FDA has 6 inspections on file for Jiangsu Hengrui Pharmaceuticals Co., Ltd. (Jinqiao Road Site) in Lianyungang, China (FEI 3006689263), from 2012 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below. Five of the nine FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling, analysis, sterilization and particle size reduction, through Dec 31, 2027. Its registrant, Jiangsu Hengrui Pharmaceuticals Co., Ltd. (D-U-N-S 654147255), has registered 3 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2012–2026
- 0 OAI · 2 VAI · 4 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 9 requests, latest Jul 27, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterilization validation smoke and load deficiencies
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process. Specifically, A. Smoke studies The review of the smoke study reports used to qualify the filling lines used in the aseptic filling of [redacted] API stated no obvious turbulence or reflux [redacted] Injection and [redacted] was observed. The following uneven air currents were not identified or investigated: 1. Turbulence was noted in the following videos used to evaluate air flow currents in grade A areas: Finished product line - Dynamic Inside the dispensing machine Dynamic in the (b)(4) Dynamic in the (b)(4) (b)(4) and forcep in (b)(4) area and forcep in (b)(4) area (b)(4) transferring at (b)(4) (b)(4) (b)(4) transferring at (b)(4) Sampling, (b)(4) (b)(4) cleaning (b)(4) cleaning Sampling, (b)(4) Stopper Area Static (b)(4) (b)(4) Stopper Area Static (b)(4) Remove the (b)(4) of the (b)(4) stopper (b)(4) API filling line (b)(4) canisters transferring (b)(4) Reset (b)(4) probe (b)(4) (b)(4) Transferring (b)(4) Stopper 2. Lack of adequate smoke over (b)(4) activities being evaluated: Finished product line (b)(4) and forcep in (b)(4) area (b)(4) Remove the (b)(4) of the (b)(4) (b)(4) Stopper API filling line (b)(4) canisters transferring 3. The Smoke leaving the wand is not perpendicular: Finished product line (b)(4) and forcep in (b)(4) area Stopper Area Static Smoke (b)(4) belt Fallen vials on the (b)(4) (b)(4) 4. Obstruction in front of video camera so cannot evaluate Finished product line (b)(4) Sampling, (b)(4) cleaning cleaning (b)(4) Sampling, (b)(4) API filling line (b)(4) canisters transferring - (b)(4) Validation B. (b)(4) 1. The positioning of the items is inconsistent between the minimum and maximum load patterns The load patterns are used to sterilize equipment and gowning API and (b)(4) Injection used in the manufacture of sterile (b)(4) stopper/utensil load pattern used in the manufacture of For example, the (b)(4) Injection: (b)(4) (b)(4) (b)(4) Injection, (b)(4) The aseptic filling of the (b)(4) (b)(4) The load pattern used to sterilize these items is not documented. This results in the load pattern not being validated. Details as to whether equipment is 2. There are no detailed pictures for how to load the (b)(4) stacked or laid side by side are not given. For the load pattern used in the sterilization of the API are shown in the picture. How the equipment/tools are loaded into equipment, (b)(4) is not provided. those (b)(4) 3. Tools used inside the grade A aseptic filling line for finished product (b)(4) Injection, do not have a sterilized hold time. These items do not have a sterilized hold time. The tools are stored in the grade B area and are not part of the environmental monitoring or (b)(4) program. The tools currently in use were sterilized 09Oct2025. 4. Risk assessment for BI locations, to determine the hardest to reach locations for (b)(4) sterilization has not been performed. Procedures do not specify or document the exact location of the BI placement during validation. Only general locations are specified. For an example from the (b)(4) validations, see below There is no assurance that the locations picked are the hardest to reach locations. C. Software Qualification: Your firm failed to adequately qualify the RABs (b)(4) filling equipment, equipment #(b)(4) The OQ/PQ protocol, V-F-P 59 203P, is inadequate this protocol only tested the equipment's ability to reject overfills and underfills but failed to demonstrate the equipment's ability to accurately and consistently confirm fill weights within acceptable limits. Additionally, the equipment lacks data storage capability, lacks in-process weight verification, and relies on operator transcription of displayed values without verification or electronic record retention. No audit trail exists for this software, Siemens Version 1.0. No electronic data can be provided for and no conveyer sp
Shortened here; the PDF has the full text.
