OurPharma LLC Form 483, August 2026

FDA issued this Form 483 to OurPharma LLC in Arkansas (FEI 3014064135) at the end of an inspection that ended August 12, 2026. It lists 3 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Sep 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 12, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Sep 22, 2026
41 days after the inspection
Facility
FEI 3014064135
Arkansas

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Aseptic sterilization in ISO 8 without justification

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, • (b)(4) Sterilization Performed in an ISO 8 Classified Room Batch records collected during the inspection confirm that (b)(4) sterilization was performed in Compounding Room (b)(4) which is classified as ISO 8. Specifically: Batch production records for two lots of Fentanyl Citrate/Bupivacaine HCl combination products, Lot 1019-01-2608-01 (Fentanyl Citrate 2mcg[base]/mL + Bupivacaine HCl 0.125% in (b)(4) added to 100mL 0.9% NaCl Bag; Master Production Batch Record No. GMP-PDTMethods-0218, Revision 01, Effective Date: July 9, 2026) and Lot 1081-01-2608-01 (Fentanyl Citrate 2mcg[base]/mL + Bupivacaine HCl 0.1% in SWFI added to 100mL 0.9% NaCl Bag; Master Production Batch Record No. GMP-PDTMethods-0239, Revision 01, Effective Date: July 15, 2026) — document that (b)(4) of the bulk drug solution was performed in an ISO 8 "(b)(4) storage room" (Compounding Room (b)(4)). Specifically, in both records, Step 1.2 instructs operators to sanitize materials for transfer to this room ((b)(4) Storage room/Compounding Room (b)(4)), Step 1.5 identifies (b)(4) Storage room/Compounding Room (b)(4) as the designated area for these operations, Section 4 (b)(4) Step 4.1 documents that (b)(4) sterilization of the bulk drug solution was performed in this room, and Step 4.4 directs removal of the (b)(4) pool bag from (b)(4) Storage/Compounding Room (b)(4) for transfer to the cleanroom. • No Risk Assessment or Scientific Justification Provided You were unable to provide a risk assessment, quality risk management document, validation study, or any other documented scientific justification supporting the use of an ISO 8 classified environment for (b)(4) sterilization of sterile drug products. No documentation identified that: [ ] Assessed the contamination risks associated with performing these operations outside of an ISO 5 environment; [ ] Evaluated whether ISO 8 conditions are adequate to protect the sterility of the drug product solution during sterilizing (b)(4); or [ ] Demonstrated that the firm identified, evaluated, and mitigated the elevated microbial and particulate contamination risk posed by the ISO 8 environment for these operations.

  2. 2

    Annual product reviews inaccurate and unverified

    Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Specifically, Annual product review (APR) records for six drug product families — Fentanyl Citrate, Fentanyl Citrate + Bupivacaine HCl, Fentanyl Citrate + Ropivacaine HCl, Hydromorphone HCl, Morphine HCl, and Ropivacaine HCl, covering review period 2024–2025 — contain multiple numerical inconsistencies, cross-product data errors, and documentation inaccuracies. When presented with these findings during the inspection, firm management confirmed that the errors were mistakes and that corrected records had not been issued prior to the inspection. DATA INTEGRITY & STATISTICAL ERRORS APR Document Error Category Finding Detail Fentanyl Citrate + Bupivacaine HCl APR Irreconcilable Batch Disposition Percentages The firm reported three mutually inconsistent released percentages (97.65%, ~96.1%, and 96.5%) and could not identify which figure was correct. Fentanyl Citrate + Bupivacaine HCl APR Inconsistent Unit Denominator Across Reject Categories Table 1 uses an incorrect denominator of 93,573 units — rather than the correct (b)(4) units used for all other reject categories in the same table — to calculate the in-process reject rate, a (b)(4)-unit error the firm acknowledged. Fentanyl Citrate + Bupivacaine HCl APR FID (b)(4) Omitted from OOS and Disposition Trend Data FID (b)(4) was listed as a covered facility but absent from all data tables, creating a potential gap in the annual product review if production occurred. The firm confirmed the omission was accidental. Completeness of data evaluation for FID (b)(4) remains unresolved. Fentanyl Citrate + Ropivacaine HCl APR Mathematical Error in Visual Inspection Reject Table Table 2 understates the "Other Major" reject rate nearly 39-fold (0.05% reported vs. ~1.95% actual), an acknowledged calculation error uncorrected at the time of inspection. Hydromorphone HCl APR Lot Count Data Copied from a Different Product Family Table 4 of the Hydromorphone HCl APR uses Fentanyl Citrate lot counts (b)(4) instead of the correct Hydromorphone HCl total (b)(4); the firm confirmed the error but could not provide correct disposition data at the time of inspection. Hydromorphone HCl APR Irreconcilable Batch Disposition Percentages Section 4 reports two irreconcilable released unit percentages — 87.4% (narrative) vs. 93.8% (Table 3) — a 6.4 percentage point discrepancy the firm confirmed but could not resolve or correct at inspection. APR Document Error Category Finding Detail Fentanyl Citrate APR Incorrect Product Identification Header All six pages of the Fentanyl Citrate APR carry the header "Annual Product Review: Fentanyl + Bupivacaine," which is the title of a separate APR covering a distinct product family. Fentanyl Citrate + Bupivacaine HCl APR Incorrect Change Control Identifier CC-25-09-004 is referenced in the APR as covering the pool bag extension for all FIDs; the correct identifier is CC-25-09-001. The same incorrect identifier appears across all six APRs reviewed during this inspection. Hydromorphone HCl APR & Morphine HCl APR Identical Typographical Error in NCR Section Both APRs contain the phrase "There was on non-conformance" in Section 8, indicating a shared template was not reviewed for accuracy prior to finalization. Morphine HCl APR Incorrect API Salt Form Identified Section 1 describes compounding a "morphine citrate solution." The correct API salt form is morphine HCl. The error resulted from a copy-paste from another APR and was present in the finalized document. Ropivacaine HCl APR Incorrect Boilerplate Conclusion The conclusions section states "No adverse quality trends, outside of the evaporation over time, were noted." The evaporation-related potency concern is specific to the Hydromorphone HCl CADD product (FID (b)(4)) and does not apply to ropivaca

