OurPharma LLC
Arkansas
FEI 3014064135
FDA has 3 inspections on file for OurPharma LLC in Arkansas (FEI 3014064135), from 2021 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2021–2026
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Requested under FOIA
- 2 requests, latest Jul 3, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic sterilization in ISO 8 without justification
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, • (b)(4) Sterilization Performed in an ISO 8 Classified Room Batch records collected during the inspection confirm that (b)(4) sterilization was performed in Compounding Room (b)(4) which is classified as ISO 8. Specifically: Batch production records for two lots of Fentanyl Citrate/Bupivacaine HCl combination products, Lot 1019-01-2608-01 (Fentanyl Citrate 2mcg[base]/mL + Bupivacaine HCl 0.125% in (b)(4) added to 100mL 0.9% NaCl Bag; Master Production Batch Record No. GMP-PDTMethods-0218, Revision 01, Effective Date: July 9, 2026) and Lot 1081-01-2608-01 (Fentanyl Citrate 2mcg[base]/mL + Bupivacaine HCl 0.1% in SWFI added to 100mL 0.9% NaCl Bag; Master Production Batch Record No. GMP-PDTMethods-0239, Revision 01, Effective Date: July 15, 2026) — document that (b)(4) of the bulk drug solution was performed in an ISO 8 "(b)(4) storage room" (Compounding Room (b)(4)). Specifically, in both records, Step 1.2 instructs operators to sanitize materials for transfer to this room ((b)(4) Storage room/Compounding Room (b)(4)), Step 1.5 identifies (b)(4) Storage room/Compounding Room (b)(4) as the designated area for these operations, Section 4 (b)(4) Step 4.1 documents that (b)(4) sterilization of the bulk drug solution was performed in this room, and Step 4.4 directs removal of the (b)(4) pool bag from (b)(4) Storage/Compounding Room (b)(4) for transfer to the cleanroom. • No Risk Assessment or Scientific Justification Provided You were unable to provide a risk assessment, quality risk management document, validation study, or any other documented scientific justification supporting the use of an ISO 8 classified environment for (b)(4) sterilization of sterile drug products. No documentation identified that: [ ] Assessed the contamination risks associated with performing these operations outside of an ISO 5 environment; [ ] Evaluated whether ISO 8 conditions are adequate to protect the sterility of the drug product solution during sterilizing (b)(4); or [ ] Demonstrated that the firm identified, evaluated, and mitigated the elevated microbial and particulate contamination risk posed by the ISO 8 environment for these operations.
- Observation 2
Annual product reviews inaccurate and unverified
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Specifically, Annual product review (APR) records for six drug product families — Fentanyl Citrate, Fentanyl Citrate + Bupivacaine HCl, Fentanyl Citrate + Ropivacaine HCl, Hydromorphone HCl, Morphine HCl, and Ropivacaine HCl, covering review period 2024–2025 — contain multiple numerical inconsistencies, cross-product data errors, and documentation inaccuracies. When presented with these findings during the inspection, firm management confirmed that the errors were mistakes and that corrected records had not been issued prior to the inspection. DATA INTEGRITY & STATISTICAL ERRORS APR Document Error Category Finding Detail Fentanyl Citrate + Bupivacaine HCl APR Irreconcilable Batch Disposition Percentages The firm reported three mutually inconsistent released percentages (97.65%, ~96.1%, and 96.5%) and could not identify which figure was correct. Fentanyl Citrate + Bupivacaine HCl APR Inconsistent Unit Denominator Across Reject Categories Table 1 uses an incorrect denominator of 93,573 units — rather than the correct (b)(4) units used for all other reject categories in the same table — to calculate the in-process reject rate, a (b)(4)-unit error the firm acknowledged. Fentanyl Citrate + Bupivacaine HCl APR FID (b)(4) Omitted from OOS and Disposition Trend Data FID (b)(4) was listed as a covered facility but absent from all data tables, creating a potential gap in the annual product review if production occurred. The firm confirmed the omission was accidental. Completeness of data evaluation for FID (b)(4) remains unresolved. Fentanyl Citrate + Ropivacaine HCl APR Mathematical Error in Visual Inspection Reject Table Table 2 understates the "Other Major" reject rate nearly 39-fold (0.05% reported vs. ~1.95% actual), an acknowledged calculation error uncorrected at the time of inspection. Hydromorphone HCl APR Lot Count Data Copied from a Different Product Family Table 4 of the Hydromorphone HCl APR uses Fentanyl Citrate lot counts (b)(4) instead of the correct Hydromorphone HCl total (b)(4); the firm confirmed the error but could not provide correct disposition data at the time of inspection. Hydromorphone HCl APR Irreconcilable Batch Disposition Percentages Section 4 reports two irreconcilable released unit percentages — 87.4% (narrative) vs. 93.8% (Table 