- Observation 2
Sterile contamination prevention procedures not established
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. A. Visual Inspection 1. Your firm uses only one defect kit for operator training, ongoing requalification, and performance testing. This kit contains only one example of each defect type. Some of the defects have been in use for over four years, allowing operators to repeatedly view, and are tested on identical defects during each requalification cycle, allowing the same defects to be seen (b)(4) This practice does not adequately challenge operators to recognize defects they (b)(4) have not previously memorized. This practice also fails to demonstrate operators can identify defects based on understanding characteristics rather than memorize specific defects in the one training/defect kit and does not represent the variability of defects that may occur in actual production. 2. Your defect library consists solely of photographs of the same defects contained in the single qualification kit. With some defects having been photographed and used for more than four years without rotation or addition of new examples, operators are repeatedly exposed to identical visual references rather than a representative range of potential defects. 3. Visual defects in your qualification program are no less than 4 micrometers. This threshold may not adequately challenge operators to detect smaller, still significant, defects that could impact product quality. Your qualification program should include defects at or below the acceptance criteria to ensure operators can reliably detect rejectable defects. Specific particle defects included in the one defect/training kit include: (b)(4) 4. Your firm removes labels from bottles during qualification testing, but does not have a system to ensure accurate identification of which vial number corresponds to which label, creating the potential for incorrect scoring of operator performance, inability to verify which specific defects were correctly or incorrectly identified, and compromised integrity of the qualification process. 5. Requalification of visual inspectors is performed as a group rather than individually and does not replicate the exact manner in which batch release inspections are conducted. Group testing may allow operators to benefit from cues or behaviors of other operators which does not occur during routine individual inspection activities. 6. If a visual inspector fails requalification, your firm does not have a written procedure requiring the opening of a deviation or investigation. No process has been established to identify a root cause, assess whether previous batches inspected may have been inadequately inspected by the failed operator, and no requirement to implement a CAPA. B. Aseptic Technique The following inappropriate aseptic behaviors were noted during review of the smoke study and media fill videos associated with the aseptic filling of (b)(4) Injection: 1. Media fill (b)(4) The operator shook the (b)(4) stopper bag over the stopper bowl, bypassing the (b)(4) (b)(4) when the stoppers failed discharge from the bag. Operators are seen placing forceps and Tools are placed directly on equipment surfaces/floor of the (b)(4) RABs during An operator was seen leaning on the table in the grade B area. 2. (b)(4) the conveyer was not wiped Reject the inverted vial on the vial transfer track (b)(4) down after being touched by the operator. C. (b)(4) integrity testing The firms (b)(4) testing and integrity testing procedures are inadequate to ensure proper (b)(4) maintenance. 1. During the inspection, we observed unlabeled (b)(4) in the (b)(4) room and the (b)(4) filling room in Workshop (b)(4) on April 7, 8, 13, 2026. (b)(4) installed in the serial numbers, or any identifying information. are not labeled with installation date, (b)(4) (b)(4) (b)(4) are also not clearly defined. The lack of labeling prevents verification that testing results are recorded. appropriate (b
Shortened here; the PDF has the full text.
