Skip to content

Shouguang Fukang Pharmaceutical Co., Ltd. Form 483, February 2025

FDA issued this Form 483 to Shouguang Fukang Pharmaceutical Co., Ltd. in Weifang, China (FEI 3003941038) at the end of a drug inspection that ended February 21, 2025. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted May 6, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 21, 2025
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
May 6, 2026
439 days after the inspection
Facility
FEI 3003941038
Weifang, China

The 9 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    QC lacks final test approval

    The quality control unit lacks responsibility to approve final testing results for product release. Specifically, a review of completed analytical testing records for the API [illegible] regarding HPLC L-002 and GC L-0[illegible] testing results noted that QC performs the review/approval without review/approval by the QA department. For example, the chemist uses Excel Spreadsheets to manual input testing result data from both the HPLC and GC. The spreadsheets are used to calculate final testing results for Related Compounds, Impurity and Residual Solvents. Once the data has been entered and values obtained, the chemist prints a hardcopy of the spreadsheet and then resets the Excel Spreadsheet back to the original status. The original data is not saved and QA is not able to review this data for final approval for the batch. In addition, a review of the final testing records for this batch noted that the HPLC and GC chromatographs are not included in the final release packet for QA review.

  2. 2

    Equipment cleaning and maintenance inadequate

    Equipment is not cleaned or maintained at appropriate intervals to prevent contamination that would alter the quality or purity of the API product. A) Specifically, on 2/18/2025, inspection of the Workshop [illegible] where the API (b)(4) is manufactured noted excess residual product remaining on the bottom, upper wall, and shaft for the [illegible] Machine-[illegible] and [illegible] Machine-[illegible]. These units are used for [illegible] processing step. The previous API batches processed in Unit# [illegible] was Batch [illegible] and Unit# [illegible] was Batch [illegible]. Per management, in-between batches only external cleaning of these units are performed and internal cleaning is only performed on a [illegible]. Also, Unit# 003 was observed to have corroded bolts and other corroded parts located on the [illegible] shaft of this unit. Per record review, the last internal cleaning of Unit [illegible] and Unit [illegible] was 2/3/2025. Also, a review of the last maintenance record for Unit [illegible] dated [illegible] noted no issues regarding corroded parts. The excess residual product carryovers and corroded parts create contamination issues. B) Specifically, on 2/18/2025, inspection of the workshop, where the API is manufactured noted extensive damage to the bottom of the vessel [illegible] which was being used to process [illegible] (Batch # [illegible]). [illegible] was observed to be dripping onto the floor from the bottom of this vessel. Management stated that this [illegible] was from the [illegible] that was being generated during this processing step in this vessel. The last preventive maintenance was performed on 9/22/2024 and no issues were noted regarding the current condition of the damaged bottom of this vessel. C) Specifically, on 2/17/2025, inspection of the firm's [illegible] water system located in Building [illegible] that supplies [illegible] water to Workshop # [illegible] where the API [illegible] is manufactured noted that the distribution [illegible] that supplies [illegible] water to this workshop was observed to be leaking. [illegible] water in Workshop [illegible] is used to clean processing equipment. D) SOP-CH-E09 "Procedure for Usage Maintenance and Servicing of [illegible]" identifies a [illegible] check of the level for the [illegible]. Operators are required to record this check in the equipment log book. However, during my review of the equipment log books for the [illegible] (Equipment ID observed [illegible]) the operators are not performing or recording this activity as required by SOP-CH-E09. This equipment is located in Workshop # [illegible] and used in the manufacturing of the API (b)(4) for the U.S. market.

  3. 3

    Storage areas allow cross-contamination

    Separate or defined areas to prevent contamination are deficient regarding operations related to the storage of raw materials and finished API products. A) Specifically, on 2/17/2025, inspection of the firm's raw material warehouse [illegible] noted raw materials stored in unsanitary conditions and not properly identified; for example, poor lighting conditions, raw materials were not identified or labeled, raw materials stored against walls, leaking [illegible], residues on concrete floor, and exterior door with large gaps for possible rodent/insect entry. B) Specifically, on 2/17/2025, inspection of the firm's finished API non-dedicated storage warehouse [illegible] noted the API [illegible] was being stored in random locations throughout this warehouse. This API is a [illegible] and cross-contamination issues can occur with this product being randomly stored with [illegible] products such as [illegible] for the U.S. market. Per the firm's Site Master File, preventative measures will be taken to prevent cross-contamination.