3) — a 6.4 percentage point discrepancy the firm confirmed but could not resolve or correct at inspection. APR Document Error Category Finding Detail Fentanyl Citrate APR Incorrect Product Identification Header All six pages of the Fentanyl Citrate APR carry the header "Annual Product Review: Fentanyl + Bupivacaine," which is the title of a separate APR covering a distinct product family. Fentanyl Citrate + Bupivacaine HCl APR Incorrect Change Control Identifier CC-25-09-004 is referenced in the APR as covering the pool bag extension for all FIDs; the correct identifier is CC-25-09-001. The same incorrect identifier appears across all six APRs reviewed during this inspection. Hydromorphone HCl APR & Morphine HCl APR Identical Typographical Error in NCR Section Both APRs contain the phrase "There was on non-conformance" in Section 8, indicating a shared template was not reviewed for accuracy prior to finalization. Morphine HCl APR Incorrect API Salt Form Identified Section 1 describes compounding a "morphine citrate solution." The correct API salt form is morphine HCl. The error resulted from a copy-paste from another APR and was present in the finalized document. Ropivacaine HCl APR Incorrect Boilerplate Conclusion The conclusions section states "No adverse quality trends, outside of the evaporation over time, were noted." The evaporation-related potency concern is specific to the Hydromorphone HCl CADD product (FID (b)(4)) and does not apply to ropivaca
Shortened here; the PDF has the full text.
Show observation 3
- Observation 3
OOS procedure lacks investigation timelines oversight
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. Specifically, Your Out of Specification (OOS) procedure, GMP-SOP-0047 (Out of Specification (OOS) SOP), does not establish defined timeframes for the completion of OOS investigations, including maximum allowable durations for Phase I laboratory investigations or Phase II full-scale investigations, nor does it define criteria or approval requirements governing the use of supplemental justifications to extend investigations beyond an initial target. During the inspection, firm management indicated that investigations typically take approximately (b)(4) days but have extended to approximately (b)(4) days, at which point a supplemental justification is added to the investigation record. Review of 13 OOS investigation records revealed that 9 required extension justifications, with open durations ranging from 35 to 205 days. The two longest investigations — OOS-25-09-004 (205 days, sterility failure, lot 1013-25-08-0005) and OOS-25-09-020 (98 days, sterility failure, lot 1013-25-09-0002) — remained open well beyond the firm's stated (b)(4)-day threshold. Because the SOP does not define completion timelines, extension criteria, or approval requirements, there is no procedural mechanism to ensure investigations are completed in a timely manner or that justifications for delays are evaluated against a consistent, established standard, creating a systemic gap in oversight that may affect the timeliness of batch disposition decisions. OOS Number Description Date Initiated Date Closed Number of Days Open Extension Request Approved? OOS-24-11-001 USP 788 Method I + II failure - lot 104024110001 11/27/2024 2/18/2025 83 days Yes OOS-24-12-001 pH, (b)(4) stability @(b)(4), 100424060001 12/19/2024 2/20/2025 63 days Yes OOS-25-05-003 Low potency - lot 1028-25-04-0009 and 1028-25-05-0001 5/15/2025 6/27/2025 43 days No OOS-25-05-010 Sterility failure - lot 1055-25-05-0001 5/20/2025 6/30/2025 41 days No OOS-25-08-013 Sterility failure - lot 1030-25-07-0005 8/27/2025 10/6/2025 40 days Yes OOS-25-09-004 1013-25-08-0005 sterility failure 9/8/2025 4/1/2026 205 days Yes OOS-25-09-020 Sterility failure - 1013-25-09-0002 9/22/2025 12/29/2025 98 days Yes OOS-25-10-019 Low potency - 4001-25-09-0001 10/23/2025 12/18/2025 56 days Yes OOS-26-03-030 1013-26-03-0001 sterility failure 3/31/2026 5/20/2026 50 days Yes OOS-26-06-017 stability sterility failute - 4011-25-12-0003 6/11/2026 7/16/2026 35 days N/A OOS-26-06-029 Low potency - 1047-01-2606-03 6/26/2026 7/31/2026 35 days Yes
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 503B(a)(10)(B)
Drug product container, fails to include
The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- FDCA 503B(a)(10)(A)
Drug product labels, fails to include
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- FDCA 503B(b)(2)(A)
All inclusive product report, not submitted
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 3, 2025. Each one asked for a Form 483.
Inspection ending Sep 27, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 3, 2025FDA-FOIA-2025-8275Form 483· 1 of 2 sitesClosed over fees
- Dec 17, 2024FDA-FOIA-2024-11075Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 2 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014064135 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014064135. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.