Emcure Pharmaceuticals Limited
Plot D-24 Midc, Kurkumbh Industrial Area, Taluka Daund, Pune, India
FEI 3005782879DUNS 677602452
Company: Emcure Pharmaceuticals Limited · Linked by exact D-U-N-S match (916921919) in FDA registration data
FDA has 6 inspections on file for Emcure Pharmaceuticals Limited in Pune, India (FEI 3005782879), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. Three FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant, Emcure Pharmaceuticals Limited (D-U-N-S 916921919), has registered 3 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2025
- 0 OAI · 6 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Jun 2, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning and maintenance procedures
Failure to establish and follow adequate written procedures for cleaning and maintenance of equipment to prevent contamination or carryover of materials. Specifically, during a walkthrough of your facility on 19-20 February 2025, I observed multiple deficiencies related to equipment cleaning, cleaning validation, and maintenance, indicating a lack of adherence to established procedures. For example, but not limited to the following: A. [illegible] Labeled "clean" per procedure "KMF-601/24, Procedure for Cleaning of Equipment, Accessories, and Auxiliaries, Effective Date: 16 Dec 2024", yet exhibited visible residues [illegible] (b)(4) particulates (b)(4) liquid [illegible] material, and (b)(4) [illegible] Dirty Hold Time without corrective action [illegible] and [illegible] ng was performed beyond the [illegible] (b)(4) swab tests confirmed contamination [illegible] There is no supporting data exists for DHT or Clean Hold Time (CHT) limits for Type (b)(4) or [illegible] An operator performed cleaning without completing required training per procedure "AQA-081/04, Training, Effective Date: 10 Sep 2024". B. Cleaning Validation Deficiencies: Your firm failed to validate the cleaning procedures for [illegible] vessels, and receiver tanks used in the manufacture of [illegible] USP, despite documented residues [illegible] post-cleaning. Your firm lacks cleaning validation which establishes residue limits for cleaning validation in collection receivers, transfer vessels, and equipment used in all API manufacturing Blocks for Type (b)(4) [illegible] Improper use of gaskets and [illegible] (b)(4) gaskets wrapped in tape were observed across multiple (b)(4) despite [illegible] EM-020/01 [illegible] Management of 022" prohibiting such use. tape is not a cleanable surface and can lead to contamination. Your firms Deputy General Manager, [illegible] tape, but continued to use the tape. Cleaning procedures lack objective cleaning criteria and defined cleaning pressure requirements (despite procedure "EOP-032/04, Procedure for Operation and Cleaning of (b)(4) and (b)(4) Effective Date: 29 Jun 2023" specifying (b)(4) kg/cm2). C. Maintenance and Equipment Integrity Issues: (b)(4) showed physical deterioration (paint chips, rust, peeling) and [illegible] maintenance "KEM-008/06, Preventive Maintenance for [illegible] (b)(4) Effective Date: 06 Aug 2024" did not require inspection for such damage. (b)(4) with numerous [illegible] and (b)(4) #1402 had (b)(4) dents; cleaning validation did not address potential residue in hard-to-clean areas nor incorporate dent study results.
- Observation 2
Inadequate training documentation and verification
Failure to ensure proper documentation and verification of training records. Specifically, your firm failed to adequately document and verify training records for personnel involved in manufacturing, equipment, and cGMP training. For example, - The current training system does not require individual trainees to electronically sign and verify their completion of ANY group training. Training records for ALL group trainings are entered by the trainer for all attendees without individual authentication or verification. There is no supporting documentation ensuring that each trainee received and understood the training.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jun 2, 2026. Each one asked for a Form 483.
Inspection ending Feb 25, 2025VAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Jun 2, 2026FDA-FOIA-2026-5469Form 483Records released
- Jun 21, 2025FDA-FOIA-2025-7920Form 483· 1 of 10 sitesWithdrawn
- Mar 4, 2025FDA-FOIA-2025-1948Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Emcure Pharmaceuticals LimitedD-U-N-S 916921919
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Emcure Pharmaceuticals Limited (D-U-N-S 916921919) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Emcure Pharmaceuticals LimitedAhmedabad, India · FEI 30145950233 inspections3latestMay 15, 2026VAINone on file
- Emcure Pharmaceuticals LimitedSurendranagar, India · FEI 30221755651 inspection1latestOct 10, 2025NAINone on file
- EMCURE PHARMACEUTICALS LIMITEDPune, India · FEI 30066438601 inspection1latestMar 31, 2023NAINone on file
Other FEIs recorded as Emcure Pharmaceuticals Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Emcure Pharmaceuticals LimitedFEI 3016408148Gandhinagar, India
Last inspected 2022-06-24NAI
Emcure Pharmaceuticals LimitedFEI 3005151215Pune, India
Last inspected 2019-02-20OAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3005782879 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3005782879. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.