PQ Pharmacy LLC Form 483, June 2026
FDA issued this Form 483 to PQ Pharmacy LLC in Florida (FEI 3017374013) at the end of an inspection that ended June 1, 2026. It lists 7 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 1, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Sep 22, 2026
- 113 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic process and media fill validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, Media Fills A) Your facility failed to follow written procedure S601002, entitled "Validation of Aseptic Processes by Simulation (Media Fill)" version 12 dated 12/02/2025 that requires you to revalidate the media fill process with [illegible] runs if you obtain a turbid unit. On (b)(4) 06/16/2025, a media fill out of specification (OOS) occurred for lot (b)(4) during dropper bottle operations recovering one (1) turbid unit. Your response to this OOS was limited to decertifying the individual suspected of causing the contamination. You did not assess the aseptic integrity of the manufacturing process itself or evaluate its impact on the products you manufacture. B) Your media fill process is deficient as you have not ensured interventions required by the protocol are comprehensive and are simulated by all operators. Additionally, you use (b)(4) vials to simulate your (b)(4) vialing process. You have not evaluated whether turbidity can be adequately detected in these vials. These vials are used to package drug products Phenylephrine/Lidocaine 15mg/10mg/mL (1.5%/1%) 1mL, Moxifloxacin HCL 1mg/mL 1mL, and Moxifloxacin HCL 5mg/mL 1mL. C) Personnel monitoring (PM) conducted following media fill activities is not representative of locations which may contribute to microbial contamination during aseptic operations. For example, PM is limited to, which you identify as (b)(4), while sampling of (b)(4) the head and chest areas are not performed, despite these regions routinely breaching the ISO-5 environment during operations. Process Validation D) You have not performed process validation for any of the sterile drug products you manufacture to demonstrate that the manufacturing processes are in a state of control and capable of consistently producing results with minimal variability between batches. E) You have not adequately validated your hold time process to demonstrate you can effectively store in-process USP grade bulk drug products for the established (b)(4) day time period. For example, for cyclosporine USP, you have not evaluated loss on drying, residual solvents, and related compounds, all elements required by the USP monograph to support drug purity. You do not have scientific rationale for excluding these elements in your study. E: This is a repeat observation from the warning letter issued 10/10/2025. F) On 07/07/2025, your quality unit initiated investigation DEV2025048 in response to a sterility failure Lot (b)(4) (BUD: (b)(4)), Tropicamide/Phenylephrine 10mg/25mg (1%/2.5%) 5mL. The investigation identified the root cause as insufficient tightening of dropper caps during the (b)(4) process thereby implicating (b)(4) units. Despite this determination, the identified defect type was never incorporated into the established defect library or a relevant procedure. Furthermore, you have not implemented and validated an inspection process capable of detecting incompletely tightened dropper caps to adequately address this failure mode.
- 2
Inadequate HEPA filter and HVAC qualification controls
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm has not established adequate procedures and controls for the maintenance, certification, and qualification of HEPA filters, laminar air flow hoods (LAFH), biological safety cabinets (BSC), and cleanroom HVAC systems used for sterile drug production. HVAC failures have recurred without effective corrective action and oversight by the quality unit. For example, A) Your firm has not performed installation and operational qualification (IQ/OQ) for the HVAC systems and HEPA filtered air supply in the hazardous and non-hazardous ISO 7 and 8 cleanrooms, as confirmed by you, the CEO. Additionally, your firm has not established a written procedure governing routine qualification of your facility used in production of sterile drug products. B) According to your Quality Manager, cleanroom, LAFH, and BSC qualification acceptance criteria were not formally established between your firm and your contractor. Your Quality Manager stated test and acceptance criteria are based on industry standards but could not produce documentation of the criteria communicated to your contractor or the basis for their application. C) Your firm's quality unit has failed to thoroughly review preventive and corrective maintenance reports. During review of your firm's work orders of HEPA certifications, records contain unexplained failures, errors, and missing source data. HEPA certification reports for March/April 2025 and October 2025 indicate that a visual smoke pattern test was performed with passing results for all LAFHs, but source documentation from your contractor does not support that these tests were performed. Additionally, leak test results for LAFH and BSC HEPA filters were reported in the March/April 2025 certification report, however, the source data was not included. Your Quality Manager stated that HEPA certification reports provided by your vendor are reviewed by QA but that review is not documented. D) Your firm's hazardous cleanroom HVAC intake HEPA filter failed leak testing in October 2025. In response, your vendor performed a pressure differential ("(b)(4)") test; however, leak testing was not repeated and passing leak test results were not obtained or evaluated by your quality unit. You, the CEO, stated that a passing leak test was not required because the HVAC HEPA filter serves as a redundant filtration step. Your firm's quality unit did not document review of these results or any follow-up actions in response to the failed leak test.
