Victory Medical Center Pharmacy Form 483, September 2026
FDA issued this Form 483 to Victory Medical Center Pharmacy in Texas (FEI 3010485868) at the end of an inspection that ended September 10, 2026. It lists 11 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 21, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 10, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Oct 21, 2026
- 41 days after the inspection
The 11 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Dietary supplement grade APIs for sterile drugs
Use of ingredients not intended for pharmaceutical use in sterile drug production. Specifically, the following was observed, but not limited to: 1) On August 31, 2026, the following dietary supplement grade APIs were observed in your firm's raw material storage area and confirmed to be in use for sterile drug product production: [illegible], USP, Lot (b) (4), Expiration Date (b) (4), (b) (4), Lot (b) (4), Expiration Date (b) (4), (b) (4), Lot (b) (4), Expiration Date (b) (4), (b) (4). Each API is labeled as dietary supplement grade. On August 31, 2026, your firm was directly observed using the above-referenced dietary supplement grade APIs to aseptically produce ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026. 2) On July 16, 2026, your firm used the following dietary supplement grade APIs to aseptically produce B COMPLEX (MDV) DEXPAN/NIACINAMIDE/PYRIDOX HCL/RIBO-5-PHOS/THIAMINE HCL (2/100/2/2/100) STOCK SOLUTION, Lot 2018604, BUD December 13, 2026: Pyridoxine HCl, USP (Vitamin B6), dietary supplement grade, Lot (b) (4), Expiration Date (b) (4); Thiamine HCl, USP (Vitamin B1), dietary supplement grade, Lot (b) (4), Expiration Date (b) (4); Magnesium Chloride, USP (Hexahydrate), dietary supplement grade, Lot (b) (4), Expiration Date (b) (4). This stock solution was further used as a component in the production of (b) (4) - 50mL vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026. (b) (4) - 50mL vials were dispensed on (b) (4). 3) On July 24, 2026, your firm used the following dietary supplement grade API to aseptically produce TIRZEPATIDE/NIACINAMIDE (MDV) 20/2MG/ML STOCK SOLUTION, Lot 2024973, BUD October 22, 2026: Niacinamide, USP, dietary supplement grade, Lot (b) (4), Expiration Date (b) (4). This stock solution was further used to produce (b) (4) - 1 mL syringes of TIRZEPATIDE/NIACINAMIDE (MDV) 20/2MG/ML, Lot 2025318, BUD October 22, 2026. 1mL syringes were subsequently dispensed on (b) (4). 4) On May 29, 2026, your firm used the following dietary supplement grade API to aseptically produce (b) (4) of GLUTATHIONE (MDV) 200MG/ML STOCK SOLUTION, Lot 1980219, BUD August 27, 2026: Glutathione, USP ((b) (4)) (Dietary Supplement Grade), Lot (b) (4), expiration date (b) (4). This stock solution was further used as a component in the production of the following sterile drug products: (b) (4) - 30ml vials of GLUTATHIONE (MDV) 200MG/ML 30ML, Lot 1981940, BUD August 27, 2026; (b) (4) - 30ml vials of GLUTATHIONE (MDV) 200MG/ML 30ML, Lot 190571, BUD August 27, 2026; (b) (4) - 30ml vials of GLUTATHIONE (MDV) 200MG/ML 30ML, Lot 1984345, BUD August 27, 2026. All 3 lots were dispensed. Several confirmed patient illnesses were linked to GLUTATHIONE (MDV) 200MG/ML STOCK SOLUTION, Lot 1980219, BUD August 27, 2026 and testing confirmed a positive result for endotoxin in GLUTATHIONE (MDV) 200MG/ML 30ML, Lot 1984345, BUD August 27, 2026.
- 2
Uncleanable caulking and gaps in ISO 5 hood
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, on August 31, 2026, the following deficiencies were observed on your firm's (b) (4) ISO 5 Laminar Airflow Hood: (b) (4) Caulking material was observed applied along the frame edges of the HEPA filter housing within your Laminar Airflow Hood (LAFH). The caulking exhibited the following defects: Uneven and irregular application - The caulking was applied unevenly along the frame seams, resulting in inconsistent thickness and width, with visible ridges, valleys, and surface irregularities. These surface irregularities cannot be adequately cleaned or disinfected and provide sites where microbial contamination, cleaning solution residue, and particulate matter can accumulate and persist despite cleaning efforts. Rough and porous surface texture - The caulking surface was visibly rough and non-smooth in texture. A porous, rough surface within an ISO 5 critical zone is inherently incompatible with the cleanliness requirements of a sterile environment, as it cannot be effectively wiped down or disinfected and can harbor microbial contamination within its surface irregularities. Discoloration and signs of degradation - The caulking exhibited visible discoloration and signs of aging and chemical degradation, consistent with prolonged exposure to cleaning and disinfecting agents. Degraded caulking material is prone to cracking, flaking, and shedding, generating particles that can directly contaminate the critical production area and the sterile drug products prepared within it. Separation and cracking from the frame surface - The caulking appeared to be pulling away from and separating from the frame surface in areas, creating open crevices that cannot be cleaned or disinfected and that serve as harborage points for microbial contamination and a source of particle generation within the ISO 5 environment. I observed a (b) (4) located inside your firm's (b) (4) ISO 5 Laminar Airflow Hood (LAFH). The (b) (4) creates gaps along the sides and back of the hood interior. These gaps are not readily accessible for cleaning and disinfection. Your firm's (b) (4) ISO 5 (b) (4) Laminar Airflow Hood is the only ISO 5 LAFH at the facility, and all sterile drug products are aseptically (b) (4) and filled exclusively within this hood.
