Skip to content

XeCare LLC

Ohio

FEI 3017865039

FDA has one inspection on file for XeCare LLC in Ohio (FEI 3017865039). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Aug 17, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Hazardous drug cross-contamination controls

      OBSERVATION 1 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, 1) Your firm routinely produces hazardous drug products on shared tablet press equipment without employing a deactivating agent as part of the cleaning process between batches, relying solely on (b) (4). From 6/3/2026 through 6/9/2026, your firm produced the following hazardous drug products sequentially on tablet press NP4-2405 with only (b) (4) cleaning performed between each product: a. Tadalafil 8.5mg + Enclomiphene citrate 12.5mg tablets lots DFJRIFLEQPRS and QHKTRRHEKQFE b. Tadalafil 8.5mg + Finasteride 1.2mg + Minoxidil 3mg + Biotin 2.5mg + Vit B12 1mg + Vit D3 0.05mg + L-Theanine 50mg Tablets lots IKTTDKQPCGUT and TIGISITHFHGD c. Naltrexone HCL 14mg + Topiramate 44mg Vitamin B12 1mg Tablets lots UFISFTCFFTPS and DLCQHEGLUTQE 2) Your firm routinely performs hazardous drug powder weighing and sifting operations in Room 104, your designated hazardous weighing room, under conditions that do not consistently meet the required negative air pressure specifications. Review of the Building Management System (BMS) data for Room 104 from 5/13/2026 through 6/10/2026 revealed approximately 56 pressure differential alarm events, with excursion durations ranging from 5 minutes to a continuous all-day alarm on 6/9/2026. During this period, your firm actively weighed, sifted, or mixed, approximately [illegible] batches while alarm limits were exceeded. Batches weighed and sifted during this period include but are not limited to: a. Naltrexone HCL 14mg + Topiramate 44mg + Vitamin B12 1mg Tablet lot JGSLGUJJEFSI b. Tadalafil 8.5mg + Enclomiphene Citrate 12.5mg Tablet lot DFJRIFLEQPRS c. Finasteride 1.2mg + Minoxidil 3mg + Vitamin B12 1mg + Biotin 2.5mg + Vitamin C 100mg + Resveratrol 20mg + Zinc Sulfate 30mg Tablet lot UQTESLQHDGIF Your firm also actively weighed one batch of drug product, Naltrexone HCL 14mg + Topiramate 44mg + Vitamin B12 1mg Tablet lot KQUGJSIERGIP, during this period when positive pressure, 0.001" - 0.002" WC, was exhibited by Room 104 and Room 103a which should be negative pressure rooms by design, specification range (b) (4)

    2. Observation 2

      Sterile transfers exposed to ISO-7 air

      OBSERVATION 2 Materials were exposed to lower than ISO 5 quality air. Specifically, On 5/16/2026, during production of Semaglutide 5mg/2mL Solution for Injection, lot CERKTLEQQQIJ, we observed, via video review, the following poor transfers of material into the ISO-5 hood resulting in the material being exposed to the ISO-7 environment. At approximately 7:17pm the filling technician passed two inner bags of sterile tweezers into the ISO-5 hood while exposing the inner bags to the ISO-7 environment. At approximately 7:24 PM, 7:48 PM, and 8:02 PM, vial trays were transferred into the ISO-5 hood with the inner bag opened within the ISO-7 environment. During each transfer, the exposed vial tray was introduced into the hood with an approximate one-foot gap between the tray and the hood opening, resulting in direct exposure of the vial tray to the ISO-7 environment.

    Show observation 3
    1. Observation 3

      Use of untested water in gummies

      OBSERVATION 3 Use of ingredients not intended for pharmaceutical use in non-sterile drug production. Specifically, Your firm makes Minoxidil 1.5mg + Biotin 2.5mg chewable gummy products using (b) (4) [illegible] water that has not been tested. This water is used in your firm's formulation of the gummy product. Untested [illegible] water was used in the production of Minoxidil 1.5mg + Biotin 2.5mg chewable gummy lot UGDFEUSIHFGJ.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 17, 2026. It asked for a Form 483.

  • Inspection ending Jun 17, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 17, 2026FDA-FOIA-2026-7921Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3017865039 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3017865039. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.