Skip to content

PETNET Solutions Inc.

California

FEI 3036193770DUNS 119452615

Company: PETNET Solutions, Inc. · Linked by exact D-U-N-S match (015223951) in FDA registration data

FDA has one inspection on file for PETNET Solutions Inc. in California (FEI 3036193770). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for PET drug production, through Dec 31, 2027. Its registrant, PETNET Solutions, Inc. (D-U-N-S 015223951), has registered 43 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jul 15, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unqualified supplier for critical precursor component

      You did not use a reliable supplier as a source of each lot of component. Specifically, Your firm failed to follow procedure SOP # D0011306 titled "Supplier Qualification, Approval, and Maintenance," Revision H (Effective Date: 11/1/2025), which establishes requirements for vendor selection, approval, and oversight. For example: A. Your firm failed to show (b) (4) as an approved supplier of the precursor (b) (4) mg/vial), a critical component used in the manufacture of (b) (4) Injection. There are no supplier qualification activities performed prior to introducing the precursor (b) (4) into the manufacture of (b) (4) process validation (PV) batches of (b) (4) Injection (Batch #s (b) (4) In addition, the HPLC identity test performed to receive the precursor raw material at central facility is not specific to confirm the identity of precursor that yields as an active ingredient. B. Your firm accepted transfer tubing — a material used during product transfer in the manufacture of (b) (4) Injection — without obtaining a specification sheet to verify material specifications. In addition, there is no documentation to show that this supplier is qualified.

    2. Observation 2

      Inadequate visual inspection procedure and qualification

      An appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications was not conducted before final release. Specifically, A. Your procedure D0001978, Product Test: Appearance, effective 10/23/24 is not adequate. The procedure does not include the use of contrast background for visual inspection of final product to determine visible particle matter, color and clarity. B. The qualification (b) (4) used for qualification of visual inspection of the operators is not adequate. The (b) (4) of (b) (4) vials in which (b) (4) vials only contain (b) (4) of (b) (4) ((b) (4) particle). The (b) (4) is not representative for identifying all particulate matters and defects.

    Show observations 3 to 5
    1. Observation 3

      Missing radiochemical yield action limits

      Your master production and control records did not include a statement of action limits on radiochemical yield. Specifically, A. The manufacturing batch records for (b) (4) Injection do not include action limits on radiochemical yield. For example, Manufacturing batch record for PPQ batch # (b) (4) on page 3 of 26 Section, Final Product Vial Assay and Sterility Inoculations, the radiochemical yield is only recorded, however, there is no statement on action limits on radiochemical yield beyond which investigation and corrective action are required. B. The document (D0009777) "Investigations for Low Radiochemical Yields and Failed Batches in the Production (b) (4) Labeled Products," states that the action limit for radiochemical yield for (b) (4) (b) (4) labelled product as (b) (4). The firm cannot provide any scientific rationale for the (b) (4) action limit, considering the firm manufactured around (b) (4) batches of (b) (4) injection and the obtained yield for these batches was around 65%.

    2. Observation 4

      Inadequate aseptic technique and personnel training

      You lack personnel with the necessary background and training to perform their assigned functions. Specifically, On 05/19/2026, during a production mock preparation of final product vial subassembly conducted under the ISO 5 (b) (4) laminar airflow hood (LFH SN: (b) (4), the operator (b) (6), (b) (7) did not follow techniques described in SOP D0011940, Preparation of Final Product Vial Subassembly – (b) (4) (b) (4) Revision: Q, Effective Date: 03/13/2025. The operator failed to follow aseptic techniques as specified in the instructions of SOP D0011940. For example: A) The operator did not apply (b) (4) to their gloved hands prior to re-entering the ISO 5 critical zone. B) The operator placed the environmental monitoring (EM) settle plate cover face up of the in the critical zone during active aseptic operations. C) Materials and components were positioned in front of one another, obstructing first-air flow. D) During the cleaning, the operator did not employ (b) (4) wipe strokes. In addition, the operator used wipes from an already opened package. E) The operator did not (b) (4) and (b) (4) and (b) (4) on to the (b) (4) when performing personnel EM. We observed the operator conducted the personal EM with approximately (b) (4) motion touch for (b) (4) finger.

    3. Observation 5

      Failure to monitor laminar flow hood pressure

      You did not implement procedures to ensure that all equipment is cleaned and suitable for its intended purposes that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. Specifically, You failed to monitor the pressure differential of ISO 5 Laminar Flow Hood (#(b) (4)), to ensure the pressure differential across the filter face to indicate the HEPA filters function appropriately during the final product vials assembly.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 15, 2026. It asked for a Form 483.

  • Inspection ending May 22, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 15, 2026FDA-FOIA-2026-6728Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
PET drug production
Registration runs through
Dec 31, 2027
Registrant
PETNET Solutions, Inc.D-U-N-S 015223951

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names PETNET Solutions, Inc. (D-U-N-S 015223951) as the registrant for this site and 43 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as PETNET Solutions Inc.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3036193770 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3036193770. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.