Medi-Fare Drug Pharmaceutical Compounding LLC
300 W Pine St, Blacksburg, South Carolina, United States
FEI 3009925820DUNS 091326520
FDA has 6 inspections on file for Medi-Fare Drug Pharmaceutical Compounding LLC in Blacksburg, South Carolina (FEI 3009925820), from 2013 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for relabeling and repacking, through Dec 31, 2026. Its registrant is Medi-Fare Drug (D-U-N-S 091326520).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2013–2025
- 2 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 6
- 3 posted 483s not matched to an inspection
- Requested under FOIA
- 1 request, latest Jul 29, 2025
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterility contamination prevention lacking
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. I visually observed contaminated / stained HEPA filter affecting ISO 5 hood in addition to hood [illegible] hoods, also have apparent contamination / stains. To date, no investigation has been opened regarding this apparent contamination. B. You lack a scientifically established qualification process regarding your media fill unit inspections. You have not demonstrated, via training and qualification, that personnel can accurately and repeatedly detect failing units. C. You rejected lot of repacked Proparacaine HCl 0.5% due to sterile caps coming off of your (b)(4) syringes during production. You documented this via INC-24-014 which records the use of caps lot [illegible]. These caps had not been scientifically evaluated prior to use to include actions including but not limited to change control, process validation and / or media fills. After this batch rejection, you documented CAPA-24-005 which includes the use of a new vendor cap. While CAPA-24-005 requires container closure integrity testing of approximately [illegible] units, it does not require such actions as process validation, stability testing and / or media fills.
- Observation 2
Cleaning and disinfection system deficient
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, A. I observed apparent white colored residue and apparent brown or red colored stains on your work surfaces in your ISO 5 hood. The apparent white colored residue is also apparent throughout your ISO 5 environment affecting approximately all hoods. The design with the approximate of your working surfaces offers hard to clean surfaces. To date, [illegible] investigation has been opened regarding this apparent contamination. B. You have failed to confirm and maintain the cleanliness of your ISO 5 environments. 1. You use [illegible] to generate smoke during your airflow pattern evaluations. You have not performed testing to support the adequacy of your cleaning procedures for the presence or absence of [illegible] after you have cleaned and sanitized your ISO 5 environments. 2. I observed cleaning and sanitizing activities using [illegible] on 5/19/2025 which included ISO 5 hood. I observed your ISO 5 surfaces began to [illegible] no later than (b)(4) and become fully dry at approximately (b)(4) post cleaning and sanitizing activities. Your written procedures require you to maintain contact times of (b)(4) for [illegible].
Show observations 3 to 9
- Observation 3
Facility flow and pressure controls deficient
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. The design of your facility allows for operations to include material flows directly between unclassified areas and your ISO 7 sterile compounding room, "Room [illegible]". Specifically, materials flow from your non-classified "Prep Room" to your ISO 7 compounding room, "Room [illegible]" and from "Room [illegible]" to your non-classified room, "Quarantine Area". Non-classified areas lack continuous monitoring of differential pressures as well as non-viable particles. B. Air pressure differential limit setpoint alarms and alarm delays are not scientifically established nor monitored regarding your ISO 7 room where you produce sterile drug product(s). You did not establish real-time setpoint limit alarms according to your written SOPs such that your SOP requires differential pressures of [illegible] W.C. Your actual alarm limits are [illegible] W.C. Furthermore, you established alarm delays of approximately [illegible] per your electronic monitoring system and / or vendor as well as your Quality Director. Your written SOPs lack reference to any air differential alarm delays.
- Observation 4
Environmental monitoring system inadequate
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Personnel and environmental monitoring during and after your aseptic connection as well as throughout aseptic production is not scientifically performed. 1. The system by which you conduct personnel monitoring is not scientifically established. I observed personnel enter your ISO 5 environment with their hands and arms. You do not currently routinely perform personnel monitoring regarding production personnel forearms. 2. I observed aseptic operators perform finger-tip personnel monitoring after performance of the aseptic connection unit step which includes bulk filling. However, multiple glove changes occurred during this process. B. Non-Viable Particle (NVP) monitoring is conducted in the ISO 5 hoods. This NVP monitoring is not continuously performed. Furthermore, the firm produces sterile drug products in multiple ISO 5 hoods concurrently and only owns one NVP monitoring device.
