The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate containment and cleaning
Hazardous drugs were produced without providing adequate containment segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The current cleaning process is deficient for the following reasons and does not provide assurance that hazardous drug product residue and cleaning agent residue are adequately removed from reusable glassware and utensils used in production of both non-hazardous and hazardous drug products: • On 03/30/2026 following the production of non-sterile hazardous drug Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260 (Beyond Use Date (BUD): 04/29/26), the reusable utensils (such as mortar and pestle and graduated cylinders) and a disposable weigh boat, utilized for production, were cleaned with [(b) (4)] liquid and a reusable [illegible]. No deactivating agent is currently employed to ensure the inactivation and removal of hazardous drug residue from product contact surfaces and utensils. • The reusable washed utensils such as mortar and pestle and the disposable weigh boat, that were used for hazardous drug production, were subsequently observed as being placed in a shared bin containing separate utensils, such as mortar and pestles, which are used for non-sterile non hazardous production activities. • A technician was observed washing a disposable weigh boat that had been used to collect powder from Hydroxyurea Capsules USP, 500 mg, which was subsequently used in the production of non sterile hazardous drug Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260, and placing it in the same container containing utensils such as mortar and pestles used for non hazardous production activities. • Graduated cylinders, used during production of Hydroxyurea 100 mg/mL Oral Suspension Lot HU10010330260, were returned to storage in a closed cabinet immediately after washing, while water droplets remained visible on the cylinders.
- 2
Unverified water quality for production
Your firm failed to confirm that the quality of water was suitable for its intended use in the production of non-sterile drug products. Specifically, The firm used [(b) (4)] water for the production of non-sterile drug products, including but not limited to Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010330260 (Date Made: 03/30/26, BUD: 04/29/26), Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010327260 (Date Made: 03/27/26, BUD: 04/26/26) and Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010319260 (Date Made: 03/19/26, BUD: 04/28/26). The firm had no data to demonstrate that the water used met the specifications for [(b) (4)] Water USP. The formula worksheet for Hydroxyurea 100 mg/mL Oral Suspension includes (b) (4) Water USP as an ingredient, but the firm used [(b) (4)] water.
- 3
Damaged ceiling exposing plenum
Your facility is not maintained in a good state of repair, creating insanitary conditions whereby drug products may be contaminated with filth. Specifically, On 03/30/2026, a ceiling tile in the control room where Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010330260 (Date Made: 03/30/26, BUD: 04/29/26) was produced, and subsequently dispensed to the patient, was observed to be chipped, with part of the ceiling tile missing and opened to the plenum space, potentially exposing the room to environmental contaminants.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.