Skip to content

Jiangsu Hansoh Pharmaceutical Group Co Ltd.

Economic & Technical, 5 Dongjin Road; Dev. Zone, Lianyungang, China

FEI 3008316144DUNS 421304996

Company: Jiangsu Hansoh Pharmaceutical Group Co., Ltd. · Linked by exact D-U-N-S match (547876677) in FDA registration data

FDA has 2 inspections on file for Jiangsu Hansoh Pharmaceutical Group Co Ltd. in Lianyungang, China (FEI 3008316144), from 2019 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. Two of the five FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2026. Its registrant, Jiangsu Hansoh Pharmaceutical Group Co., Ltd. (D-U-N-S 547876677), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2019–2026
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
5 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate sterilization and smoke study validation

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process. Specifically, A. Scientific evidence could not be provided demonstrating the source of the smoke used during your air flow visualization studies is neutrally buoyant. During your review of smoke study videos in your aseptic filling lines in workshops (b) (4) as well as the (b) (4) line, the following discrepancies were noted: 1. The positioning of the (b) (4) ducts of the (b) (4) RABS in relation to the grade B area has the potential to short circuit the grade B air flow, causing an upward movement of air in the cleanroom. Smoke studies have not been performed in this area to demonstrate adequate airflow in aseptic filling lines workshops (b) (4) 2. Air flow videos are recorded with the smoke pointing directly upwards, not providing a uniform curtain of smoke in which to evaluate air currents. 3. Turbulence was noted in various smoke study videos which were not assessed or addressed during the firm's review and approval. 4. Smoke is not present where activities are taking place. Additionally, rapid dissipation of smoke was noted which reduces the ability to detect eddy currents and adverse airflow. 5. When the RABS (b) (4) is (b) (4), first air does not reach the product contact surfaces. B. Media fills are not representative of commercial manufacturing. Only the duration of an intervention is simulated in a media fill and not the physical activities. For example, C-VP-206-026000-2541 Validation Protocol of Media Fill for (b) (4) ml vial in workshop (b) (4) requires a (b) (4) simulation of maintenance in the filling line. On 17Oct2025, the maintenance personnel performed an activity inside the RABS for approximately (b) (4) then remained standing (b) (4) the RABS with the (b) (4) for the remaining (b) (4) The operator did not perform any additional activities during this time and was considered qualified by this media fill. C. Your firm's (b) (4) decontamination validation for aseptic processing areas has not been adequately validated to demonstrate effective sterilization of all critical surfaces. 1. Deficient (b) (4) design • Workshop (b) (4) were observed, (b) (4) (b) (4) Thus creating areas of occlusion not fully exposed to (b) (4) • Workshops (b) (4) do not (b) (4) observed were not (b) (4) Additionally, (b) (4) were not (b) (4) during (b) (4) process. • You have not evaluated the (b) (4) efficacy in (b) (4) areas of the (b) (4) 2. Inadequate (b) (4) sterilization assurance • (b) (4) are (b) (4), prior to initial installation • There is no assurance that (b) (4) are completely and uniformly covered by the (b) (4) during routine decontamination cycles 3. Incomplete validation documentation • There is no list of equipment that remains in the room during (b) (4) cycle, in the validation protocol or in the report • There is no documentation on specific locations of BI and chemical indicators placement within the validation protocol and report US marketed products manufactured in Workshop (b) (4) include (b) (4) (b) (4) D. There are no defined inherent or corrective interventions to be performed during a media fill in order to be qualified as an aseptic filling operator. For example, (b) (4) operators are documented as performing setup during commercial manufacturing. One operator performs the setup of the equipment, including aseptic connections, while the remaining operators assist by passing equipment to the main operator. In the batch record, there is no differentiation between the main operator and the support operators. Media fills are handled the same way with no way to determine who the support operators were verses who performed the aseptic connection. This results in no assurance that an operator performing setup in commercial manufacturing previously performed a successful setup in a media fill. E. The sterilization processes used for equipment that

      Shortened here; the PDF has the full text.