- Observation 5
Supplier reports accepted without validation
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, you have not certified that water is sterile and nonpyrogenic whereby it is accompanied by a valid COA to ensure the reliability of the supplier's Certificate of Analysis. Water is used in the production of sterile drug products to include Fentanyl [illegible] 10 mcg/mL in [illegible] bags.
- Observation 6
Investigations lack conclusions and follow-up
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, particulate matter on 5/20/2025 in approximately [illegible] syringes which were a part of your media fill lot [illegible]. These syringes were previously inspected by your [illegible] on 5/07/2025 and 5/15/2025 and were not identified with particulate matter. B. You documented INC-24-024 on 11/5/2024 for surface regarding ISO 5 hood [illegible] as observed with "overgrowth" of Rhizopus-oryzae. Lot [illegible] of Phenylephrine was rejected. Your root cause was inconclusive, and you did not document additional CAPA actions to address this failure.
- Observation 7
Stability testing and expiry determination lacking
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date. Specifically, You discontinued your stability program in approximately 2018 per your site leadership personnel. You have continued to produce various drug products to include but not limited to Fentanyl [illegible], lot [illegible] in bags, Succinylcholine [illegible], lot [illegible] m syringes. Succinylcholine is produced in lots of [illegible].
- Observation 8
In-process control procedures inadequate
Written procedures are not established, written and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch. Specifically, A. You lack establishment of scientifically justifiable in-process limits regarding visual inspection. Your limit is Vo, in aggregate for your 100% inspection in addition to your post 100% inspection sample(s). You have not established limits specific to individual defect categories to include but not limited to leakers and particulate matter. You have detected units with fibers and leaking units during your 100% inspection. B. You lack use of adequate equipment [(b)(4)] regarding visual inspection. You currently utilize 11 backgrounds without adequate lighting. C. You do not comprehensively document your post 100% inspection sample to support the sample is appropriate numerically and that it represents the entire batch.
- Observation 9
Inadequate employee training and qualifications
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. A. Your visual inspection qualification training is inadequate regarding both your initial qualification and your lack of requalification. 1. You lack an annual requalification process. 2. Your initial qualification is not scientifically established nor standardized. Your initial visual inspection qualification is conducted via On-the-Job Training only. While you have a defect kit, it is not used to qualify your operators. 3. Your initial qualification process lacks assurance that operators are trained to observe and detect critical, major, and minor defects.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Representative samples after completion
Samples of representative units were not visually examined for correct labeling at the completion of finishing operations.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic cleaning/disinfection system
1) Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) The firm currently utilizes (b)(4) to disinfect inside the ISO 5 Laminar Air Flow Work Benches (aseptic processing areas); nonetheless, these disinfecting agents are not sterile. b) Disinfecting and sporicidal agents, including dilution, being utilized for aseptic processing areas have not been selected based on a formal assessment as established in the written and approved standard operating procedure 4.010: Cleaning Program, effective 10/01/13. In addition, contact times need to be established.
- Observation 2
Missing required outsourcing facility labeling
2) The labeling of your outsourcing facility's drug products do not include information required by section 503B(a)(10). Specifically, (a) The drug product labels do not include the date that the drug was compounded (503B(a)(10)(A)). (b) The drug product containers do not include information to facilitate adverse event reporting and directions for use (503B(a)(10)(B)).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing, packing, and holding of drug products is not appropriate for the duties they perform.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 29, 2025. It asked for a Form 483.
Inspection ending Jun 6, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 29, 2025FDA-FOIA-2025-9183Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.134Drug product inspection1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Medi-Fare DrugD-U-N-S 091326520
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009925820 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009925820. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.