Wizcure Pharmaa Private Limited Form 483, December 2025
FDA issued this Form 483 to Wizcure Pharmaa Private Limited in Alwar, India (FEI 3030304532) at the end of a drug inspection that ended December 10, 2025. It lists 7 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on June 24, 2026.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 27, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Dec 10, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jul 27, 2026
- 229 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Incomplete laboratory records and data integrity failures
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards Specifically, Microbiologists responsible for performing sterility testing and collecting environmental monitoring, personnel monitoring, and (b)(4) samples confirmed they do not collect, test, and incubate all samples. A. During inspection of the (b)(4) Biological incubators in the microbiology laboratory on December 5, 2025, (b)(4) personnel monitoring plates were observed and photographed with visible microbial growth. On December 6, 2025, (b)(4) of the (b)(4) plates previously observed with growth were observed with no growth. Upon examination, the plates on December 6, 2025 were missing the initials of the microbiologist who plated them, and the plates appeared to be different although the labeling information was the same (except for the missing microbiologist initials). The remaining (b)(4) plates were missing. When questioned about this discrepancy, Microbiologist (b)(6) stated that he had labeled unused plates with the same information and discarded the plates with growth. B. Upon inspection of the (b)(4) Biological incubators in the microbiology laboratory on December 3, 2025, sterility testing, personnel monitoring, environmental monitoring, and (b)(4) samples that were supposed to have been collected and under incubation were not present. Associated logbooks and analytical worksheets containing testing data were also incomplete or missing. Examples included: 1. There were samples in the incubators for approximately (b)(4) lots of products in varying stages of in-process sterility testing but no in-process test records. According to Microbiology Manager (b)(6), sterility (b)(4) are examined (b)(4). Results of these examinations are not recorded (b)(4) but (b)(4) record is created. In addition, Microbiology Manager (b)(6) explained that positive and negative controls for sterility testing methods have not been routinely conducted since October 2025 and there has not been any growth promotion testing done on the (b)(4) used for sterility testing for over a year. 2. There were no personnel monitoring samples in the incubators. Procedure MBP023 "Procedure for Personnel Monitoring by Contact Plate Method" requires personnel monitoring for all personnel (b)(4). A microbiologist confirmed none of the samples were collected. 3. Environmental monitoring settle plates are not collected according to Procedure MB021 "Procedure for Environmental Monitoring by Settle Plate Method". On December 3, 2025, only (b)(4) settle plates from (b)(4) were found in the bacteriological incubator, representing the following locations: (b)(4). Based on procedural requirements, a minimum of (b)(4) from Grade A locations and (b)(4) plates should be collected ((b)(4)) approximately (b)(4) plates from Grade B locations. For the (b)(4) total plates should have been collected (b)(4). 4. During inspection of environmental monitoring records and media preparation documentation from (b)(4), a systematic review was conducted to assess the adequacy of media preparation relative to environmental monitoring (EM) and media fill testing performed. This analysis revealed discrepancies between documented media volume and recorded usage / testing results. i. Media Preparation vs Environmental Monitoring Results: (b)(4) plates prepared: (per Media Preparation Records) Environmental monitoring results recorded: (b)(4) results Discrepancy: results recorded without corresponding media preparation (b)(4) plates prepared: (b)(4) (per Media Preparation Records) Environmental monitoring results recorded: [illegible] results (b)(4) media (b)(4) prepared: (per Media Preparation Records) for controls (b)(4) Sterility Logbook: (b)(4) samples received (plus (b)(4) needed to conduct testing sterility testing is initiated) = (b)(4). Microbiology Manager (b)(6) confirmed that media is made (b)(4). A comprehen
Shortened here; the PDF has the full text.
- 2
Rusty and uncleanable production equipment
Equipment and utensils are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. The following were observed throughout productions areas used to manufacture products for the US market. A. The (b)(4) Line consisting of rooms (b)(4) used to manufacture (b)(4) for the US market: 1. Apparent rusty equipment, apparent rusty components (b)(4), apparent rusty machine parts on and around filling zone such as the (b)(4) parts and (b)(4) tracks (b)(4). 2. Stained / apparent rusty HEPA filters and / or HEPA filter (b)(4) as well as (b)(4). 3. (b)(4) with apparent rust is used to transport the (b)(4) product transfer vessel (b)(4) from (b)(4) room to filling room. B. The (b)(4) Line consisting of rooms (b)(4) used to manufacture (b)(4) (b)(4): 1. Apparent rusty equipment on the (b)(4) machine (Eq. ID - WPPL/BH/PD/EQP/100) including: i. (b)(4) used to (b)(4) ii. (b)(4) directly above location where finished product (b)(4) iii. Apparent rusty (b)(4) directly over (b)(4). 2. (b)(4) on the machine (Eq. ID - WPPL/BH/PD/EQP/100) is not easily cleanable and is replaced (b)(4). The assessment and replacement of the (b)(4) is not documented. (b)(4) was observed in the following location i. The entire (b)(4) where finished product (b)(4) used to ii. Under a (b)(4) (b)(4) iii. Beside the (b)(4) where (b)(4). Additionally, this (b)(4) appears to be secured with tape. 3. Apparent rusty equipment on the (b)(4) Filling & Sealing Machine (Eq. ID - WPPL/BH/PD/WQP/101) in the following locations: i. directly over the packaging (b)(4) (b)(4). This is immediately upstream of where the (b)(4) the finished product (b)(4) ii. (b)(4) for (b)(4) which (b)(4).
