XeCare LLC Form 483, June 2026
FDA issued this Form 483 to XeCare LLC in Ohio (FEI 3017865039) at the end of an inspection that ended June 17, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 10, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 17, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Sep 10, 2026
- 85 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Hazardous drug cross-contamination controls
OBSERVATION 1 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, 1) Your firm routinely produces hazardous drug products on shared tablet press equipment without employing a deactivating agent as part of the cleaning process between batches, relying solely on (b) (4). From 6/3/2026 through 6/9/2026, your firm produced the following hazardous drug products sequentially on tablet press NP4-2405 with only (b) (4) cleaning performed between each product: a. Tadalafil 8.5mg + Enclomiphene citrate 12.5mg tablets lots DFJRIFLEQPRS and QHKTRRHEKQFE b. Tadalafil 8.5mg + Finasteride 1.2mg + Minoxidil 3mg + Biotin 2.5mg + Vit B12 1mg + Vit D3 0.05mg + L-Theanine 50mg Tablets lots IKTTDKQPCGUT and TIGISITHFHGD c. Naltrexone HCL 14mg + Topiramate 44mg Vitamin B12 1mg Tablets lots UFISFTCFFTPS and DLCQHEGLUTQE 2) Your firm routinely performs hazardous drug powder weighing and sifting operations in Room 104, your designated hazardous weighing room, under conditions that do not consistently meet the required negative air pressure specifications. Review of the Building Management System (BMS) data for Room 104 from 5/13/2026 through 6/10/2026 revealed approximately 56 pressure differential alarm events, with excursion durations ranging from 5 minutes to a continuous all-day alarm on 6/9/2026. During this period, your firm actively weighed, sifted, or mixed, approximately [illegible] batches while alarm limits were exceeded. Batches weighed and sifted during this period include but are not limited to: a. Naltrexone HCL 14mg + Topiramate 44mg + Vitamin B12 1mg Tablet lot JGSLGUJJEFSI b. Tadalafil 8.5mg + Enclomiphene Citrate 12.5mg Tablet lot DFJRIFLEQPRS c. Finasteride 1.2mg + Minoxidil 3mg + Vitamin B12 1mg + Biotin 2.5mg + Vitamin C 100mg + Resveratrol 20mg + Zinc Sulfate 30mg Tablet lot UQTESLQHDGIF Your firm also actively weighed one batch of drug product, Naltrexone HCL 14mg + Topiramate 44mg + Vitamin B12 1mg Tablet lot KQUGJSIERGIP, during this period when positive pressure, 0.001" - 0.002" WC, was exhibited by Room 104 and Room 103a which should be negative pressure rooms by design, specification range (b) (4)
- 2
Sterile transfers exposed to ISO-7 air
OBSERVATION 2 Materials were exposed to lower than ISO 5 quality air. Specifically, On 5/16/2026, during production of Semaglutide 5mg/2mL Solution for Injection, lot CERKTLEQQQIJ, we observed, via video review, the following poor transfers of material into the ISO-5 hood resulting in the material being exposed to the ISO-7 environment. At approximately 7:17pm the filling technician passed two inner bags of sterile tweezers into the ISO-5 hood while exposing the inner bags to the ISO-7 environment. At approximately 7:24 PM, 7:48 PM, and 8:02 PM, vial trays were transferred into the ISO-5 hood with the inner bag opened within the ISO-7 environment. During each transfer, the exposed vial tray was introduced into the hood with an approximate one-foot gap between the tray and the hood opening, resulting in direct exposure of the vial tray to the ISO-7 environment.
- 3
Use of untested water in gummies
OBSERVATION 3 Use of ingredients not intended for pharmaceutical use in non-sterile drug production. Specifically, Your firm makes Minoxidil 1.5mg + Biotin 2.5mg chewable gummy products using (b) (4) [illegible] water that has not been tested. This water is used in your firm's formulation of the gummy product. Untested [illegible] water was used in the production of Minoxidil 1.5mg + Biotin 2.5mg chewable gummy lot UGDFEUSIHFGJ.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.