Adimmune Corporation
No. 3 Tanxing Rd., Sec. 1, Tanzi Dist., Taichung City, Taiwan
FEI 3008919998DUNS 657667952
FDA has 3 inspections on file for Adimmune Corporation in Taichung City, Taiwan (FEI 3008919998), from 2018 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is ADIMMUNE CORPORATION (D-U-N-S 657667952).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2018–2026
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Aug 15, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to follow mix-up prevention procedures
Your firm failed to follow written procedures designed to prevent mix-up of drug products, specifically: During the inspection of the product (b) (4) conducted on March 27, 2026, it was observed, in (b) (4) Building (b) (4), final fill and finish (b) (4) of drug products displaying (b) (4) labels were stored in the (b) (4) area instead of the designated (b) (4) area as required by established procedures [SOP (b) (4) (b) (4) 010 Procedure of (b) (4) Management].
- Observation 2
No validation of supplier test results
Your firm failed to establish the reliability of supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, (b) (4) and (b) (4) utilized for drug product overlay have not been conducted to validate supplier analyses.
Show observations 3 to 4
- Observation 3
Inadequate preventive maintenance procedures and documentation
Your firm failed to establish, follow and document preventive maintenance procedures, specifically, a. There is no documentation to support the replacement of (b) (4) utilized at the (b) (4) supply source for drug product overlay after (b) (4) uses according to Standard Operating Procedure (SOP) (b) (4) 140: BLD (b) (4) Filling & Packaging Line (b) (4) The Standard of Integrity Test in BLD (b) (4) Filling & Packaging Plant Line (b) (4), effective 04/23/24. b. Procedures have not been established as part of the (b) (4) preventative maintenance protocol to ensure the (b) (4) system is maintained in a good state of repair. (b) (4) accumulation was found (b) (4) (b) (4) of the facility (b) (4) system (b) (4). Additionally, deterioration of the (b) (4) on (b) (4) was observed.
- Observation 4
Aseptic procedures not followed or inadequate
Written operating procedures are not followed or are inadequate, specifically, a. On March 30, 2026, during observation of the Formulation process, we observed staff not regularly sanitizing their gloves as per procedure. Specifically, we observed the (b) (4) main manufacturing staff working (b) (4) laminar flow hood (b) (4) the hood without sanitizing. Section 7.3.3 of SOP (b) (4)S067 Good Aseptic Operation Practice states: "Sterile gloves should be (b) (4) sanitized or changed (b) (4) (b) (4) aseptic operation." b. SOP (b) (4)S067 Good Aseptic Operation Practice does not clearly define the frequency of glove sanitization for manufacturing staff i.e. (b) (4) a laminar flow hood. c. During observation of the Formulation process on March 30, 2026, manufacturing staff was seen placing a (b) (4) on the laminar flow hood labeling it as (b) (4) processing. No cleaning of the laminar flow (b) (4) was observed (b) (4). Section 7.6.1 Per SOP (b) (4) 285 states: Cleaning of the (b) (4) (b) (4) each (b) (4), the (b) (4) must be wiped and disinfected with a (b) (4) containing (b) (4)." d. On March 31, 2026, during observation of the Filling operation on Line (b) (4) a deviation from established aseptic practices was noted when manufacturing personnel performed troubleshooting activities. Specifically, gowned operators were observed making direct contact with the (b) (4) using (b) (4) and allowing their (b) (4) (b) (4) to contact the (b) (4) surface while wearing cleanroom personal protective equipment (PPE). This practice is not consistent with the facility's SOP (b) (4)067, Section 7.2 Item 2, which states: '(b) (4) (b) (4) gowning (b) (4)." e. Additionally, during observation of the Filling process on March 31, 2026, aseptic processing personnel / maintenance staff were observed repeatedly contacting the (b) (4) with their (b) (4) after those same (b) (4) had contacted the (b) (4) surface.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Aug 15, 2026. Each one asked for a Form 483.
Inspection ending Apr 2, 2026VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 15, 2026FDA-FOIA-2026-7904Form 483· 1 of 3 sitesRecords released
- Jun 9, 2026FDA-FOIA-2026-5646Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- ADIMMUNE CORPORATIOND-U-N-S 657667952
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008919998 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008919998. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.