- 3
Inadequate investigations of discrepancies and failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, investigations into failures and adverse circumstances lack the depth necessary to adequately determine root cause. A review of several investigations revealed either unsubstantiated conclusions or a failure to identify root cause, particularly in cases involving repeated occurrences. Examples of these occurrences include but are not limited to: A) DEV2025047, initiated on 07/02/2025 in response to a turbid media fill unit from lot (b)(4) identified "operator error" as the root cause without evaluating potential impacts of other process inputs such as gowning, material sterility and handling, and environmental controls. Additionally, the root cause was attributed to an individual based on speculation, without an established process for tracing the timing of when units were filled/handled. B) DEV2025048 was initiated on 07/07/2025 in response to out-of-specification sterility results recovered from lot (b)(4). This investigation identified loosely applied drop container caps as the root cause, citing the (b)(4) capping process, but failed to identify the reason for the increased defect rate as compared to other lots. Additionally, the investigation scope was not broadened to consider potential impact to other batches manufactured by the same process. This batch was ultimately rejected. C) DEV2026001 was initiated on 02/03/2026 in response to microbial recovery on an operator's sleeve during aseptic filling of lot (b)(4) (Prednisolone Sodium Phosphate/Moxifloxacin HCL/Bromfenac Sodium 1%/0.5%/0.09%). Your investigation concluded "the contamination occurred without evidence of skin exposure," or "procedural non-compliance," despite including evidence that both were contributing factors to the excursion. Per your QA Manager, the investigative efforts have been completed, however, this deviation is currently open pending closure of associated corrective/preventive actions. Its original due date was 03/20/2026 and an extension was issued without a new target due date or approval by Quality Assurance. Deviation remains open, but batch was destroyed. D) Three (3) deviations in 2025 and two (2) deviations in 2026 were initiated to document HVAC failures resulting in out of specification (OOS) temperature and humidity in the ISO 7 cleanrooms. The root causes for each of the events are documented as indicated below. Despite repeated HVAC failures, your quality unit has not initiated preventative actions. Your quality unit released approximately (b)(4) lots of product without verifying HEPA suitability after HVAC repairs. Deviations Date Initiated Root Cause Assigned DEV2025039 05/19/2025 A/C unit for non-hazardous suite was "frozen over" and not working properly. DEV2025050 07/26/2025 control in the ISO Classified areas experienced a mechanical failure. DEV2025053 08/28/2025 Complete failure of the cleanroom AC unit, attributed to advanced coil corrosion, and inadequate preventative maintenance, specifically a lapse in routine inspection and servicing of the HVAC coils. DEV2026005 04/13/2026 inspection the unit where he observed low coolant level. DEV2026006 04/17/2025 [Technician arrived at the facility at 20APR2020 and inspected the unit where he observed a leak in the evaporator coil.] E) Consumer complaint CC-2026-002 was initiated 04/14/2026 for leaking bottles during transport for Prednisolone Sodium Phosphate/Moxifloxacin HCL/Bromfenac Sodium 1%/0.5%/0.09% Lot PMB030426EO BUD: 03/04/2027. Although the complaint was logged and acknowledged, to date, there has been no investigation conducted into the root cause of this issue. Investigation handling is a repeated observation from your warning letter issued 10/10/2025.
- 4
Equipment inspection records not maintained
Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained. Specifically, A) During post-use (b)(4) of the sterilizing (b)(4) used for prednisolone sodium phosphate 1% / moxifloxacin HCl 0.5% / bromfenac 0.09% PF, Lot PMB121525CH BUD 12/15/2026, two (2) consecutive tests resulted in the error message "Error: (b)(4) Not Obtainable"; neither were recorded in the batch record, subjected to (b)(4) (b)(4) operations review, or reviewed by your quality unit. B) Procedure S403400, "Use and Maintenance of (b)(4)" Version 3, dated 12SEP2025, does not address "error" results and provides no instruction for their documentation, escalation, or investigation. C) Quality Assurance does not periodically review audit trails or test results stored in the (b)(4) instrument. Your Quality Manager confirmed these reviews are not performed. D) Procedure S403400, Section 7.9.23 indicates (b)(4) data can be backed up to external storage. However, your CEO confirmed that no backup is performed to prevent data loss.
