Bausch and Lomb Incorporated

8500 Hidden River Pkwy, Tampa, Florida, United States

FEI 1000113778DUNS 079587625

FDA has 11 inspections on file for Bausch and Lomb Incorporated in Tampa, Florida (FEI 1000113778), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated. FDA has issued 3 warning letters under this FEI, the latest on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's 483.

1 import refusal is filed under this FEI, on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Bausch & Lomb Incorporated (D-U-N-S 079587625).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
11, 2009–2026
2 OAI · 2 VAI · 7 NAI
Inspections with 483 observations shown
5 of 11
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest FY2023
Warning letters
· CDER ↗
3 on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate adverse event complaint investigations

      OBSERVATION 1 Complaint records are deficient in that they do not include the findings of the investigation and follow-up. Specifically, A. Your firm failed to adequately investigate customer complaints that were received as Adverse Events. The following adverse events were reviewed and deemed inadequate; this is not an exhaustive listing: i. Complaint# 1406005 opened on 08/03/2025 as an Adverse Event and critical complaint. Customer found a shard of metal in the ointment that was on their ®®. The product was (b) (4) (b) (4) Ointment ®@), Lot# (b) (4) Expiration (b) (4). ii. Complaint# 1285238 opened on 12/20/2023 as an Adverse Event. Customer stated they immediately felt a burning, intense itching, and what felt like "shards of glass," resulting in their ©® becoming (b) (4). This product was (b) (4) (b) (4) Solution USP (8)(@), Lot# (b) (4). Expiration (b) 4). iii. Complaint# 1269630 opened on 11/15/2023 as an Adverse Event. Customer had a severe reaction to the (0) 4) utilized. The product was (b) (4) (b) (4). Lot# (b) (4) Manufacturer Lot# (b) (4). Expiration (0) 4). B. Additionally, your firm failed to file a Field Alert Report (FAR) for Complaint# 1329875 opened on 08/07/2024 as an Adverse Event (AE). Customer stated they noticed a "black" substance inside the (b) (4) and on the inside of the cap. The product was (b) (4) Lot# (b) (4), Expiration (6)(@). The firm reviewed, evaluated and tested the black substance internally and isolated Pseudomonas aeruginosa. However, your firm failed to characterize the black foreign matter that was in the cap and/or of the container. The following complaints were observed in relation to the complaints related to black foreign substances, include but are not limited to: (b) (@) "small black ball of matter dispense from the bottle" 1377182 Foreign Matter 1361398 "black oily substance on the tubes and the tubes appear to have a fuzzy substance on the tubes" Consistency/Viscosity / Counterfeit Product [illegible] "black [illegible] inside the cap and on the [illegible]" Foreign Matter 1426384, 1436734 "blackish spots that appear to be mildew or something similar" Foreign Matter