    2. Observation 2

      Failure to investigate discrepancies and complaints

      Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications whether or not the batch has already been distributed. A. Reoccurring gram-negative recoveries in the grade B area surrounding the injectable manufacturing lines do not get investigated to determine the source. In 2025, the following gram-negative occurrences were reported: Year Workshop Occurrences (b) (4) Microbial name [illegible] Year Workshop Occurrences (b) (4) Microbial name [illegible] Year Workshop Occurrences (b) (4) Microbial name [illegible] B. Inadequate investigation into the (b) (4) reading. While observing filling of batch (b) (4) of (b) (4) Injection, USP, on 20Apr2026, I observed the (b) (4) governing the (b) (4) RABS to be (b) (4) at approximately 12:40pm, and took a photo of the (b) (4) I inquired about the status of the (b) (4) after 1:00pm. The firm initiated an investigation which determined the tube was cracked in the (b) RABS which is connected to the (b) (4) The investigation stated the reading of the (b) (4) was within tolerance at 1:24pm (qualified range (b) (4) When I stated I observed the (b) (4) to be (b) (4) at 12:40pm, management stated this could be due to fluctuation. There was no evaluation as to whether a (b) (4) would fluctuate with a cracked tube. The investigation did not address the discrepancy in the acceptable reading at 1:24pm. C. Your firm's complaint investigations lack adequate depth and rigor as noted in the following deficiencies: 1. Investigations do not include a thorough evaluation of all possible factors in the manufacturing process that could have contributed to the complaint or defect. For example, complaint CP2500013, involving (b) (4) Injection USP, for loose caps, and leaking vials, failed to investigate capping speed. 2. Investigations fail to include examination and testing of retain samples when applicable to determine if the complaint represents a broader quality issue. For example, retain samples were not inspected during the investigations of the following complaints, CP2500039 involving (b) (4) Injection, CP250035 involving (b) (4) Injection, CP250001 involving (b) (4) Injection, and CP2500030 involving (b) (4) Injection, USP. 3. Quality does not perform an equipment and process review, but instead relies on Production to conduct their own review. Logs and raw data are consistently not reviewed to identify potential process deviations or equipment malfunctions. Quality defers production equipment and log review to the production department, and did not review raw data in complaint investigations CP2500039 involving (b) (4) Injection, CP250035 involving (b) (4) Injection, and CP250001 involving (b) (4) Injection. 4. Your firm did not perform a retrospective review for similar possibilities during the investigation of complaint CPC240024, involving a (b) (4) packaging artwork error of (b) (4) Injection, USP, with the incorrect (b) (4) instructions. Additionally, the CAPA did not adequately address the root cause.

    Show observations 3 to 7
    1. Observation 3

      Missing aseptic and visual inspection procedures

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. A. Inadequate aseptic technique was observed in the review of videos and while watching the aseptic filling of (b) (4) Injection in workshop (b) (4) on 20Apr2026. Discrepancies include: 1. Operators block first air during the addition of stoppers. This was seen in workshops (b) (4) (b) (4) aseptic filling lines. 2. An operator was seen having to lean his upper body inside the RABS unit to retrieve and return forceps in workshop (b) (4) 3. Reaching over (b) (4) vials during the execution of an intervention. The affected vials were not removed. B. The firm's visual inspection qualification program is inadequate to demonstrate that inspectors can reliably detect all defect types in sterile injectable products. 1. Your visual inspection qualification program lacks adequate Quality Unit over-site and control. Production personnel maintain qualification kits, administer qualification tests, make pass/fail determination with only a Quality review of the bottle condition. This arrangement fails to ensure the proper administration of qualification tests according to a written procedure as well as fails to ensure objective evaluation of inspector performance. 2. Your firm's (b) (4) mL liquid visual inspection qualification kit lacks documented verification of the actual particle sizes present in the qualification vials. For example, vial (b) (4) is labeled as containing a (b) (4) particle of (b) (4) um, but visual observation indicated the particle is significantly larger. Your firm has not provided microscopic measurements, or objective evidence confirming the actual size of particles in any qualification vial. Inspectors can not be properly assessed on their ability to detect particles at specified size limits when the actual particle sizes are unknown. 3. Your firm's (b) (4) visual inspection qualification kit, (b) (4) mL, is inadequate because it does not include representative range of foreign particulate matter types and sizes that could reasonably occur during manufacturing operations. The kit only contains (b) (4) um fiber for (b) (4) products, which fails to challenge the inspector's ability to detect other common defects, such as glass particles, or fibers, of varying sizes and colors. 4. The (b) (4) mL liquid visual inspection qualification kit does not contain turbid samples, white spots/particles, or colored particles. 5. Your (b) (4) visual inspection qualification program uses only (b) (4) mL vials for inspector qualification, while your commercial production includes vial sizes ranging from (b) (4) mL to (b) (4) mL. This single-size approach fails to adequately qualify inspectors to detect defects across the range of container sizes and fill volumes used in production, as detection difficulty varies with container geometry, fill volume, and viewing angles. 6. Complaint photos depicting particulate matter are not incorporated into training or qualification kits, preventing inspectors from learning to recognize real world defects 7. A (b) (4) item qualification kit is made prior to qualify personnel performing visual inspection in the laboratory (release testing). The (b) (4) foreign object defects in this kit are randomly selected from other defect kits, resulting in a qualification kit containing liquid vials of different sizes (b) (4) (b) (4) This kit is not reflective of how product is tested in the laboratory during release. Additional deficiencies include: • The qualification kit always contains (b) (4) defects. • After documenting the status of the container being inspected, the analyst peels off the sticker revealing the original vial number and documents that number on the form. All good vials are identified with a prefix of (b) (4) • When the proctor confirms the correct identification of the defect is not documented. C. Interventions are not trended based on the location of where the interv

      Shortened here; the PDF has the full text.

