Skip to content

Bausch and Lomb Incorporated Form 483, March 2026

FDA issued this Form 483 to Bausch and Lomb Incorporated in Tampa, Florida (FEI 1000113778) at the end of a drug inspection that ran from March 12 to March 20, 2026. It lists 3 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on September 4, 2026.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 24, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Mar 12–20, 2026
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jul 24, 2026
126 days after the inspection
Facility
FEI 1000113778
Tampa, Florida

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate adverse event complaint investigations

    OBSERVATION 1 Complaint records are deficient in that they do not include the findings of the investigation and follow-up. Specifically, A. Your firm failed to adequately investigate customer complaints that were received as Adverse Events. The following adverse events were reviewed and deemed inadequate; this is not an exhaustive listing: i. Complaint# 1406005 opened on 08/03/2025 as an Adverse Event and critical complaint. Customer found a shard of metal in the ointment that was on their ®®. The product was (b) (4) (b) (4) Ointment ®@), Lot# (b) (4) Expiration (b) (4). ii. Complaint# 1285238 opened on 12/20/2023 as an Adverse Event. Customer stated they immediately felt a burning, intense itching, and what felt like "shards of glass," resulting in their ©® becoming (b) (4). This product was (b) (4) (b) (4) Solution USP (8)(@), Lot# (b) (4). Expiration (b) 4). iii. Complaint# 1269630 opened on 11/15/2023 as an Adverse Event. Customer had a severe reaction to the (0) 4) utilized. The product was (b) (4) (b) (4). Lot# (b) (4) Manufacturer Lot# (b) (4). Expiration (0) 4). B. Additionally, your firm failed to file a Field Alert Report (FAR) for Complaint# 1329875 opened on 08/07/2024 as an Adverse Event (AE). Customer stated they noticed a "black" substance inside the (b) (4) and on the inside of the cap. The product was (b) (4) Lot# (b) (4), Expiration (6)(@). The firm reviewed, evaluated and tested the black substance internally and isolated Pseudomonas aeruginosa. However, your firm failed to characterize the black foreign matter that was in the cap and/or of the container. The following complaints were observed in relation to the complaints related to black foreign substances, include but are not limited to: (b) (@) "small black ball of matter dispense from the bottle" 1377182 Foreign Matter 1361398 "black oily substance on the tubes and the tubes appear to have a fuzzy substance on the tubes" Consistency/Viscosity / Counterfeit Product [illegible] "black [illegible] inside the cap and on the [illegible]" Foreign Matter 1426384, 1436734 "blackish spots that appear to be mildew or something similar" Foreign Matter

