Skip to content

Pharmaneek Inc

Indiana

FEI 3014484244

FDA has one inspection on file for Pharmaneek Inc in Indiana (FEI 3014484244). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jun 9, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate containment and cleaning

      Hazardous drugs were produced without providing adequate containment segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The current cleaning process is deficient for the following reasons and does not provide assurance that hazardous drug product residue and cleaning agent residue are adequately removed from reusable glassware and utensils used in production of both non-hazardous and hazardous drug products: • On 03/30/2026 following the production of non-sterile hazardous drug Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260 (Beyond Use Date (BUD): 04/29/26), the reusable utensils (such as mortar and pestle and graduated cylinders) and a disposable weigh boat, utilized for production, were cleaned with [(b) (4)] liquid and a reusable [illegible]. No deactivating agent is currently employed to ensure the inactivation and removal of hazardous drug residue from product contact surfaces and utensils. • The reusable washed utensils such as mortar and pestle and the disposable weigh boat, that were used for hazardous drug production, were subsequently observed as being placed in a shared bin containing separate utensils, such as mortar and pestles, which are used for non-sterile non hazardous production activities. • A technician was observed washing a disposable weigh boat that had been used to collect powder from Hydroxyurea Capsules USP, 500 mg, which was subsequently used in the production of non sterile hazardous drug Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260, and placing it in the same container containing utensils such as mortar and pestles used for non hazardous production activities. • Graduated cylinders, used during production of Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260, were returned to storage in a closed cabinet immediately after washing, while water droplets remained visible on the cylinders.

    2. Observation 2

      Unverified water quality for production

      Your firm failed to confirm that the quality of water was suitable for its intended use in the production of non-sterile drug products. Specifically, The firm used [(b) (4)] water for the production of non-sterile drug products, including but not limited to Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010330260 (Date Made: 03/30/26, BUD: 04/29/26), Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010327260 (Date Made: 03/27/26, BUD: 04/26/26) and Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010319260 (Date Made: 03/19/26, BUD: 04/28/26). The firm had no data to demonstrate that the water used met the specifications for [(b) (4)] Water USP. The formula worksheet for Hydroxyurea 100 mg/mL Oral Suspension includes (b) (4) Water USP as an ingredient, but the firm used [(b) (4)] water.

    Show observation 3
    1. Observation 3

      Damaged ceiling exposing plenum

      Your facility is not maintained in a good state of repair, creating insanitary conditions whereby drug products may be contaminated with filth. Specifically, On 03/30/2026, a ceiling tile in the control room where Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010330260 (Date Made: 03/30/26, BUD: 04/29/26) was produced, and subsequently dispensed to the patient, was observed to be chipped, with part of the ceiling tile missing and opened to the plenum space, potentially exposing the room to environmental contaminants.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jun 9, 2026. It asked for a Form 483.

  • Inspection ending Apr 8, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 9, 2026FDA-FOIA-2026-5644Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014484244 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014484244. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.