- 3
Touching sterile container and closure surfaces
Personnel were observed manually contacting the inner surface of a sterile container or closure. Specifically, the following observations were made: 1) During the aseptic production on August 31, 2026 of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026, the following aseptic processing techniques were directly observed: Your firm's sterile technician was observed reaching into a bag of rubber stoppers with a gloved hand to retrieve individual stoppers for placement onto vials. During this retrieval, the sterile technician was observed directly touching the inner surface (product contact area) of the rubber stoppers with their gloved hand. Your firm's sterile technician was observed pouring rubber stoppers directly from the bag onto the surface of the work bench and then using a gloved hand to retrieve individual stoppers from the bench surface for placement onto vials. 2) On September 1, 2026, during the aseptic production of TIRZEPATIDE/L-CARNITINE (25/50MG/ML) STOCK SOLUTION, Lot 2057705, BUD November 1, 2026, your firm's sterile technician was observed reaching into a bag containing syringes used for filling with a gloved hand. The syringes were not oriented within the bag in a manner that would prevent direct contact with the product contact surfaces of the syringes during retrieval.
- 4
Lower quality air influx into classified areas
The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air. Specifically, Your firm's (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH) is designed in a manner that potentially exposes sterile drug products and sterile containers/closures to air of a lower than ISO 5 classification. For example, I observed an air intake vent is located directly behind the sterile technician's working area inside of the ISO 5 LAFH. This vent has not been monitored for unidirectional airflow and is not included in your firm's (b) (4) environmental monitoring sampling program. On August 31, 2026, I observed open and exposed vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2055939, waiting to be stoppered, and exposed rubber stoppers directly in front of the air intake vent. I observed that your firm's (b) (4) connecting the unclassified space to the ISO 8 buffer room lacks a HEPA filter. This design allows unfiltered, lower-quality air from the unclassified space to enter the ISO 8 ante room.
- 5
Inadequate sterilizing filtration exceeding capacity
The (b) (4) intended to render final product sterile is not adequate and not appropriate for pharmaceutical use. Specifically, your firm uses the (b) (4) as its final product (b) (4). According to manufacturer's specifications, (b) (4) has a recommended maximum (b) (4) volume of (b) (4). The following examples demonstrate your failure to adhere to this specification: [illegible] SEMAGLUTIDE/L-CARNITINE (5/50MG/ML) STOCK SOLUTION, Lot 2059406, BUD [illegible] September 3, 2026, I observed your firm's personnel using a (b) (4) [illegible] exceeding the manufacturer's [illegible] ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026 [illegible] ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026, with only one (b) (4) [illegible] (b) (4) of (b) (4) solution (b) (4) documented for (b) (4) testing. (b) (4) rated for (b) (4) [illegible] exceeds the manufacturer's recommended (b) (4) volume. [illegible] solution, (b) (4) maximum (b) (4) of (b) (4) solution; (b) (4) of (b) (4) record for this lot. When asked, your firm's personnel stated they would have to rely on memory to recall how many (b) (4) were used during (b) (4) of this lot. ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026, was used to fill (b) (4) - 49ml vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2027642, BUD October 15, 2026. (b) (4) vials were dispensed on (b) (4).
- 6
No post-use filter integrity testing
Failure to conduct post-use (b) (4) testing on (b) (4) used to sterilize drug products. Specifically, but not limited to, the following examples were observed: ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026, Qty (b) (4) - No documented (b) (4) test was found in the batch record for this lot. ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026, was used to fill (b) (4) - 49ml vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2027642, BUD October 15, 2026. (b) (4) vials were dispensed on (b) (4). ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2055939, BUD October 20, 2026, Qty (b) (4) - Only one (b) (4) test is documented in the batch record; however, your firm's personnel stated that multiple (b) (4) were used during the (b) (4) of this lot. There is no documentation to account for (b) (4) testing of each (b) (4) used. I observed your firm's sterile technician used more than one (b) (4) during production. SEMAGLUTIDE/L-CARNITINE (2.5/25MG/ML) STOCK SOLUTION, Lot 2028524, BUD October 27, 2026, Qty (b) (4) - No documented (b) (4) test was found in the batch record for this lot. SEMAGLUTIDE/L-CARNITINE (2.5/25MG/ML) STOCK SOLUTION, Lot 2028524, BUD October 27, 2026, was used to fill (b) (4) - 1ml syringes of ELITE SLIM 0.4MG (0.16ML PER SYRINGE), Lot 2030230, BUD October 27, 2026, and (b) (4) - 2ml vials of ELITE SLIM 2.5MG/ML (MDV), Lot 2047285, BUD October 17, 2026. 1ml syringes were dispensed on (b) (4). Your firm's personnel stated that they would have to rely on memory to recall whether a (b) (4) test was performed.
