Skip to content

QuVa Pharma Inc Form 483, May 2026

FDA issued this Form 483 to QuVa Pharma Inc in Sugar La nd, Texas (FEI 3012053582) at the end of an inspection that ended May 4, 2026. It lists 3 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 1, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
May 4, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Jul 1, 2026
58 days after the inspection
Facility
FEI 3012053582
Sugar La nd, Texas

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate sterile contamination procedures

    Procedures designed to prevent microbiological contamination of [illegible] are not established, written and followed. Specifically, your firm failed to adequately establish procedures to prevent microbiological contamination of drug products purporting to be sterile. For example, A. Your firm failed to adequately define a [illegible] used by technicians to pick items off cleanrooms. The device storage location technicians hang the device on the side utensils, drug product containers, and finis[illegible] B. On 4/20/2026, during a site walk-through cleanroom, I observed a "black residue" near the drug components, utensils, drug product containers, and finis[illegible] within all ISO 7 cleanrooms. Your firm entire [(b)(4)] located within the ISO 7 cleanroom. C. Your firm's dynamic ISO 5 LAFH/BSC smoke studies were found to [illegible]. Smoke studies within the ISO 5 LAFH/BSCs fail to adequately assess laminar air flow patterns for actual production setup, aseptic processing components placement within the hood, and maximum drug filled syringes and IV bags within the area. Your firm's general manager stated new smoke studies will be performed to assess aseptic activities within ISO 5 LAFHs/BSCs.

  2. 2

    Insufficient investigation of HEPA/contamination

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, during a review of nonconformance number IR-12512 (DEV-02984) documented Nov 2024, prior to compounding Fentanyl Citrate PF 50 mc 10138352, Expiry 02/12/2025 compounding in ISO 7 Cleanroom Suite 7, ISO 5 LAFH numbered [illegible], your compounding technician found on the ISO 5 LAFH grate in front [illegible] a brown to black foreign residue contaminant, later within an investigation identified [illegible]. The sealant [illegible]. The sealant is applied during the HEPA filt[er] [illegible] particulates from the degradation may become an airborne contaminate affecting first quality used during aseptic processing of sterile drug product. The ISO 5 LAFH was removed from service, HEPA filter replaced by your firm's contract cleanroom re-certifier, re-certified, clean/disinfected, before returning to service in aseptically processing the product, Fentanyl Citrate PF 50 mc 700092168448, Lot 10138352. Your firm was unable to provide sufficient documented evidence in support of the HEPA filter degradation start and if Cleanrooms may have been impacted. Your quality unit failed to adequately investigate and document the potential HEPA filter degradation issues within other operational ISO 7 Cleanroom ISO 5 LAFHs and potentially released lots compounded in these units.

  3. 3

    Facility maintenance issues (peeling paint)

    Buildings used in the manufacturing, processing, packing and holding of [illegible] maintained in a good state of repair. Specifically, on 4/20/2026, during a site walk-through I observed paint peeling off Suite 3 ISO 8 Degowning Room wall corners and around the door frame.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3012053582, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.