Skip to content

Emcure Pharmaceuticals Limited Form 483, February 2025

FDA issued this Form 483 to Emcure Pharmaceuticals Limited in Pune, India (FEI 3005782879) at the end of a drug inspection that ended February 25, 2025. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 25, 2025
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 20, 2026
602 days after the inspection
Facility
FEI 3005782879
Pune, India

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate equipment cleaning and maintenance procedures

    Failure to establish and follow adequate written procedures for cleaning and maintenance of equipment to prevent contamination or carryover of materials. Specifically, during a walkthrough of your facility on 19-20 February 2025, I observed multiple deficiencies related to equipment cleaning, cleaning validation, and maintenance, indicating a lack of adherence to established procedures. For example, but not limited to the following: A. [illegible] Labeled "clean" per procedure "KMF-601/24, Procedure for Cleaning of Equipment, Accessories, and Auxiliaries, Effective Date: 16 Dec 2024", yet exhibited visible residues [illegible] (b)(4) particulates (b)(4) liquid [illegible] material, and (b)(4) [illegible] Dirty Hold Time without corrective action [illegible] and [illegible] ng was performed beyond the [illegible] (b)(4) swab tests confirmed contamination [illegible] There is no supporting data exists for DHT or Clean Hold Time (CHT) limits for Type (b)(4) or [illegible] An operator performed cleaning without completing required training per procedure "AQA-081/04, Training, Effective Date: 10 Sep 2024". B. Cleaning Validation Deficiencies: Your firm failed to validate the cleaning procedures for [illegible] vessels, and receiver tanks used in the manufacture of [illegible] USP, despite documented residues [illegible] post-cleaning. Your firm lacks cleaning validation which establishes residue limits for cleaning validation in collection receivers, transfer vessels, and equipment used in all API manufacturing Blocks for Type (b)(4) [illegible] Improper use of gaskets and [illegible] (b)(4) gaskets wrapped in tape were observed across multiple (b)(4) despite [illegible] EM-020/01 [illegible] Management of 022" prohibiting such use. tape is not a cleanable surface and can lead to contamination. Your firms Deputy General Manager, [illegible] tape, but continued to use the tape. Cleaning procedures lack objective cleaning criteria and defined cleaning pressure requirements (despite procedure "EOP-032/04, Procedure for Operation and Cleaning of (b)(4) and (b)(4) Effective Date: 29 Jun 2023" specifying (b)(4) kg/cm2). C. Maintenance and Equipment Integrity Issues: (b)(4) showed physical deterioration (paint chips, rust, peeling) and [illegible] maintenance "KEM-008/06, Preventive Maintenance for [illegible] (b)(4) Effective Date: 06 Aug 2024" did not require inspection for such damage. (b)(4) with numerous [illegible] and (b)(4) #1402 had (b)(4) dents; cleaning validation did not address potential residue in hard-to-clean areas nor incorporate dent study results.

  2. 2

    Inadequate training documentation and verification

    Failure to ensure proper documentation and verification of training records. Specifically, your firm failed to adequately document and verify training records for personnel involved in manufacturing, equipment, and cGMP training. For example, - The current training system does not require individual trainees to electronically sign and verify their completion of ANY group training. Training records for ALL group trainings are entered by the trainer for all attendees without individual authentication or verification. There is no supporting documentation ensuring that each trainee received and understood the training.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.