    2. Observation 2

      Inadequate aseptic and environmental controls

      OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. Your operators are not following appropriate aseptic practices during active manufacturing activities. The following is not an exhaustive listing of the inadequate aseptic practices observed during the commercial manufacturing of (b) (4) Solution (b) (4) (Lot# (b) (4)) on Filling Line#: i. Brisk movements and walking swiftly throughout the Grade B room near the (b) (4) Filling Line (Grade A). ii. Donning a ®® pair of sterile gloves and moving away from the glove donning station. We also observed some instances where they put on one glove and held the second one as they walked away from the station and utilizing the sterile ®® pair to throw away trash. iii. While changing the environmental monitoring plates within the Grade A area of Filling Line# B the operator was seen moving quickly and reaching over areas where open and exposed empty bottles were located. iv. During an intervention of removing a stuck empty bottle, we observed the operator manipulate the forceps at the end that comes in contact with the open container. Additionally, the operator abruptly manipulated a jammed bottle in a manner that the bottle was flicked into the (b) (4) sterile bowl. v. Operator inadequately entered the (b) (4) to perform interventions. Horizontal (b) (4) donning was performed rather than a slow vertical donning to prevent reaching over open and exposed bottles to prevent airflow disruption. vi. Operators were observed placing components (plastic bottles, (b) (4) caps, and (b) (4) tips), directly touching the inside of the hopper and at times (b) (4) were thrown inside the hopper and (b) (4) pulled out of the hopper with tweezers. This is contrary to your procedure WI80-004A revision 5, effective, titled "Approved Methodology for Performing Aseptic Interventions on Filling Lines" which states in section 7.1 "7.1.5. Aseptically pour the components into the hopper paying close attention not to let the component ®® touch the inside of the hopper. Do not shake the ® over the open hopper to remove all of the components." B. Your firm failed to adequately investigate bacterial and mold contamination in your Grade A and B aseptic areas and Personnel Garment monitoring. Review of your Laboratory Information Management System ((B) (4)) report of organisms recovered from 2023 through present, revealed 223 Nonconformances (NCs) were initiated due to microbial contamination of garment personnel and 24 NCs were initiated due to mold contamination. In the Aseptic Grade A and B areas there were a total of 255 NCs (Grade A = 163 and Grade B = 92) initiated for microbial contamination and 24 NCs initiated due to mold contamination. Recoveries revealed the following mold and gram-negative and positive bacterial species that include but are not limited to: Pseudomonas spp., Burkholderia spp., Staphylococcus spp., Aspergillus spp., Penicillium spp., Fusarium spp., Cladosporium spp., Trichophyton spp., and Curvularia spp. In addition, Burkholderia Group was found on personnel monitoring garment points on three separate occasions in 2024. Furthermore, your firm has also isolated Burkholderia spp. in the Aseptic Compounding Rooms (b) (4) on the floor near (b) (4) (sample site (b) (4)1) and during your Cleaning Validation C630-H-00; PARTS WASHER in the rinse solution at the (b) (4). C. Your firm failed to identify gram negative environmental isolates from (b) (4) and (b) (4) systems even when action and alert limits are exceeded. The exceeded alert and action limit isolates are only characterized as "Absence Indicator Organisms." Between 2024 and 2026 there were 21 GNR (Gram Negative) isolates either exceeding alert or action limits that were not identified and only characterized as "Absence Indicator Organisms." D. Your firm failed to review the integrity of environmental monitoring (EM)

      Shortened here; the PDF has the full text.

    Show observation 3
    1. Observation 3

      Failure to follow receiving and storage procedures

      OBSERVATION 3 Written procedures are not followed for the receipt, storage and handling of. Specifically, A. Your firm failed to document and complete the Purchasing Notification of Missing Documents Form (SOP21-076 Form B) in your locked Quarantined cage for the following incoming shipments: i. (b) (4) (Material (b) (4)), Lot (b) (4) received on 16-FEB-2026 ii. (b) (4) (Material# (b) (4)) received on 11-MAR-2026 iii. (b) (4) materials (Lot# (b) (4)) received on 11-MAR-2026 These items have not been issued the SOP21-076 Form B. This issue was not resolved within the required time or escalated to the Warehouse and Quality Management Team as required by SOP21-076, Receiving Process, Rev. 32, Effective Date: 24-NOV-2025 section 5.5.1. which states, "If the shipment is missing the proper documentation or is incorrect or incomplete, immediately email the Sourcing and Procurement, Materials Management and Incoming Quality departments a complete copy of SOP21-076 Form B (Purchasing Notification of Missing Documents). If the issue is not resolved within (b) (4) escalate the issue to the Warehouse and Quality Management team." Your Quality Assurance Manager stated that Form B has not been filled out for all materials missing documents upon receipt and the procedure has not been followed. B. Your firm failed to place materials in the specified locations in your (b) (4) Storage (2-8°C) area as assigned in your inventory management system (b) (4) for the following products: i. Material (b) (4) Lot (b) (4) with Location (b) (4) was found in Location# (b) (4). ii. Material (b) (4) Lot (b) (4) with Location (b) (4) was found in Location# (b) (4). There is no assurance that materials received have been placed in the correct location as assigned in your inventory system to prevent product mix-ups.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.