- 7
Failure to clean ISO 5 equipment surfaces
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, the following deficiencies were observed: The sterile technician failed to clean the sides and back surfaces of the (b) (4) located inside of the ISO 5 LAFH. The sterile technician failed to clean in between the grates of the vent located (b) (4) the (b) (4). These deficiencies were observed on the following occasions: Between production of TIRZEPATIDE/L-CARNITINE (25/50 MG/ML) STOCK SOLUTION, Lot 2057051, and ZINC SULFATE (MDV) 10 MG/ML STOCK SOLUTION, Lot 2057427, on September 1, 2026; end of day cleaning on September 1, 2026; and end of day cleaning on September 3, 2026.
- 8
Lack of routine environmental monitoring
Lack of routine environmental monitoring in the ISO 5 area and classified areas. Specifically, the following deficiencies were observed: 1) Absence of Historical Surface Sampling Data - Your firm was unable to provide surface sampling environmental monitoring data for your ISO 5 Laminar Airflow Hood (LAFH) and classified cleanrooms prior to July 29, 2026. Despite this absence of surface sampling data, between June 5, 2026 and July 28, 2026, your firm produced (b) (4) different sterile stock drug solutions intended to be filled into vials or syringes and distributed to patients. For example, on July 27, 2026, your firm produced (b) (4) of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML) STOCK SOLUTION, Lot 2026504, BUD October 15, 2026, and filled (b) (4) - 50 mL vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2027642, BUD October 15, 2026. Of those (b) (4) vials, (b) (4) vials were dispensed to patients on (b) (4). 2) Inadequate Surface Sampling of the ISO 5 LAFH - Insufficient Sampling Locations - According to your firm's personnel and the hood recertification records, only one location within the ISO 5 Laminar Airflow Hood is sampled during surface sampling. 3) Failure to Monitor the (b) (4) - Your firm does not perform surface sampling environmental monitoring of the (b) (4) connecting the unclassified laboratory area to the ISO 8 ante room.
- 9
Sterile wipes exposed to lower quality air
Sterile drugs and Materials were exposed to lower than ISO 5 quality air. Specifically, sterile wipes used to disinfect your firm's (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH) were staged open and exposed to lower than ISO 5 quality air prior to use. On August 31, 2026, sterile wipes were observed staged open and exposed on a (b) (4) in the ISO 7 cleanroom. These wipes were subsequently used to disinfect the firm's (b) (4) ISO 5 (b) (4) LAFH. According to firm personnel, sterile wipes are regularly removed from their (b) (4) packaging and stored open in the ISO 7 cleanroom prior to being used to disinfect the ISO 5 LAFH.
- 10
Inadequate media fills for aseptic operations
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, the following deficiencies were observed: Media Fill Volume Does Not Represent Worst-Case Production Conditions - According to your firm's media fill records, your firm (b) (4) of solution and fills [illegible] control vials during media fills. However, your firm's personnel stated that the largest batch size in actual production is (b) (4) syringes. On August 31, 2026, I observed personnel aseptically (b) (4) ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2056424 and fill (b) (4) - 50ml vials of ELECTRO B COMPLEX (MDV) MAGNESIUM CHLORIDE/CALCIUM CHLORIDE/B COMPLEX/SODIUM BICARBONATE (105MG/28MG/B-COMPLEX,12MG/ML), Lot 2056424 during routine operations. Media Fill Container Type Does Not Represent Current Practice - Your firm's media fills are conducted by filling vials only; however, your firm's personnel stated that actual production includes filling syringes, with the largest batch size of (b) (4) syringes. On September 1, 2026, I observed your firm's sterile technician fill TIRZEPATIDE/L-CARNITINE (25/50MG/ML), Lot 2057051, BUD November 1, 2026 into (b) (4) - 1mL syringes. According to your firm's personnel, your final containers include 5ml, 30ml, and 50ml vials, and 1ml syringes. Initial Media Fills for Personnel Not Performed in Triplicate.
- 11
No dynamic smoke studies performed
Smoke studies were not performed under dynamic conditions. Specifically, your firm failed to perform airflow visualization (smoke study) testing under dynamic operating conditions for your (b) (4) ISO 5 (b) (4) Laminar Airflow Hood (LAFH), which is used for the preparation of sterile drug products. No smoke study videos or written protocols exist demonstrating that airflow visualization testing had been performed under dynamic conditions in the ISO 5 LAFH. Your recertifying company reported that a smoke study was performed April 14, 2026; however, your firm's personnel stated they had no knowledge of smoke studies ever having been performed in the ISO 5 LAFH.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.