- 3
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Your firm aseptically fills OTC finished drug products (b)(4) for the US market. Your aseptic filling process includes: A. After sterilization of your (b)(4) product transfer vessel via (b)(4) performed in Washing and Sterilization Area (b)(4) you move this vessel into your Grade A space located in (b)(4) Filling Room (b)(4). Your (b)(4) product transfer vessel is moved via your (b)(4) into (b)(4) Filling Room (b)(4). Your Washing and Sterilization Area (b)(4) is a Grade B area, your corridor is a Grade B area and your (b)(4) is a Grade B Filling Room (b)(4) space with exception to your Grade A filling area located under your LAF. Your aseptic connection located on your (b)(4) product transfer vessel is not covered or protected during this transfer. B. Your firm performs aseptic filling on (b)(4) Filling Line (Room (b)(4)). On December 5th we observed setup on this line. This filling line has no barrier protection separating the filling line, to include the filling zone that harbors the (b)(4) are [illegible], area where (b)(4) loaded, area the (b)(4) resides and the area whereby open sterile bottles pass, by design, between Grade A and Grade B spaces prior to being filled. C. Contact surfaces of the sterile (b)(4) components are not sterilized. For example: 1. The (b)(4) bowl and (b)(4) track all contact sterile (b)(4) Filling Line (Room (b)(4)) (b)(4) packaging components. These pieces of equipment are left in place between batches and disinfected but not sterilized. 2. (b)(4) tubing connecting (b)(4) to the (b)(4) were not removed and are left in place between batches and disinfected but not sterilized. D. Media fills are not designed to ensure they provide a representative challenge to the aseptic filling process. The protocols do not: 1. Establish and record the number of interventions that must occur 2. Establish the limit for the number of personnel that may be present in the room during aseptic processing 3. Establish the time(s) and attribution of personnel regarding aseptic connections E. Comprehensive static and dynamic airflow pattern studies were not conducted for the (b)(4) Filling Line Rooms (b)(4). 1. Static airflow studies were limited to areas immediately surrounding entry and exit doors and HEPA (b)(4) (within (b)(4) of these locations only). 2. No dynamic smoke studies were performed to evaluate critical operational scenarios, including line set-up activities, aseptic connections and interventions during operations 3. The studies did not include evaluation of Grade A spaces, which are critical areas requiring the highest level of air quality control. F. Line design with (b)(4) bottles from Grade A where they are (b)(4) loaded through Grade B then back to Grade A where they enter the track to move to the filling station. G. You use (b)(4) to clean and sanitize equipment used in your aseptic (b)(4) filling room prior to filling. You lack documentation supporting the (b)(4) is sterilized. Furthermore, the bulk drum observed in your basement and usage records / logs are also absent.
- 4
Poor aseptic behavior during filling setup
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. A. On December 5th, 2025, while observing set-up on (b)(4) Filling Line (Room (b)(4)) for the aseptically filled finished drug product (b)(4) batch (b)(4) poor aseptic processing behavior was observed. This filling line is used to manufacture US market product. Examples of poor aseptic behavior include: 1. An operator exited the filling room and returned with (b)(4) for the (b)(4) filling apparatus, these ((b)(4) in total) are affixed to this filling apparatus in close proximity to aseptic connections, approximately (b)(4). 2. Operators were specifically observed moving freely between Grade A and Grade B spaces without any record of their movements and activities throughout the entire setup process. 3. Operators were observed with exposed skin while performing maintenance activities on the (b)(4) assemblies in close proximity to the filling station and / or while performing aseptic connection. 4. Operators were observed wearing safety glasses with exposed skin around the glasses. In addition, operators were observed moving their protective eyewear (glasses) such that they rested on their forehead while their head was inside the Grade A area. 5. Operators were observed reaching into the open bag containing sterile bottles multiple times to remove bottles from the bag and place them on the (b)(4). This technique was used to place all bottles on the (b)(4). 6. During the aseptic connection between the sterile transfer manufacturing tank (b)(4) and the manifold for the filling line, an operator was observed touching the opening of the tubing and tubing connections on the manifold and (b)(4) apparatus prior to making the connection, touching the approximate gasket used to aseptically connect the transfer tank and manifold. 7. Direct contact with HEPA filters by operators' heads was observed. 8. Two power failures occurred during setup operations at approximately 11:40am and 12:40pm which were not documented. Upon resumption of power, operations continued without removal of potentially compromised materials and cleaning was not performed. 