Show observations 3 to 11
- Observation 3
Deficient cleaning disinfection system for aseptic areas
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the [system/equipment] to produce aseptic conditions. Specifically, discrepancies were noted during the review of the (b)(4) validation for the following areas: A. API - (b)(4) used in the aseptic filling of The (b)(4) cycle was observed taking place on the (b)(4) API on 13Apr2026. During this activity along with the review of the procedures (b)(4) validation, the following discrepancies were noted: (b)(4) associated with (b)(4) cycle, or touching equipment during the (b)(4) were observed (b)(4) is (b)(4) are not put in place until after the (b)(4) (b)(4) including (b)(4) packages, settle plates, Various items were observed on the floor of the (b)(4) active air equipment/lid, cleaning hose and tools. There is no evidence that (b)(4) penetrates these areas. The justification for BI location, as well as the (b)(4) validation, does not consider the ancillary equipment/supplies located inside the (b)(4) RABs during validation. B. Finished product - (b)(4) RABs used in the The validation (V-F-P 59 242C) of the (b)(4) filling area, containing the (b)(4) Injection as well as the (b)(4) procedure followed prior to aseptic filling of (b)(4) RABs (b)(4) during routine production, does not specify whether or not the (b)(4) the (b)(4) A risk assessment located in the validation states if the equipment (b)(4) cannot reach all area during sterilization, resulting in insufficient sterilization effect. for the filling room as well The routine (b)(4) procedure (PO-59 008), performed NLT (b)(4) (grade A/B area), does not specify the placement or as the area outside of the API (b)(4) location of chemical indicators.
- Observation 4
Deficient environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Environmental Monitoring 1. Adequate risk assessment could not be provided for changing viable surface monitoring from RABs, are (b)(4) located in the (b)(4) to (b)(4) These (b)(4) for the (b)(4) used to handle settle plates during environmental monitoring. 2. Recovery studies have not been performed that show using one swab (b)(4) of a (b)(4) (b)(4) gives adequate recovery.
- Observation 5
Deficient separate areas and equipment maintenance
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. The following discrepancies were noted during review of the aseptic filling lines for the following: (b)(4) API (b)(4) 1. On April 9, 2026, I observed your firm failed to maintain equipment in a clean and orderly manner. The (b)(4) Sterile (b)(4) equipment (b)(4) was found to have the following deficiencies: Deep scratches and gouges on interior surfaces including: worktable inside the (b)(4) (b)(4) Floor surfaces inside the (b)(4) Several broken (b)(4) on the (b)(4) in the (b)(4) cannot be emptied into the canister without 2. The (b)(4) crossing first air above the (b)(4) This (b)(4) is refilled approximately (b)(4) times This was observed during the aseptic filling of (b)(4) API (b)(4) during the simulated fill performed on 14Apr2026, and during the smoke studies. Batch (b)(4) of sterile drug substance (b)(4) manufactured in this (b)(4) on November 19, 2025, was used for production of the sterile finished product (b)(4) (b)(4) Injection, Batch (b)(4) released on March 4, 2026, and shipped to the United States on (b)(4) (b)(4) Injection (b)(4) RABs) is 1. Deep scratches and gouges were observed on the interior surface where the (b)(4) placed. This is the area where sterile stoppers travel prior to being installed. blocks first air during the addition of (b)(4) stoppers. 2. The (b)(4) 3. Scientific justification could not be provided for delaying alarms for (b)(4) in critical areas (between the filling room (grade B) and the capping room (grade C) for pressure differential excursions. This delay is based on the air exchange in the grade D area. Pressure differentials are measured (b)(4) between these rooms while pressure differentials inside the (b)(4) RABs between these two areas (grade A to grade B with grade A air (b)(4) supply) is only measured [illegible]
- Observation 6
Inadequate cleaning maintenance procedures detail
Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance. The following discrepancies were noted during the review of cleaning activities which took place in the filling room on 8Apr2026. 1. Mop heads cannot be completely submerged in the cleaning bucket. The mop heads are used to clean the ceilings, walls, and floors of the API refining room and the finished product filling room, directly outside of the Grade A areas. I observed the operator submerging the mop head repeatedly, at different angles, attempting to submerge the entire mop head prior to cleaning. 2. Cleaning of the grade B room did not follow the sequence of cleaning listed in PO-59 006, i.e. ceiling, walls, equipment surface, floor.
