Skip to content

ChemPacific Corporation

6200 Seaforth St, Baltimore, Maryland, United States

FEI 3003299802DUNS 947763298

Company: ChemPacific Corporation · Linked by exact D-U-N-S match (947763298) in FDA registration data

FDA has 7 inspections on file for ChemPacific Corporation in Baltimore, Maryland (FEI 3003299802), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Oct 14, 2010. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, ChemPacific Corporation (D-U-N-S 947763298), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2010–2026
2 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
1 of 7
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jun 15, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate quality and data integrity controls

      The firm failed to maintain adequate quality control systems, including data integrity controls and procedural oversight, Specifically, a. Your firm failed to ensure that laboratory records include complete data derived from all tests conducted on GMP materials and failed to maintain adequate documentation of laboratory testing activities. Review of HPLC sample injection testing data from instruments (b)(4) and (b)(4) (software: (b)(4)) revealed that analysts performed 35 undocumented HPLC sample injections on GMP materials under the non-GMP testing project name "test" and the GMP testing project name (b)(4) between April 2023 and December 2024. Both instruments are used for testing GMP and non-GMP samples. This practice is also performed on the firm's other laboratory equipment: GC, IR/UV, and (b)(4). For example, analysts conducted sample testing without recording the activities in laboratory logbooks and analyst notebooks. The undocumented analyses fall into the following categories with the reasoning behind each injection: [illegible table - claimed purpose, material, injections, date, category including system suitability, condition check, analysis, testing, column check entries dated 04/23/2023, 04/27/2023, 08/16/2023, 08/28/2023, 06/13/2024, 12/18/2024]. Your firm's laboratory practices demonstrate a failure to maintain complete and accurate documentation of analytical testing performed on GMP materials. b. Your firm failed to establish adequate written procedures and controls for chromatographic peak (b)(4) integration used in assay and impurity testing of drug products, including intermediates and final API testing of (b)(4). Specifically, the firm lacks written procedures that establish limitations and criteria for peak area selection during manual integration of chromatographic data. For example, analysts perform manual integration for intermediates, final API assay, and impurity testing without documented procedures governing when and how manual integration should be applied. As a result, manual integration practices may vary among analysts due to the absence of standardized procedures and controls. The lack of standardized procedures for chromatographic peak integration creates significant risks to data integrity and product quality. c. Batch production and control records are not prepared at the time each action is taken, and entries are not signed in a timely fashion. On 03/30/2026, during the walkthrough of Room (b)(4) where Stage (b)(4) production of the intermediate (b)(4) lot (b)(4) (sub lot (b)(4)) being performed, it was observed that data was entered and signed by the operator in the batch record; however, the checker signature field was left blank. The chemist conducting the production stated that he "signs as the operator and that the checker will usually sign later because they trust each other." This demonstrates systemic documentation issues in which: 1) Batch record entries are not being signed at the time the action is performed or verified; 2) The independent verification system is not functioning as designed; and 3) Batch records do not provide contemporaneous documentation of manufacturing operations.

    2. Observation 2

      No ongoing API stability testing program

      The firm failed to have an ongoing testing program designed to monitor the stability characteristics of active pharmaceutical ingredients. Specifically, Your firm has not performed an ongoing stability testing program that is established to monitor the stability characteristics of API (b)(4) to establish or verify retest dates. For example: Your firm manufactured (b)(4) batches of API in (b)(4) (batches (b)(4)). Although these batches have been tested and approved for release, they have not been placed on stability studies.

    Show observations 3 to 4
    1. Observation 3

      Improper material storage and segregation controls

      Materials are not handled and stored in a manner to prevent contamination and ensure proper identification. Additionally, there is inadequate separation between materials of different statuses. Specifically, Your firm does not have material log-in records for your refrigerators and freezers used to store critical production materials. On March 30, 2026, during a facility walkthrough, it was observed that the firm stores intermediates in refrigerators and freezers (b)(4) but could not demonstrate adequate knowledge of the materials stored in specific units. For example, an unidentified bag of failed research and development intermediate IM-(b)(4) was found in Freezer (b)(4), which is also used to store GMP intermediates for (b)(4) production. The firm was unable to explain the reason for storing this material in the freezer or the duration of storage. The presence of this unidentified, failed research and development material in the same storage unit as approved GMP intermediates creates a risk of cross-contamination or mix-up between rejected materials and materials intended for use in drug product manufacturing.

    2. Observation 4

      Facility ceilings not maintained in repair

      Buildings used in the manufacture, processing, packing, or holding of intermediates and API are not maintained in a good state of repair and kept in a clean condition. Specifically, Your firm has not maintained facility ceilings in critical GMP areas in a good state of repair. For example, during a facility walkthrough on 03/30/2026, it was observed that Room (b)(4), designated as "GMP Raw Material (Quarantine)," had damaged and discolored ceiling tiles above the sampling area. The ceiling tiles showed discolored stain marks and a crack approximately two feet long. Your QA staff observed a water leak in this room on 02/20/2026 but continued to use this room without repair. Room (b)(4) is used for the storage and sampling of GMP raw materials.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jun 15, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 7, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 15, 2026FDA-FOIA-2026-5795Form 483· 1 of 4 sitesRecords released
  • Inspection ending Feb 15, 2024VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. May 3, 2024FDA-FOIA-2024-4074Form 483· 1 of 2 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
ChemPacific CorporationD-U-N-S 947763298

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names ChemPacific Corporation (D-U-N-S 947763298) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003299802 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003299802. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.