Medi-Fare Drug and Home Health Center, Inc. Form 483, September 2014
FDA issued this Form 483 to Medi-Fare Drug and Home Health Center, Inc. in Blacksburg, South Carolina (FEI 3009925820) at the end of a drug inspection that ended September 12, 2014. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 12, 2014
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 17, 2024
- 3,414 days after the inspection
The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic cleaning/disinfection system
1) Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) The firm currently utilizes (b)(4) to disinfect inside the ISO 5 Laminar Air Flow Work Benches (aseptic processing areas); nonetheless, these disinfecting agents are not sterile. b) Disinfecting and sporicidal agents, including dilution, being utilized for aseptic processing areas have not been selected based on a formal assessment as established in the written and approved standard operating procedure 4.010: Cleaning Program, effective 10/01/13. In addition, contact times need to be established.
- 2
Missing required outsourcing facility labeling
2) The labeling of your outsourcing facility's drug products do not include information required by section 503B(a)(10). Specifically, (a) The drug product labels do not include the date that the drug was compounded (503B(a)(10)(A)). (b) The drug product containers do not include information to facilitate adverse event reporting and directions for use (503B(a)(10)(B)).
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3009925820, newest first.
- Form 483, June 2025Inspection ended Jun 6, 2025 · Posted Aug 7, 2025OAI
- Form 483, May 2023Inspection ended May 26, 2023 · Posted Mar 21, 2024VAI
- Form 483, June 2013Inspection ended Jun 21, 2013 · Posted Jan 17, 2024VAI
- Form 483, July 2015FDA record date Jul 10, 2015 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.