- 5
Quality unit procedures lack second-person review
The responsibilities and procedures applicable to the quality control unit are not in writing. Specifically, you have not established a procedure to ensure critical data is reviewed and verified by a second person prior to batch release. For example, A) Data generated from environmental monitoring (EM) plates post incubation are read by a (b)(4) (b)(4) and are not subject to a (b)(4) review. Observations interpreted from the original data (EM plates) are recorded on a form that is ultimately reviewed by the quality unit. Your quality unit has no process for reviewing the original data generated from the EM plates for accuracy. B) (b)(4) conducted by Pharmacists are not subject to (b)(4) review prior to evaluation by the quality unit. According to your written procedure S403400, titled "Use and Maintenance of (b)(4)" version 3 dated 09/12/2025, (b)(4) electronic signatures are required to document and verify the performance for each (b)(4) test performed using the (b)(4) instrument. Your Operations Manager/Pharmacist stated that Pharmacists are exempt from the (b)(4) review. "99%" of all non-hazardous (b)(4) An example of this includes Prednisolone Sodium Phosphate/Moxifloxacin HCl/Bromfenac 1%/0.5%/0.09% Lot: PMB121525CH BUD: 12/15/2026 was a released product reviewed.
- 6
Aseptic and visual inspection procedures not followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed. Specifically, Visual Inspection Operations You have not ensured that operators conducting 100% (b)(4) visual inspection are capable of identifying all defined visible defects across your sterile drug product containers, including vials, syringes, and eye drop containers. This is evidenced by: A) During the walk-through of your facility on 04/28/2026, we identified what appears to be bubbles in the plunger threads of syringe when reviewing the units used to qualify your visual inspection operators. Upon inquiry with your visual inspection operators, it was determined that this occurrence had neither been identified nor recognized as a potential defect type for the syringe product manufactured at your facility. The product manufactured in the syringe is Mitomycin 1mg/mL 40mL. Syringe products, when distributed, are shipped via (b)(4), which may involve (b)(4) transport. B) Your visual inspection defect limit acceptance criteria and criticality are not scientifically justified. Per written procedure S700360, "Particulate and Defect Inspection Procedure for All Sterile Products", Revision 3, dated 02/27/2026, applies a (b)(4) and limit for critical, major and minor defects, respectively, to all products you manufacture. You have not performed a risk assessment to determine which defects are critical, major, or minor. For example, a (b)(4) defect limit is applied to all particulate defects, regardless of type (e.g., intrinsic, extrinsic). Additionally, your Quality Manager stated defect limits were established based on (b)(4); they are not adjusted based on (b)(4). Aseptic Operations C) Your smoke study evaluations of your ISO-5 environments are inadequate, as they fail to simulate airflow patterns across all high-risk areas under representative operational conditions. For example, during the simulations, materials such as stacks of environmental monitoring (EM) plates and an air sampler were positioned at the (b)(4) of the hood, obstructing the recirculation vents. Because these areas were not evaluated, the smoke studies do not adequately characterize airflow behavior in the vicinity of these materials, leaving critical zones unassessed. These smoke studies are intended to simulate the production of sterile drug products manufactured in your facility. C: This is a repeated observation from your warning letter issued 10/10/2025.
- 7
Laboratory controls lack impurity and identity testing
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug product containers conform to appropriate standards of identity, strength, quality and purity. Specifically, A) Your finished product testing used to release finished drug products for commercial distribution and perform stability testing does not include an evaluation of impurities and degradants. B) You do not have a scientific rationale for not performing identity testing for glycerin and propylene glycol, which includes evaluating acceptable levels of diethylene glycol and ethylene glycol. These components used in part for the manufacture of sterile drug products.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3017374013, newest first.
- Form 483, April 2025Inspection ended Apr 4, 2025 · Posted May 7, 2025OAI
- Form 483, October 2022Inspection ended Oct 27, 2022 · Posted Jan 30, 2023VAI
- Amended Form 483, October 2022Inspection ended Oct 27, 2022 · Posted Jun 21, 2023VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.