Medi-Fare Drug Pharmaceutical Compounding LLC Form 483, June 2025

FDA issued this Form 483 to Medi-Fare Drug Pharmaceutical Compounding LLC in Blacksburg, South Carolina (FEI 3009925820) at the end of a drug inspection that ended June 6, 2025. It lists 9 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Aug 7, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 6, 2025
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Aug 7, 2025
62 days after the inspection
Facility
FEI 3009925820
Blacksburg, South Carolina

The 9 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Sterility contamination prevention lacking

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. I visually observed contaminated / stained HEPA filter affecting ISO 5 hood in addition to hood [illegible] hoods, also have apparent contamination / stains. To date, no investigation has been opened regarding this apparent contamination. B. You lack a scientifically established qualification process regarding your media fill unit inspections. You have not demonstrated, via training and qualification, that personnel can accurately and repeatedly detect failing units. C. You rejected lot of repacked Proparacaine HCl 0.5% due to sterile caps coming off of your (b)(4) syringes during production. You documented this via INC-24-014 which records the use of caps lot [illegible]. These caps had not been scientifically evaluated prior to use to include actions including but not limited to change control, process validation and / or media fills. After this batch rejection, you documented CAPA-24-005 which includes the use of a new vendor cap. While CAPA-24-005 requires container closure integrity testing of approximately [illegible] units, it does not require such actions as process validation, stability testing and / or media fills.

  2. 2

    Cleaning and disinfection system deficient

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, A. I observed apparent white colored residue and apparent brown or red colored stains on your work surfaces in your ISO 5 hood. The apparent white colored residue is also apparent throughout your ISO 5 environment affecting approximately all hoods. The design with the approximate of your working surfaces offers hard to clean surfaces. To date, [illegible] investigation has been opened regarding this apparent contamination. B. You have failed to confirm and maintain the cleanliness of your ISO 5 environments. 1. You use [illegible] to generate smoke during your airflow pattern evaluations. You have not performed testing to support the adequacy of your cleaning procedures for the presence or absence of [illegible] after you have cleaned and sanitized your ISO 5 environments. 2. I observed cleaning and sanitizing activities using [illegible] on 5/19/2025 which included ISO 5 hood. I observed your ISO 5 surfaces began to [illegible] no later than (b)(4) and become fully dry at approximately (b)(4) post cleaning and sanitizing activities. Your written procedures require you to maintain contact times of (b)(4) for [illegible].

  3. 3

    Facility flow and pressure controls deficient

    The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. The design of your facility allows for operations to include material flows directly between unclassified areas and your ISO 7 sterile compounding room, "Room [illegible]". Specifically, materials flow from your non-classified "Prep Room" to your ISO 7 compounding room, "Room [illegible]" and from "Room [illegible]" to your non-classified room, "Quarantine Area". Non-classified areas lack continuous monitoring of differential pressures as well as non-viable particles. B. Air pressure differential limit setpoint alarms and alarm delays are not scientifically established nor monitored regarding your ISO 7 room where you produce sterile drug product(s). You did not establish real-time setpoint limit alarms according to your written SOPs such that your SOP requires differential pressures of [illegible] W.C. Your actual alarm limits are [illegible] W.C. Furthermore, you established alarm delays of approximately [illegible] per your electronic monitoring system and / or vendor as well as your Quality Director. Your written SOPs lack reference to any air differential alarm delays.

  4. 4

    Environmental monitoring system inadequate

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Personnel and environmental monitoring during and after your aseptic connection as well as throughout aseptic production is not scientifically performed. 1. The system by which you conduct personnel monitoring is not scientifically established. I observed personnel enter your ISO 5 environment with their hands and arms. You do not currently routinely perform personnel monitoring regarding production personnel forearms. 2. I observed aseptic operators perform finger-tip personnel monitoring after performance of the aseptic connection unit step which includes bulk filling. However, multiple glove changes occurred during this process. B. Non-Viable Particle (NVP) monitoring is conducted in the ISO 5 hoods. This NVP monitoring is not continuously performed. Furthermore, the firm produces sterile drug products in multiple ISO 5 hoods concurrently and only owns one NVP monitoring device.

  5. 5

    Supplier reports accepted without validation

    Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, you have not certified that water is sterile and nonpyrogenic whereby it is accompanied by a valid COA to ensure the reliability of the supplier's Certificate of Analysis. Water is used in the production of sterile drug products to include Fentanyl [illegible] 10 mcg/mL in [illegible] bags.

  6. 6

    Investigations lack conclusions and follow-up

    Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, particulate matter on 5/20/2025 in approximately [illegible] syringes which were a part of your media fill lot [illegible]. These syringes were previously inspected by your [illegible] on 5/07/2025 and 5/15/2025 and were not identified with particulate matter. B. You documented INC-24-024 on 11/5/2024 for surface regarding ISO 5 hood [illegible] as observed with "overgrowth" of Rhizopus-oryzae. Lot [illegible] of Phenylephrine was rejected. Your root cause was inconclusive, and you did not document additional CAPA actions to address this failure.

  7. 7

    Stability testing and expiry determination lacking

    An adequate number of batches of each drug product are not tested to determine an appropriate expiration date. Specifically, You discontinued your stability program in approximately 2018 per your site leadership personnel. You have continued to produce various drug products to include but not limited to Fentanyl [illegible], lot [illegible] in bags, Succinylcholine [illegible], lot [illegible] m syringes. Succinylcholine is produced in lots of [illegible].

  8. 8

    In-process control procedures inadequate

    Written procedures are not established, written and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch. Specifically, A. You lack establishment of scientifically justifiable in-process limits regarding visual inspection. Your limit is Vo, in aggregate for your 100% inspection in addition to your post 100% inspection sample(s). You have not established limits specific to individual defect categories to include but not limited to leakers and particulate matter. You have detected units with fibers and leaking units during your 100% inspection. B. You lack use of adequate equipment [(b)(4)] regarding visual inspection. You currently utilize 11 backgrounds without adequate lighting. C. You do not comprehensively document your post 100% inspection sample to support the sample is appropriate numerically and that it represents the entire batch.

  9. 9

    Inadequate employee training and qualifications

    Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. A. Your visual inspection qualification training is inadequate regarding both your initial qualification and your lack of requalification. 1. You lack an annual requalification process. 2. Your initial qualification is not scientifically established nor standardized. Your initial visual inspection qualification is conducted via On-the-Job Training only. While you have a defect kit, it is not used to qualify your operators. 3. Your initial qualification process lacks assurance that operators are trained to observe and detect critical, major, and minor defects.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3009925820, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.