  4. 4

    Critical control steps not identified

    The firm has failed to identify all critical control steps in the manufacturing process. Specifically, your firm identified an out of trend (OOT) for the related substances analytical results for (b)(4). According to the investigation, the related substances results were [illegible]; identified a (b)(4) OOT limit is (b)(4), and the release specification is [illegible]. The root cause for the OOT identified that the product remained in the [illegible] for approximately (b)(4). To this date, your firm has not performed a risk assessment to identify the impact that this manufacturing step may have on the API and the controlling of impurities. Additionally, your firm has not identified the hold time in the [illegible] as a critical step in the batch records, process validation, or any related SOPs.

  5. 5

    Analytical method validation incomplete

    Analytical methods are not suitable for their intended use and/or have not been established. Specifically, A. The validation report, "Validation Report of Analytical Procedure for Related Substances in (b)(1) (USP/EP)," does not reference the batch numbers associated with the validation. There is no assurance that any (b)(1) batches were associated with this method validation. B. The validation report, "Validation Report of Analytical Procedure for HPLC Method for Impurity [illegible] (b)(1) (USP/EP)," does not reference the batch numbers associated with the validation. There is no assurance that any [illegible] batches were associated with this method validation.

  6. 6

    Sample chain-of-custody not documented

    Samples taken of products for determination of conformance to written specifications are not properly released to the QC department of testing. Specifically, on 2/19/2025, during the inspection of the firm's sample receiving department, concerns were noted regarding the chain of custody of samples to ensure accountability of sample materials and sample integrity issues. For example, samples for [illegible] Batch [illegible] with Sample ID as [illegible] and [illegible] were taken by the QC department to perform required testing on 2/19/2025. The initial weights for these samples were [illegible] and [illegible], respectively. The date and amount returned by the QC department to the sample department for storage is not documented. During this inspection, these samples were re-weighted and the weights were [illegible] and [illegible], respectively.

  7. 7

    Hold time studies not established

    Time limits are not established for the completion of each production phase to assure the quality of the drug product. A) Specifically, hold time studies regarding the time between each different processing step for the production of the API (b)(4) have not been established or validated for Workshop [illegible] located in Building [illegible]. B) Specifically, Dirty and Clean hold time studies for processing equipment located in the non-classified air quality areas in Workshop [illegible] in Building [illegible] where the API [illegible] is processed have not been established or validated.

  8. 8

    Improper aseptic technique in microbial testing

    Failure to perform proper aseptic techniques during microbial testing of products. Specifically, on 2/19/2025, Technicians in the firm's QC microbial department were observed not performing proper aseptic techniques for the inoculation of media plates for (b)(4) tablet microbial testing. For example, one technician was observed on numerous occasions placing gloved hands outside into the Class C area and then inside the Class A hood without sanitizing gloved hands upon reentry to the hood. Another technician working under the same hood was observed on numerous occasions retrieving sample bottles located on [illegible] in the Class C area outside of the hood and then placing these sample bottles inside the Class A hood without sanitizing the exterior of the sample bottles or gloved hands prior to reentry into the hood. Also, it should be noted that no sanitizing agent was available for these technicians to use in this area and no microbial settling plates were used in the Class A hood while performing microbial testing. Microbial testing is performed on environmental monitoring [illegible] and [illegible] water used for the production/cleaning of the APIs, and [illegible] for the U.S. market.

  9. 9

    Insufficient lighting in warehouse areas

    Adequate lighting is not provided in all areas. Specifically, on 2/17/2025, inspection of the firm's raw material warehouse (b)(1) where raw materials for the API (b)(1) and (b)(1) are stored noted dim lighting conditions in this warehouse. These conditions hinder the proper monitoring of raw materials stored in this warehouse such as for temperature/humidity monitoring and identification of stored raw materials.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.