    Shortened here; the PDF has the full text.

  3. 3

    OOS procedure lacks investigation timelines oversight

    Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. Specifically, Your Out of Specification (OOS) procedure, GMP-SOP-0047 (Out of Specification (OOS) SOP), does not establish defined timeframes for the completion of OOS investigations, including maximum allowable durations for Phase I laboratory investigations or Phase II full-scale investigations, nor does it define criteria or approval requirements governing the use of supplemental justifications to extend investigations beyond an initial target. During the inspection, firm management indicated that investigations typically take approximately (b)(4) days but have extended to approximately (b)(4) days, at which point a supplemental justification is added to the investigation record. Review of 13 OOS investigation records revealed that 9 required extension justifications, with open durations ranging from 35 to 205 days. The two longest investigations — OOS-25-09-004 (205 days, sterility failure, lot 1013-25-08-0005) and OOS-25-09-020 (98 days, sterility failure, lot 1013-25-09-0002) — remained open well beyond the firm's stated (b)(4)-day threshold. Because the SOP does not define completion timelines, extension criteria, or approval requirements, there is no procedural mechanism to ensure investigations are completed in a timely manner or that justifications for delays are evaluated against a consistent, established standard, creating a systemic gap in oversight that may affect the timeliness of batch disposition decisions. OOS Number Description Date Initiated Date Closed Number of Days Open Extension Request Approved? OOS-24-11-001 USP 788 Method I + II failure - lot 104024110001 11/27/2024 2/18/2025 83 days Yes OOS-24-12-001 pH, (b)(4) stability @(b)(4), 100424060001 12/19/2024 2/20/2025 63 days Yes OOS-25-05-003 Low potency - lot 1028-25-04-0009 and 1028-25-05-0001 5/15/2025 6/27/2025 43 days No OOS-25-05-010 Sterility failure - lot 1055-25-05-0001 5/20/2025 6/30/2025 41 days No OOS-25-08-013 Sterility failure - lot 1030-25-07-0005 8/27/2025 10/6/2025 40 days Yes OOS-25-09-004 1013-25-08-0005 sterility failure 9/8/2025 4/1/2026 205 days Yes OOS-25-09-020 Sterility failure - 1013-25-09-0002 9/22/2025 12/29/2025 98 days Yes OOS-25-10-019 Low potency - 4001-25-09-0001 10/23/2025 12/18/2025 56 days Yes OOS-26-03-030 1013-26-03-0001 sterility failure 3/31/2026 5/20/2026 50 days Yes OOS-26-06-017 stability sterility failute - 4011-25-12-0003 6/11/2026 7/16/2026 35 days N/A OOS-26-06-029 Low potency - 1047-01-2606-03 6/26/2026 7/31/2026 35 days Yes

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3014064135, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.