9. During (b)(4) interventions for filling the (b)(4) bowl, operators were observed with their gowning directly over and in contact with the interior surfaces of the bowls. Additionally, operators touched the grasping ends of forceps (the portions that directly contact (b)(4)) and then used the same contaminated forceps to [illegible] on the (b)(4) track and operators were observed adjust (b)(4) touching the (b)(4) track with their gloved hand directly. These practices create multiple contamination pathways that could compromise the sterility of product-contact components. 10. Operator gowning appeared with tears / holes and markings / writing on it such as dates / places where zippers are coming away from the fabric 11. An operator was observed unzipping his protective equipment to remove and use his mobile phone. B. On December 8th, 2025, while observing set-up, filling, and transfer of equipment and components on (b)(4) Filling Line (Room (b)(4)), for the aseptically filled finished drug product (b)(4) batch (b)(4) Lot (b)(4) poor aseptic processing behavior was observed. This filling line is used to manufacture US market product. Examples of the observed poor aseptic behavior include: 1. The (b)(4) bag with the manifold and attached tubing was observed unsealed and open to the outside environment. Operator (b)(6) stated the [illegible] manifold is (b)(4) "as is". 2. From 10:43-10:50 AM, Aseptic Connections from manifold to (b)(4) and manifold to sterile manufacturing transfer tank. During these connections, we observed multiple instances of the operator touching the (b)(4) assemblies on the (b)(4) assembly and touching the (b)(4) used to connect the (b)(4) tubing to the (b)(4) gasket used during the connection of the manifold tubing to the sterile man
Shortened here; the PDF has the full text.
- 5
Deficient environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Personnel monitoring program has not been implemented for any aseptic operations. Personnel monitoring regarding aseptic connections has never been conducted. B. Surface monitoring has never been performed on any equipment surfaces including critical product contact surfaces such as (b)(4) product contact locations including (b)(4). C. Active viable air sampling has never been implemented in any aseptic processing areas. D. Passive air monitoring is only performed regarding (b)(4) during aseptic processing in your Grade A space and the location is not clearly defined in your quality system. E. Non-viable particle monitoring was not performed during setup operations observed on December 5, 2025. Furthermore, your QA Manager reported you do not perform NVP measurements during any filling operations and only perform NVP monitoring prior to setup and filling operations.
- 6
Missing production and process control procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. A. You do not perform visual inspection of your aseptically filled product, and you have not established written procedures regarding this critical process. Your QA Manager reported you inspect the outside of each unit for defects to include particles but do not inspect the contents. B. You lack control over critical elements of your terminally sterilized (b)(4) process for the following: [illegible]. C. You lack recordation of critical process parameter(s) in your BPRs regarding your (b)(4) process such that (b)(4) is not recorded. Your production personnel reported (b)(4) was required for (b)(4). 1. Enumeration of rejects is absent regarding your in-process visual inspection of filled (b)(4) for your (b)(4). Furthermore, critical attribute of (b)(4) integrity is apparently incorporated into your process, instead, your BPRs read in part, "OK". "other" rejects category. I observed at least one reject regarding (b)(4) during inspection of approximately (b)(4) units.
- 7
Quality unit procedures not followed
The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. A. You do not document quality system events such as deviation, OOSs and changes. 1. No deviations or OOS were generated for the EM/PM deficiencies nor for any discarded QC records identified during the inspection. 2. per Microbiology (b)(4) testing forms changes were made approximately (b)(4) (b)(6) samples. No Manager, subsequently causing you not to collect over (b)(4) Change control nor other quality record was opened to capture this event. 3. You performed a change to your method validation for your (b)(4) and did not document this revalidation via any change control. B. At the initiation of this inspection on December 3, 2025, we found GMP documents that were disposed inside a bag which was inside a box collected from QC Documentation Room (b)(4). The evaluation of the contents of the bag revealed presence of (b)(4) Analysis sheets from (b)(4) validation data summary sheets, (b)(4) from 2019, certified copy of the validation certificate for the Bacteriological Incubator from 2022. Other items in the bag included vials of (b)(4) Injection USP, unlabeled (b)(4) (b)(4) containing a (b)(4) liquid, unlabeled vials containing a (b)(4) liquid, among other scraps of paper. 1. Logbooks (b)(4) (Testing Log Book and Bulk Sample Testing Log Book) for year 2025 were observed with missing sample received entries. 2. Log Book for gross QC calculations was observed and your QA Manager stated it was not a GMP logbook and reported the logbook is not controlled via any written SOP per your quality system.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJun 24, 2026Wizcure Pharmaa Private Limited warning letter, June 24, 2026CDER · 196 days after this inspection ended
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.