    2. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    3. Deviations from laboratory control requirements

      Deviations from written test procedures are not justified.

    4. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. NAINo objectionable conditions that need follow-upDrugs · Postmarket Surv. and Epidemiology4 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigations of particle excursions

      QUALITY SYSTEM OBSERVATION 1 Written records of investigations into unexplained discrepancies do not include adequate evaluation, conclusions, and follow-up. The following investigations pertain to non-viable particles exceeding action limits at multiple locations on Aseptic Filling Lines (Lines I and II) during a [illegible] (through the start of this inspection). These lines are used in the manufacture of sterile drug products manufactured at your facility such as Latanoprost Ophthalmic Solution (0.005%), Opcon-A, Ketotifen Fumarate Ophthalmic Solution (0.025%), and Tobramycin [illegible]. A. Specifically, 20 out of 20 Nonconformance Reports (NCRs) reviewed as well as their associated Root Cause/CAPA Investigation Reports were inadequate based on the following: 1. Investigations are not complete and potential root causes are not always identified and justified. For example, NCRs #474179, 473135 [illegible] non-viable particle counts were attributed to the bottle - without scientific justification. Review revealed that as part of the investigation a sample [illegible]. Review of the laboratory report [illegible]. 2. There was no scientific justification in the investigations for non-viable particle sampling method/technique and/or the sampling equipment as the root cause; however there was no scientific [illegible] that the sampling techniques or equipment that was used caused the particle reading. For example, NCR #524351 states that an [illegible] caused the out of specification non-viable particle result and was attributed to a sampling error. However, no scientific rationale could be provided to justify the sampling error; since during this [illegible] continuous container movement during aseptic drug products. B. The investigation report submitted with [illegible] is not complete and does not document corrective action. Two submission stability batches (Lot #[illegible]) (bottle manufactured during bottle molding at the bottle manufacturer) were sufficient to maintain compliance with [illegible] required to further evaluate potential root causes and corrective actions to minimize their impact. At the time of inspection there was additional investigation underway to identify potential root causes; however it was in draft form. The RC/CAPA #408329 (opened on March [illegible]) documents stability failures for [illegible] and is still open and no effective corrective actions have been implemented to mitigate the risk of particulate contamination. According to RC/CAPA #408329, the particulates identified included flakes of [illegible] and the particulates identified were cellulose based polymer, and amorphous particulates from the bottle and tip for both the II bottle and [illegible] both the II bottle and [illegible] bottle is made [illegible]. The only difference is the [illegible] tip. There is no assurance that the [illegible] product will not also be impacted and that the particulates caused the stability failures of Lot #'s [illegible]. C. There was no investigation conducted into the failure of the microscopic particle count method for [illegible] submission stability batch (Lot #[illegible]) ([illegible] ml bottle [illegible] fill) failed particulate matter testing with the following results: • 54 particles/ml ≥10µm • 9 particles/ml ≥25µm • 3 particles/ml ≥50µm There was no investigation conducted into the failure to determine product impact or corrective action. D. The Nonconformance Investigation Report for [illegible] found leaking during the October 2015 shutdown [illegible] is inadequate. Specifically for Aseptic Fill [illegible] was identified with a potential impact was [illegible] issued for each of the (non-viable particle) locations (the leaking filters). No further actions are required at this time. The review of the non-viable particle testing for Aseptic Fill Line [illegible] revealed five action level excursions between [illegible] at the following locations that correspond to the locations i

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate environmental monitoring program

