Aurorium LLC Form 483, March 2026
FDA issued this Form 483 to Aurorium LLC in Midlothian, Texas (FEI 1628757) at the end of a drug inspection that ended March 6, 2026. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 6, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 13, 2026
- 129 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Poor facility maintenance and corrosion
OBSERVATION 1 Failure to properly maintain buildings, facilities and equipment used in the manufacture of active pharmaceutical ingredients (API). Specifically, a) During our walk-through of the manufacturing facility on March 2 and 3, 2026, we noted there were areas of the building that had excessive corrosion, water leaking from equipment, and deterioration of walls and floors. Examples include the following. + We observed water leaking from a pipe that went from the (b) (4) to the (b) (4) ((b) (4) (b) (4) « The platform where the (b) (4) is located is deteriorating and has excessive corrosion. * The wall between the (b) (4) room and production has water damage and is warped and the panels are separating. On the side in the (b) (4) room there is exposed insulation from a large hole in the corner of the room near the (b) (4) and (b) (4) tanks. * We observed a leak on the (b) (4) unit and the metal support for the skid had excessive corrosion. « There were remnants of an old platform on the (b) (4) platform area (b) (4) where the concrete had broken into pieces. « There is water leaking from the exhaust for the dryer. b) On March 3, 2026, we observed the presence of a clear tape placed around a phalange connection on the (b) (4). The system is under (b) (4); (b) (4) can enter the system. The (b) (4) system (b) (4) (b) (4). c) Tank P* used to store (b) (4) from the (b) (4) that will be (b) (4) tanks is not completely covered and is open to the environment.
- 2
Failure to investigate OOS endotoxin
OBSERVATION 2 Failure to investigate all out of specification test results. Specifically, a review of (b) (4) test results from March 2024 to February 2026 revealed four (4) instances where your firm received an out of specification test result for endotoxins. Your firm has no documentation to show that these out of specification test results were investigated nor did you perform any product impact assessment. Per MIDL-SOP-307 (b) (4), effective January 1, 2024, the specification for endotoxin is (b) (4) EU/mL. + Sample from (b) (4) system collected 05/29/2024 - test result was 0.430 EU/mL « Sample from (b) (4) system collected 09/25/2024 - test result was 1.508 EU/mL « Sample from (b) (4) system — QC Laboratory collected 09/25/2024 - test result was 0.439 EU/mL « Sample from (b) (4) system — QC Laboratory collected 03/31/2025 - test result was 17.589 EU/mL « Sample from (b) (4) system collected 05/27/2025 - test result was 0.418 EU/mL In addition, several of the lab reports for the testing of the (b) (4) indicate that the sample for endotoxin testing was received outside of the recommended temperature range. The laboratory report does not state the temperature the samples were received at nor does it state what the recommended temperature range is. There is no evaluation of this issue to determine if it has any impact on testing of the (b) (4) to receive accurate results.
- 3
Quality Unit oversight failures
OBSERVATION 3 Failure of the Quality Unit to fulfill its oversight responsibilities. Specifically, a) CAPAs are not fully documented in accordance with your established procedure entitled Corrective and Preventative Actions (MIDL-SOP-124) effective January 1, 2024; they also are not closed out in a timely manner. For example: + CP25-014 (initiated 8/15/2025), CP25-010 (initiated 7/01/2025), CP25-019 (initiated 11/17/2025), CP24-12 (initiated 10/11/2024), and CP24-13 (initiated 9/24/204), either lack or have insufficient documentation of an effectiveness check. + CP24-12, CP24-13 and CP25-019 have not been finalized and signed off as completed or reviewed by quality. b) Your firm does not have written procedures for the issuance, use and reconciliation of loose-leaf forms used for documentation of manufacturing (e.g. batch record) and laboratory testing. Examples of these forms include: + All forms and documents that are part of the batch record « Form 239A Reagent/Solution Preparation Log * Form 120A Label Control Form « Form 121A Label Issuance + Form 112B Pre-Shipment Review Log + Form 133D Total Unacceptable (b) (4) Count c) There is a failure to review and approve all quality-related documents. The analytical testing lab books (data collection form) used for testing of (b) (4), USP (API) are not controlled documents. The documents are not assigned numbers or revisions nor have they been reviewed and approved by the Quality Unit. These forms include the following: * USP/FCC/JP Chemistry Testing of (b) (4) * USP/FCC/EP/JP Loss on Drying of (b) (4) + USP/FCC/EP/JP Equivalent (b) (4) Test for (b) (4) * (b) (4) and Morphology d) Your firm has no written SOP governing the circumstances that would warrant the creation of a work order to ensure that all maintenance of equipment is reported. For example, on March 3, 2026, we observed the presence of a clear tape placed around a phalange connection on the (b) (4). No work order has been initiated to fix the issue and your firm has no documentation to show how long the tape has been on the equipment and who made the decision to do so. e) There is a failure of the Quality Unit to appropriately review all (b) (4) test results. « There is no documented Quality Unit review of the results from August 2025 to present. « From March 2024 to February 2026 there were four (4) instances of out of specification results for endotoxin that were not investigated however, the Quality Unit documented that the results were reviewed.
- 4
Missing annual product quality review
OBSERVATION 4 Your firm failed to conduct an annual product quality review of your API. During the current inspection of your facility we observed that you had not conducted your 2024 annual product quality review for your API (b) (4), USP. On August 6, 2025, your firm initiated a deviation report however, no content was provided in the report explaining why the 2024 review had not been completed or when it would be finalized. The deviation is still open.
- 5
Lack of required material testing
OBSERVATION 5 Failure to perform testing of the (b) (4) used in production and in the QC Laboratory. Specifically, your firm could not provide test results for the (b) (4) for the (b) (4) of (b) (4) and (b) (4). MIDL-SOP-307 (b) (4), effective January 1, 2024 requires (b) (4) testing of the (b) (4) for (b) (4), endotoxin, and microbial (standard plate count and pseudomonas). In addition, your firm has no documentation and/or procedure to show exactly where the samples are being taken by your 3rd party contractor. The laboratory results simply state (b) (4), "Lab" and "Production."
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.