  2. 2

    Inadequate aseptic and environmental controls

    OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. Your operators are not following appropriate aseptic practices during active manufacturing activities. The following is not an exhaustive listing of the inadequate aseptic practices observed during the commercial manufacturing of (b) (4) Solution (b) (4) (Lot# (b) (4)) on Filling Line#: i. Brisk movements and walking swiftly throughout the Grade B room near the (b) (4) Filling Line (Grade A). ii. Donning a ®® pair of sterile gloves and moving away from the glove donning station. We also observed some instances where they put on one glove and held the second one as they walked away from the station and utilizing the sterile ®® pair to throw away trash. iii. While changing the environmental monitoring plates within the Grade A area of Filling Line# B the operator was seen moving quickly and reaching over areas where open and exposed empty bottles were located. iv. During an intervention of removing a stuck empty bottle, we observed the operator manipulate the forceps at the end that comes in contact with the open container. Additionally, the operator abruptly manipulated a jammed bottle in a manner that the bottle was flicked into the (b) (4) sterile bowl. v. Operator inadequately entered the (b) (4) to perform interventions. Horizontal (b) (4) donning was performed rather than a slow vertical donning to prevent reaching over open and exposed bottles to prevent airflow disruption. vi. Operators were observed placing components (plastic bottles, (b) (4) caps, and (b) (4) tips), directly touching the inside of the hopper and at times (b) (4) were thrown inside the hopper and (b) (4) pulled out of the hopper with tweezers. This is contrary to your procedure WI80-004A revision 5, effective, titled "Approved Methodology for Performing Aseptic Interventions on Filling Lines" which states in section 7.1 "7.1.5. Aseptically pour the components into the hopper paying close attention not to let the component ®® touch the inside of the hopper. Do not shake the ® over the open hopper to remove all of the components." B. Your firm failed to adequately investigate bacterial and mold contamination in your Grade A and B aseptic areas and Personnel Garment monitoring. Review of your Laboratory Information Management System ((B) (4)) report of organisms recovered from 2023 through present, revealed 223 Nonconformances (NCs) were initiated due to microbial contamination of garment personnel and 24 NCs were initiated due to mold contamination. In the Aseptic Grade A and B areas there were a total of 255 NCs (Grade A = 163 and Grade B = 92) initiated for microbial contamination and 24 NCs initiated due to mold contamination. Recoveries revealed the following mold and gram-negative and positive bacterial species that include but are not limited to: Pseudomonas spp., Burkholderia spp., Staphylococcus spp., Aspergillus spp., Penicillium spp., Fusarium spp., Cladosporium spp., Trichophyton spp., and Curvularia spp. In addition, Burkholderia Group was found on personnel monitoring garment points on three separate occasions in 2024. Furthermore, your firm has also isolated Burkholderia spp. in the Aseptic Compounding Rooms (b) (4) on the floor near (b) (4) (sample site (b) (4)1) and during your Cleaning Validation C630-H-00; PARTS WASHER in the rinse solution at the (b) (4). C. Your firm failed to identify gram negative environmental isolates from (b) (4) and (b) (4) systems even when action and alert limits are exceeded. The exceeded alert and action limit isolates are only characterized as "Absence Indicator Organisms." Between 2024 and 2026 there were 21 GNR (Gram Negative) isolates either exceeding alert or action limits that were not identified and only characterized as "Absence Indicator Organisms." D. Your firm failed to review the integrity of environmental monitoring (EM)

    Shortened here; the PDF has the full text.

  3. 3

    Failure to follow receiving and storage procedures

    OBSERVATION 3 Written procedures are not followed for the receipt, storage and handling of. Specifically, A. Your firm failed to document and complete the Purchasing Notification of Missing Documents Form (SOP21-076 Form B) in your locked Quarantined cage for the following incoming shipments: i. (b) (4) (Material (b) (4)), Lot (b) (4) received on 16-FEB-2026 ii. (b) (4) (Material# (b) (4)) received on 11-MAR-2026 iii. (b) (4) materials (Lot# (b) (4)) received on 11-MAR-2026 These items have not been issued the SOP21-076 Form B. This issue was not resolved within the required time or escalated to the Warehouse and Quality Management Team as required by SOP21-076, Receiving Process, Rev. 32, Effective Date: 24-NOV-2025 section 5.5.1. which states, "If the shipment is missing the proper documentation or is incorrect or incomplete, immediately email the Sourcing and Procurement, Materials Management and Incoming Quality departments a complete copy of SOP21-076 Form B (Purchasing Notification of Missing Documents). If the issue is not resolved within (b) (4) escalate the issue to the Warehouse and Quality Management team." Your Quality Assurance Manager stated that Form B has not been filled out for all materials missing documents upon receipt and the procedure has not been followed. B. Your firm failed to place materials in the specified locations in your (b) (4) Storage (2-8°C) area as assigned in your inventory management system (b) (4) for the following products: i. Material (b) (4) Lot (b) (4) with Location (b) (4) was found in Location# (b) (4). ii. Material (b) (4) Lot (b) (4) with Location (b) (4) was found in Location# (b) (4). There is no assurance that materials received have been placed in the correct location as assigned in your inventory system to prevent product mix-ups.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 1000113778, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.