      FACILITIES AND EQUIPMENT SYSTEM OBSERVATION 2 Procedures designed to prevent microbiological contamination are not established, written and followed. A. Environmental sampling is not conducted per your SOP-72-001, section 6.5.2 that states [illegible]. Specifically, I observed equipment was not operating when the environmental samples were collected: • On 2/10/16, Aseptic Fill Line [illegible] Sulfates and Dexamethasone Ophthalmic [illegible] A (ISO 100) non-viable particle air sampling locations were collected while the equipment was in operation [illegible]. • On 2/10/16, Aseptic Fill Line [illegible] Sulfates and Dexamethasone Ophthalmic Suspension [illegible] A (ISO 100) non-viable particle air sampling locations were collected while the equipment was in operation [illegible]. • On 2/12/16, Aseptic Fill Line [illegible] 5 Class A (ISO 100) non-viable particle air sampling locations were collected while no equipment was in operation. B. The written environmental sampling program lacks justification for sampling locations. No documentation was provided to justify the locations of the new probe bracket holders installed on your Aseptic Fill Lines (e.g., I & II were selected as representative locations to monitor environmental conditions (e.g., non-viable particles)). In addition the use of these holders is not mentioned in current SOP-72-001, rev 65, which dictates your environmental monitoring program. For example, the location of Aseptic Fill Line I [illegible] does not match the sampling point that was used in the Performance Qualification of the Aseptic Fill Line [illegible]. No documentation or scientific rationale was provided for why this sampling point was changed from its original location. C. Smoke studies were inadequate to demonstrate unidirectional airflow and sweep over and away from the critical processing areas of the ophthalmic filling area. For example, smoke studies have not been conducted after room and equipment changes have occurred to show that the changes have not adversely affected the room's unidirectional airflow (e.g., Class A curtain layout changes performed [illegible]). D. There is no assurance that your firm’s routine environmental monitoring during aseptic filling is reliable. For routine monitoring used for manufacturing [illegible], the firm uses [illegible] sample at each sampling location. Currently your firm only uses the continuous monitoring system during manufacturing for products manufactured for markets. There is no justification or data to support that the current sampling frequency is superior to continuous non-continuous monitoring or to support changes that might compromise the facility during process changes.

    Show observations 3 to 4
    1. Observation 3

      Unvalidated hold times for utensils/valves

      OBSERVATION 3 Equipment and utensils were not maintained at appropriate intervals to prevent alteration of the safety, identity, strength, quality or purity of the drug product. Specifically, your firm has not validated appropriate hold times that ensure utensils that are used in aseptic fill lines are free of contamination and valves that come in direct product contact during the manufacture of sterile drug products on aseptic filling lines at your facility.

    2. Observation 4

      Missing in-process control procedures

      PRODUCTION SYSTEM OBSERVATION 4 Control procedures are not established which monitor the output of those manufacturing steps which may be responsible for causing variability in the characteristics of in-process material and the drug product.

  8. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

  10. NAINo objectionable conditions that need follow-upDrugs · Bioresearch Monitoring1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing each significant step in the operation, for each batch of drug product produced.

  11. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  12. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Mar 20, 2026OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. May 11, 2026FDA-FOIA-2026-4853Form 483· 1 of 5 sitesRecords released
  • Inspection ending Aug 25, 2023NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 1, 2024FDA-FOIA-2024-9689EIRWithdrawn
  • Inspection date not given

    3 requests. FDA released records in answer to a request for its Form 483 on Sep 30, 2026. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2023-403EIRClosed
    2. Sep 18, 2026FDA-FOIA-2026-9092Inspection recordsDirected Requester to Publicly Available Information
    3. Sep 16, 2026FDA-FOIA-2026-8966Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 6 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 11 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000113778, one row per refused product line.

1 refusal on 2025-12-22 · charged UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2025-12-22

    WATER, PURIFIED (EYEWASH)65FAK06

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-8693724-3/10001/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Bausch & Lomb IncorporatedD-U-N-S 079587625

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000113778 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000113778. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.