    2. Observation 4

      Deficient environmental monitoring system

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, the following discrepancies were noted during review of the environmental monitoring program: A. Not all (b) (4) used during aseptic filling of injectable products are sampled at the end of the batch. C-VP-206-71000-2617 Risk Assessment of Environmental Control in Workshop (b) (4) specifies sampling of (b) (4) to monitor after batch manufacturing. This results in (b) (4) being monitored (b) (4) This assessment was not based on an evaluation of where interventions take place. Similar risk assessments resulted in (b) (4) in (b) (4) regardless of whether they were used during aseptic filling. B. Due to space constraints, no environmental monitoring (non-viable particles, viable air, settle plates) is performed where (b) (4) stopper addition takes place. Only particle counting is executed in the (b) (4) hood (b) (4) area where operator passes (b) (4) stopper bags to stopper bowl areas). No activities are performed in this area during monitoring.

    3. Observation 5

      Inadequate cleaning and disinfection system

      Your firm failed to establish an adequate system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Discrepancies were noted during the cleaning performed on 20Apr2026 in workshop (b) (4) after the manufacture of (b) (4) Injection-USP including: A. Operators were seen kneeling on the (b) (4) as well as reaching over and leaning on equipment during cleaning. B. Using the same cloth to clean numerous pieces of equipment, including cleaning the lower parts of the (b) (4) RABS followed by cleaning the inside of (b) (4) RABS (b) (4) C. Only the forceps used during setup or the removal of a stuck stopper are (b) (4) All remaining forceps, including those used in the removal of (b) (4) fallen/jammed vials are not (b) (4) These forceps remain on the aseptic filling lines indefinitely. These forceps are not documented as being present during the (b) (4) cycle. This accounts for (b) forceps inside the grade A area in workshop (b) (4) line. (b) (4) D. There is no data in support of spraying of the (b) (4) RABS (b) (4) with (b) (4) prior to (b) (4) disinfects the entire surface of the (b) (4) Review of media fill videos showed an operator using as few as (b) squirts to disinfect a RABS (b) (4) (4)

    4. Observation 6

      No calibration program for weight checks

      Routine calibration, inspection, checking of automatic, mechanical, electronic equipment is not performed according to a written program designed to assure proper performance. The following discrepancies were noted during the review of the (b) (4) weight check systems on aseptic filling lines in workshops (b) (4) A. Workshop (b) (4) The weight checks performed on the (b) (4) balances prior to use, do not bracket the amount being weighed. The balances are verified using a (b) (4) weight while the approximate mass of the items being weighed is approximately (b) (4) and (b) g (empty and filled vial). No manual (4) weight checks are performed throughout filling. This system is used in the aseptic filling (b) (4) Injection. B. The ability of the system to reject over filled and under filled vials is not confirmed prior to start of manufacturing. The vials used during the functionality check, performed (b) (4) are not weighed out to confirm rejects near the upper and lower weight limits. The Validation Manager confirmed the low weight vials are made by (b) (4) (b) (4) and that they (b) (4) to the designated overfill vial so the vials are obviously over and under filled during the functionality check performed in workshops (b) (4) and (b) (4) This affects (b) (4) Injection (b) (4) and (b) mg/vial and (b) (4) Injection, USP (b) (4) C. Although required by procedure, no (b) (4) checks have been performed on the (b) (4) balances used to perform (b) (4) weight checks in the (b) (4) workshop. No manual weight checks are performed during manufacturing.

    5. Observation 7

      Missing in-process control procedures

      Control procedures are not established that describe in process controls which validate the performance of those manufacturing processes that may be responsible for causing variably in the characteristics of in-process materials and the drug product. A. Your firm failed to validate the in-process inspection method to evaluate (b) (4) of aseptically (b) (4) Injection. (b) (4) (b) (4) • Currently you use (b) (4) but provided no documented evidence that this method has been validated for accuracy, precision, or reproducibility. • There is no documented acceptance criteria for (b) (4) • There is no documented training program for personnel performing (b) (4) inspections, including no visual training aids or competency assessments to ensure consistent (b) (4) technique. B. The method used to test the sterility of (b) (4) used during (b) (4) interventions, P-QS-MA-900017-A01 Operating Procedure for Inspection of (b) (4) has not been validated. C. Reconciliation of injections is not performed on the chromatograms generated using OpenLab 2.4 software.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Apr 24, 2026OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Aug 12, 2026FDA-FOIA-2026-7750Form 483· 1 of 3 sitesRecords released
    2. Jun 2, 2026FDA-FOIA-2026-5481Form 483Records released
  • Inspection ending Dec 16, 2016

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-5061Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. Aug 5, 2026FDA-FOIA-2026-7576Form 483 + EIRClosed
    2. Apr 1, 2022FDA-FOIA-2022-2369Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, sterilization
Registration runs through
Dec 31, 2026
Registrant
Jiangsu Hansoh Pharmaceutical Group Co., Ltd.D-U-N-S 547876677

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Jiangsu Hansoh Pharmaceutical Group Co., Ltd. (D-U-N-S 547876677) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3008316144 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3008316144. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.