Skip to content

ChemPacific Corporation Form 483, April 2026

FDA issued this Form 483 to ChemPacific Corporation in Baltimore, Maryland (FEI 3003299802) at the end of a drug inspection that ended April 7, 2026. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 23, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 7, 2026
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 23, 2026
199 days after the inspection
Facility
FEI 3003299802
Baltimore, Maryland

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate quality and data integrity controls

    The firm failed to maintain adequate quality control systems, including data integrity controls and procedural oversight, Specifically, a. Your firm failed to ensure that laboratory records include complete data derived from all tests conducted on GMP materials and failed to maintain adequate documentation of laboratory testing activities. Review of HPLC sample injection testing data from instruments (b)(4) and (b)(4) (software: (b)(4)) revealed that analysts performed 35 undocumented HPLC sample injections on GMP materials under the non-GMP testing project name "test" and the GMP testing project name (b)(4) between April 2023 and December 2024. Both instruments are used for testing GMP and non-GMP samples. This practice is also performed on the firm's other laboratory equipment: GC, IR/UV, and (b)(4). For example, analysts conducted sample testing without recording the activities in laboratory logbooks and analyst notebooks. The undocumented analyses fall into the following categories with the reasoning behind each injection: [illegible table - claimed purpose, material, injections, date, category including system suitability, condition check, analysis, testing, column check entries dated 04/23/2023, 04/27/2023, 08/16/2023, 08/28/2023, 06/13/2024, 12/18/2024]. Your firm's laboratory practices demonstrate a failure to maintain complete and accurate documentation of analytical testing performed on GMP materials. b. Your firm failed to establish adequate written procedures and controls for chromatographic peak (b)(4) integration used in assay and impurity testing of drug products, including intermediates and final API testing of (b)(4). Specifically, the firm lacks written procedures that establish limitations and criteria for peak area selection during manual integration of chromatographic data. For example, analysts perform manual integration for intermediates, final API assay, and impurity testing without documented procedures governing when and how manual integration should be applied. As a result, manual integration practices may vary among analysts due to the absence of standardized procedures and controls. The lack of standardized procedures for chromatographic peak integration creates significant risks to data integrity and product quality. c. Batch production and control records are not prepared at the time each action is taken, and entries are not signed in a timely fashion. On 03/30/2026, during the walkthrough of Room (b)(4) where Stage (b)(4) production of the intermediate (b)(4) lot (b)(4) (sub lot (b)(4)) being performed, it was observed that data was entered and signed by the operator in the batch record; however, the checker signature field was left blank. The chemist conducting the production stated that he "signs as the operator and that the checker will usually sign later because they trust each other." This demonstrates systemic documentation issues in which: 1) Batch record entries are not being signed at the time the action is performed or verified; 2) The independent verification system is not functioning as designed; and 3) Batch records do not provide contemporaneous documentation of manufacturing operations.

  2. 2

    No ongoing API stability testing program

    The firm failed to have an ongoing testing program designed to monitor the stability characteristics of active pharmaceutical ingredients. Specifically, Your firm has not performed an ongoing stability testing program that is established to monitor the stability characteristics of API (b)(4) to establish or verify retest dates. For example: Your firm manufactured (b)(4) batches of API in (b)(4) (batches (b)(4)). Although these batches have been tested and approved for release, they have not been placed on stability studies.

  3. 3

    Improper material storage and segregation controls

    Materials are not handled and stored in a manner to prevent contamination and ensure proper identification. Additionally, there is inadequate separation between materials of different statuses. Specifically, Your firm does not have material log-in records for your refrigerators and freezers used to store critical production materials. On March 30, 2026, during a facility walkthrough, it was observed that the firm stores intermediates in refrigerators and freezers (b)(4) but could not demonstrate adequate knowledge of the materials stored in specific units. For example, an unidentified bag of failed research and development intermediate IM-(b)(4) was found in Freezer (b)(4), which is also used to store GMP intermediates for (b)(4) production. The firm was unable to explain the reason for storing this material in the freezer or the duration of storage. The presence of this unidentified, failed research and development material in the same storage unit as approved GMP intermediates creates a risk of cross-contamination or mix-up between rejected materials and materials intended for use in drug product manufacturing.

  4. 4

    Facility ceilings not maintained in repair

    Buildings used in the manufacture, processing, packing, or holding of intermediates and API are not maintained in a good state of repair and kept in a clean condition. Specifically, Your firm has not maintained facility ceilings in critical GMP areas in a good state of repair. For example, during a facility walkthrough on 03/30/2026, it was observed that Room (b)(4), designated as "GMP Raw Material (Quarantine)," had damaged and discolored ceiling tiles above the sampling area. The ceiling tiles showed discolored stain marks and a crack approximately two feet long. Your QA staff observed a water leak in this room on 02/20/2026 but continued to use this room without repair. Room (b)(4) is used for the storage and sampling of GMP raw materials.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.