Hikma Injectables USA Inc.

New Jersey

FEI 3022897129

FDA has 2 inspections on file for Hikma Injectables USA Inc. in New Jersey (FEI 3022897129), from 2022 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
2, 2022–2025
0 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Jun 24, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate visual inspection criteria

      Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm's procedure, Standard Operating Procedure SOPDTN15125, "100% Visual Inspection of Compounded Sterile Products," Revision 3.0, effective December 30, 2024, establishes [illegible]% reject rate threshold before initiating quality events for 100% visual inspection processes (Section 7.10.12): 1. A [illegible]% rejection threshold allows nearly [illegible]% of manufactured units to be defective before triggering investigation. Your firm's procedures provide no rationale or scientific justification for the [illegible]% reject rate threshold. The SOP fails to specify whether this threshold applies to total rejects (combination of Critical, Major, and Minor defects) or to individual defect classifications. 2. Standard Operating Procedure SOPDTN15125, "100% Visual Inspection of Compounded Sterile Products," Revision 3.0, effective December 30, 2024 indicates that if the [illegible]% reject rate is exceeded, a quality event will be initiated. For batches that fail the first AQL inspection and that have not already been labeled, a 100% re-inspection of the entire batch is allowed. Your procedures also permit conducting a 100% visual inspection and AQL without investigating the root cause of the initial AQL failure. 3. Ketamine HCL batch# 250860010D was produced on 04/02/2025. Visual inspection of the batch revealed a 24.4% rejection rate in which units were overfilled (a critical defect). The firm's AQL inspection passed with no defects noted. The firm's investigation (ERF-2025-065) detailed that the root cause was attributed to personnel. A classroom training was conducted for SOPDTN15120 (Final Container Fill Task of the Compounding Process). Per the investigation, the overfilled syringes were discarded, and units were released by Quality on 05/02/2025.

    2. Observation 2

      Equipment cleaning and sanitation

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, On 07/29/2025, black discoloration was observed on the interior HEPA bracket of the Aseptic Processing Workstation. This was located within Room 121-B and was being utilized in the sterility testing of the following: Ketamine HCL lot# 252050004D, Diltiazem HCL lot# 251910016D and Rocuronium Bromide lot# 252050002D.

    Show observations 3 to 4
    1. Observation 3

      Incomplete environmental air monitoring

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, The firm's procedure for collecting active viable air within the ISO-5 laminar airflow hood is not representative of the full duration of the sterile production process. The firm will only collect [illegible] of air within approximately [illegible] and that the production process within the laminar airflow hood lasts approximately [illegible]. For example, the aseptic process for Ketamine HCL 50 mg per 5 mL Lot# 25150009D was initiated at [illegible] on 06/10/2025. The aseptic process concluded at [illegible] and the active viable air sample was only collected at 9:22 am.

    2. Observation 4

      Deficient sterility testing procedure

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, The firm's procedure for testing (SOPDTN15300) is deficient in that [illegible] can be [illegible] and evaluated via [illegible] test for a total of [illegible] times before an investigation is conducted. For example, Event Report Form (ERF) #2025-067 was initiated on 04/16/2025 to document testing of Rocuronium Bromide 50 mg/5 mL (lot# 250780001D). Per the investigation, [illegible] with [illegible] and analyzed via the [illegible] test. The test failed and a [illegible] was conducted, and a [illegible] performed. The test failed and [illegible] conducted, and a test was performed. The test was conducted, and a test was performed. The test failed and a [illegible] was conducted, [illegible] test was performed. The test failed, and an investigation was initiated. The investigation revealed that a leak in the tubing that connected to the Testing Instrument was the root cause of the failed results. The [illegible] was then tested again after the repair, passing results were achieved and the batch was released and distributed.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    3. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jun 24, 2026.

  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Jun 24, 2026FDA-FOIA-2026-6077EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3022897129 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3022897129. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.