Skip to content

Nice-Pak Products, LLC Form 483, April 2026

FDA issued this Form 483 to Nice-Pak Products, LLC in Mooresville, Indiana (FEI 1822410) at the end of a drug inspection that ended April 20, 2026. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 23, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 20, 2026
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 23, 2026
186 days after the inspection
Facility
FEI 1822410
Mooresville, Indiana

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    No cleaning validation for shared equipment

    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, You manufacture multiple non-sterile OTC drug products and cosmetic products on non-dedicated equipment, including manufacturing Lines and However, cleaning validation studies have not been performed for this shared equipment to demonstrate your cleaning procedures are effective in removing residues and preventing cross-contamination.

  2. 2

    Deficient microbial monitoring omits tank surfaces

    Written procedures, designed to prevent objectionable microorganisms in drug products not required to be sterile, are deficient. Specifically, Your environmental monitoring program, governed by SOP QAS-094, "Microbial Environmental Monitoring," Rev. 6, is inadequate as it omits sampling of critical product-contact surfaces. Your firm does not perform microbial sampling of the internal surfaces of drug product mixing and storage tanks These product-contact surfaces, where the drug product is held for extended periods, represent a potential source for microbial contamination of the finished product. The exclusion of this equipment from your environmental monitoring program means you have no data to demonstrate that your processing equipment is maintained in a state of microbial control.

  3. 3

    Damaged moldy ceiling tiles above production

    Buildings used in the manufacturing of a drug product are not maintained in a good state of repair. Specifically, Ceiling tiles located directly above active manufacturing equipment and the production line were observed to be damaged, missing, and visibly contaminated. Numerous tiles exhibited water stains, dirt, and large, dark patches consistent in appearance with mold, creating a direct risk of contamination to exposed drug products and product-contact surfaces.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.