Spectrum Laboratory Products Inc. Form 483, March 2026
FDA issued this Form 483 to Spectrum Laboratory Products Inc. in Gardena, California (FEI 2020632) at the end of a drug inspection that ended March 20, 2026. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 16, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 20, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 16, 2026
- 241 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Quality unit failed to document lab cleaning
Your quality unit failed to record, review, and approve all appropriate quality-related documents at the time activities are performed. Specifically, During my inspection, I reviewed your Laboratory Cleaning Records (QAF877) for all available months in 2025 and 2026. These records are used to document laboratory cleaning activities as required by your SOP QC-W-8.22, Section 5.9, which states: "(b)(4) cleaning activities shall be documented in QAF877, Laboratory Cleaning Record and reviewed (b)(4) by QC Leadership." I observed the following deficiencies: a) Missing Records: Laboratory Cleaning Records for January 2025 and February 2025 were not available for review. Your management stated they suspect these records were not completed. b) Incomplete Documentation: From March 2025 through March 2026, there were numerous instances where cells were marked "N/A [initials] [date]" without adequate explanation. Your management identified these entries as indicating a lack of evidence that cleaning activities occurred.
- 2
Unclean lab hoods and inadequate cleaning procedures
Your firm failed to properly maintain buildings, facilities, and equipment used in the manufacture of intermediates and APIs in a clean condition, and failed to establish adequate written procedures for cleaning equipment. Specifically: a) Laboratory Hood Cleanliness: During my walk through on 3/17/2026 of your laboratory facilities, I observed analytical hoods where testing is performed to be in an unclean condition. The hoods exhibited corrosion, permanent staining, flaking paint, and accumulation of residue and dust. These hoods are used for reagent preparation and analytical testing of APIs and raw materials. The condition of these hoods presents a potential risk of contamination to materials and test results. b) Inadequate Cleaning Procedures: Your SOP QC-W-8.22, "Analytical Laboratory Cleaning," does not specify approved cleaning agents or sanitizing agents for use in the laboratory. The selection of appropriate cleaning agents is left to individual chemist discretion. Your quality management stated that (b)(4) and (b)(4) are primarily used to clean all chemicals, but this is not documented in your written procedures.
- 3
Inadequate cleaning validation and periodic monitoring
Your firm failed to adequately validate written procedures for cleaning and maintenance of equipment, and failed to monitor cleaning procedures at appropriate intervals after validation. Specifically: a) Outdated Cleaning Validation: Your last cleaning validation for production areas was performed in 2001, representing a 25-year gap between validations. This validation may not be representative of the current operations, products, equipment, and cleaning procedures in your facility. b) Incomplete Current Validation: Your firm provided Document Control Number PJ24-005, titled "Packing and Sampling Rooms Cleaning Validation Protocol," with an Effective Date of 10/14/2024. However, your firm was unable to provide the final validation report demonstrating the efficacy of the cleaning procedures, as the validation has not been completed. Analytical data has been collected, but the final report is still being drafted. c) Lack of Periodic Monitoring: There is no documented evidence that cleaning procedures have been monitored at appropriate intervals following the 2001 validation to ensure these procedures remain effective during routine production operations.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.