Skip to content

Environmental monitoring in FDA Form 483 observations

Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
179
Each quoted below
Form 483s
116
Posted by FDA
Facilities
109
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 64 in 2026

Environmental monitoring observations in Form 483s by inspection year
YearObservations
20082
20090
20100
20110
20122
20130
20142
20152
201611
20179
20186
20195
20201
202114
202214
202313
202411
202523
202664

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.42(c)(10)(iv)

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 179 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Zhejiang Huahai Pharmaceutical Co. Ltd.Inspection ended Nov 18, 2016 · FEI 3003999190 · Observation 2

    OBSERVATION #2 Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. 1. Assessments to establish environmental monitoring sampling points were not comprehensive. For example, they did not evaluate expanded sampling points or thoroughly …

    Contains “environmental monitoring”Read the Form 483 →

  2. Zhejiang Huahai Pharmaceutical Co. Ltd.Inspection ended Nov 18, 2016 · FEI 3003999190 · Observation 4

    OBSERVATION #4 Data is not recorded contemporaneously. . ®@ © 1. The “checked by” entries for batch of Tablets were not documented at the time of batch production. 2. The QC analyst responsible for environmental monitoring does not document sampling at the time it occurs. It ‘was reported the analyst remembers the times and documents all at once after finishing.

    Contains “environmental monitoring”Read the Form 483 →

  3. Aurobindo Pharma Limited Unit 4Inspection ended Sep 16, 2016 · FEI 3008461619 · Observation 4

    The use of instruments and recording devices not meeting established specifications was observed. Specifically, the "Indu Softweb Studio" SCADA electronic recording system for temperatures found in the micro lab rooms for incubating Environmental Monitoring, Reference Cultures, and other media incubation shows multiple out-of-specification temperatures and loss of communication errors through June, July, and August 2016. As evidenced by repeated …

    Contains “environmental monitoring”Read the Form 483 →

  4. Indoco Remedies LimitedInspection ended Sep 4, 2016 · FEI 3005124189 · Observation 5

    … There is no continuous non-viable particle monitoring in the Grade A zone where operators use gloved hands to load the vial ®® and there is no assurance that vials will not become contaminated with particulates during this operation. b. Sterilized components such as ©O@ bottle ®® and caps, and stoppers for injectable products, are held outside the enclosed filling zone on top of a®® on Line ©}. The storage area is not enclosed or held under …

    Contains “non viable”Read the Form 483 →

  5. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 1

    … c) Media plates generated from Environmental Monitoring/Sampling and personnel testing, that are to be read by the Auto Colony Counter, are wiped free of their identification label showing date, location and employee tested if applicable, prior to being placed in the Auto Colony Counter for reading. The recorded digital photo taken by the Auto Colony Counter, showing results and colonies counted, does not include plate identification in the photo …

    Contains “environmental monitoring”Read the Form 483 →

  6. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 4

    … of jbl line utilized in the manufacture of drug products including “ of was inconclusive with regard to laminar air flow or the proper function of the air particle counter. e) Revalidation Protocol /MFIL . 2015 states that media fill studies on line(®) utilized to manufacture EOE © for the U.S. market, are performed EN

    Contains “particle count*”Read the Form 483 →

  7. Lupin LimitedInspection ended Jul 6, 2016 · FEI 3005906909 · Observation 1

    … 2016 with disinfectant solution according to SOP AMP-044-02, titled "Fumigation in Powder Processing Area", effective date 6/25/2016, after microbiological environmental monitoring alert levels were exceeded. The Powder Processing Areas are used in finished API production, for example for ®® (0) 4) and @® USP. When fumigation is to be done, the solution is aerosolized to cover the entire area of a room. The firm removes equipment and product …

    Contains “environmental monitoring”Read the Form 483 →

  8. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 1

    … The media fill had no documentation that fingertips were sampled for microbiological contamination, no documentation of environmental monitoring (gown, air, and surface), and the time duration of the media fill was not documented. There was no documentation that the (b)(4) were incubated and inspected for microbial [illegible]. Pharmacist in Charge, R.R. stated that during the media fill his gloves were [illegible] and [illegible] on the media …

    Contains “fingertip*”Read the Form 483 →

  9. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 3

    … Upon observation of environmental conditions during filling and Cyanocobalamin 1,100 mcg/mL performed by aseptic pharmacist (b)(4): a) No viable air monitoring was conducted during filling operations. c) The pharmacist was observed swabbing the surface. Swab with the technique of [illegible] Using those and another swab to swab the (b)(4) and plated it. Your firm would recover organisms on the surfaces. Your firm would not be able to identify the …

    Contains “viable”Read the Form 483 →

  10. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 6

    … Also, non-viable air [illegible]. The batch of approximately [illegible] vials (# of vials released was [illegible]) released by your Pharmacist in Charge on 2/1/16 based on [illegible] control testing lab (CTL). c) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) on vials of Ascorbic Acid 500 mg/mL bursting within the [illegible]. No documentation was provided. No documentation was provided for the …

    Contains “non viable”Read the Form 483 →

  11. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Air (viable and non-viable) sampling within all classified areas is not performed during daily [illegible]. Personnel stated that sampling is only performed every [illegible]. B. There is no continuous or at least periodically monitoring of air pressure differentials during production from the ISO 7 room containing the ISO 5 hoods …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  12. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 2

    OBSERVATION 2 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. a). Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm only monitors viable air counts (b)(4) and during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. b). Environmental monitoring for non-viable particulates in the ISO …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  13. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 3

    The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, A. During a review of your firm's 2014 - 2015 Environmental Monitoring analysis, smoke pattern studies, for sterile and non-sterile drug production ISO5 Classified (Sterile [illegible] Model #[illegible]) your [illegible] to perform these studies in the [illegible] and Non Sterile [illegible] dynamic state. On 4/1/2015, …

    Contains “environmental monitoring”Read the Form 483 →

  14. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 6

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no monitoring of viable particles, non-viable particles, work surfaces or personnel in the ISO 5 laminar flow hood where aseptic operations are performed.

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  15. Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm has never monitored viable air counts. b. Environmental monitoring for non-viable particulates in the ISO 5 zones is not performed under dynamic conditions. This was last performed on 10/18/13 …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  16. Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 1

    … For June, July and August of 2011 and 2012 there was an increase over action limit trending guidelines used by the firm for the presence of microorganisms in environmental monitoring data which represents a seasonal increase in the recovery of vegetative organisms.

    Contains “environmental monitoring”Read the Form 483 →

  17. Cangene CorporationInspection ended Jun 21, 2012 · FEI 3003153579 · Observation 10

    The SOP for Growth Promotion of media used for environmental monitoring is incomplete in that it does not specify the length of time test articles should be incubated.

    Contains “environmental monitoring”Read the Form 483 →

  18. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 6

    … door or the automated double doors, as typically operated, into the aseptic preparation area and the effects on unidirectional airflow [illegible] Active viable air sampling and the effects on unidirectional airflow

    Contains “viable”Read the Form 483 →

  19. Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 8

    The procedure "Surface Monitoring [illegible]" QC-019-02, version 03/11/2008 does not require personnel exiting the aseptic fill suite to [illegible] on the [illegible] Additionally, personnel monitoring observed on September 16, 2008 exhibited [illegible]

    Contains “personnel monitoring”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about environmental monitoring in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.