- Observation 7
QC unit lacks oversight of aseptic operations
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products. Your firm failed to ensure adequate oversight during the installation of a (b)(4) valve within a Grade A aseptic processing environment RABS equipment #(b)(4) on April 8, 2026. Quality Assurance personnel were observed to be positioned away from the operation with obstructed views, preventing verification that aseptic techniques and environmental controls were maintained during this critical installation. Your SOPs ICC-A-206, Filling, and IC-A-207, Rev006, In-Process checks for (b)(4) Rev 006, In process Control of Aseptic (b)(4) (b)(4) is not sufficient to ensure aseptic processing evolutions are adequately observed by QA.
- Observation 8
TLC impurity method not stability indicating
The TLC test method for determining (b)(4) degradation impurities used during stability has not been proven to be stability indicating.
- Observation 9
Unproven method versus USP and peeling issue
The (b)(4) method (b)(4) used to test (b)(4) has not been proven to be better than or equal to the USP method. The firm's procedure does not include a (b)(4) with their edges peeling On 7Apr2026, I observed (b)(4) (b)(4) off the (b)(4)
- Observation 10
Failure to maintain clean drug substance equipment
There is a failure to maintain equipment in a clean and orderly manner to prevent contamination that could alter the quality of the drug substance. On April 7, 2026, during a walkthrough of the packaging area of Workshop (b)(4) particles were observed on equipment #(b)(4) and under the (b)(4) equipment # the surface of the (b)(4) and the room were signed off as "cleaned" on April 7, 2026. (b)(4) This (b)(4) Your firm's testing identified the particles as (b)(4) equipment are not dedicated, and are used for: This room, and (b)(4) API for the US market (b)(4) packaging of (b)(4) for the domestic market (b)(4) packaging of excipient (b)(4) for the US market (b)(4) packaging of the excipient (b)(4)
- Observation 11
Assay method not stability indicating
The (b)(4) method used during the assay testing of (b)(4) has not been proven to be stability indicating.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Nine requests to FDA under the Freedom of Information Act named this site, most recently on Jul 27, 2026.
Inspection ending Apr 15, 2026VAI
5 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 21, 2026FDA-FOIA-2026-6982Form 483Records released
- Jul 19, 2026FDA-FOIA-2026-6881Form 483Records released
- Jul 14, 2026FDA-FOIA-2026-6683Form 483Records released
- Jul 11, 2026FDA-FOIA-2026-6629Form 483 + EIRRecords released
- Jul 9, 2026FDA-FOIA-2026-6597Form 483Records released
Inspection ending Apr 13, 2018VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Aug 6, 2026. FDAgent holds no copy that FDA posted.
- Jul 27, 2026FDA-FOIA-2026-7176Form 483 + EIRRecords released
Inspection date not given
3 requests. FDA released records in answer to a request for its Form 483 + EIR on Jul 24, 2026. FDAgent holds no copy that FDA posted.
- Jul 23, 2026FDA-FOIA-2026-7119Inspection recordsRecords released
- Jul 20, 2026FDA-FOIA-2026-6917Form 483· 1 of 2 sitesWithdrawn
- Jul 14, 2026FDA-FOIA-2026-6681Form 483 + EIRRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, labeling, analysis, sterilization, particle size reduction
- Registration runs through
- Dec 31, 2027
- Registrant
- Jiangsu Hengrui Pharmaceuticals Co., Ltd.D-U-N-S 654147255
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Jiangsu Hengrui Pharmaceuticals Co., Ltd. (D-U-N-S 654147255) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Jiangsu Hengrui Pharmaceuticals Co., Ltd. (Huanghe Road Site)Lianyungang, China · FEI 30073735035 inspections5latestJan 16, 2024OAI1 warning letter, Jul 11, 2024
- Jiangsu Hengrui Pharmaceuticals Co., Ltd.Lianyungang, China · FEI 30116039692 inspections2latestApr 4, 2025VAINone on file
- Jiangsu Hengrui Pharmaceuticals Co., Ltd. (Dongjin Road Site)Lianyungang, China · FEI 30034041482 inspections2latestAug 29, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3006689263 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3006689263. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.