ranges (b)(4). Your CAPA included the use of (b)(4). Instead of (b)(4) a total of (b)(4) (b)(4) are used. From 06/21/2024 (last successful APS) to 01/13/2025, a total of (b)(4) batches of aseptically filled (b)(4) Suspension USP were manufactured in Block (b)(4) (b)(4) Line (b)(4). A total of (b)(4) batches are currently in the U.S. market and within expiry. Your investigation is inadequate in that it did not include investigation into (b)(4) integrity failure. Your CAPA is inadequate in that it failed to assure the observed (b)(4) failure will not occur again. B. The Block (b)(4) vial filling line (b)(4) is used to aseptically fill products for (b)(4) (b)(4) APS requalification Batch (b)(4) was filled on 07/05/2024. After (b)(4) of the incubation, positive growth was observed in (b)(4) container units. After (b)(4) of the incubation, growth was seen in (b)(4) container units. Your investigation identified that incorrect size of (b)(4) stoppers being the root cause for contamination. The contaminating microorganisms included Kocuria rhizophila, Kocuria palustris, Aspergillus tubingensis/vadensis, Staphylococcus haemolyticus, Staphylococcus epidermidis, Micrococcus luteus, Brachybacterium conglomeratum/paraconglomeratum, and Brachybacterium squillarum. Your investigation is inadequate in that you did not look into what caused the ingress of contaminating microorganism. Your management stated the contamination was likely introduced from the Grade C (Action limits: Passive air (b)(4) cfu/plate, Active air (b)(4) cfu/m3) area surrounding the sealing Grade B (b)(4) RABS. Your CAPA included using the correct size (b)(4) stoppers. However, you failed to thoroughly investigate how the ingress of microbial contamination occurred. In 12/2024, without adequate justification, you downgraded the vial sealing (b)(4) RABS from Grade B to Grade C, further exposing the sealing operation to a lesser controlled environment. Your MF failure investigation and CAPA actions were inadequate to assure product sterility. C. Review of MF failure investigations revealed containers that showed positive growth were immediately removed and tested for microbial identification prior to completion of the (b)(4) incubation. Removal of containers prior to the (b)(4) incubation does not allow for the detection of slow-growing microorganisms, damaged microorganisms, or microorganisms having different temperature requirement sufficient time to recover and proliferate.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3002957541, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.