Absolute Pharmacy LLC Form 483, April 2016
FDA issued this Form 483 to Absolute Pharmacy LLC in Lutz, Florida (FEI 3011116100) at the end of a drug inspection that ended April 11, 2016. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 11, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 17, 2024
- 2,837 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate media fill qualification program
1: Procedures designed to prevent microbiological contamination established, written, and followed. *Repeated Observations from the previous Form FDA-483 Specifically: A. Media fills performed to qualify pharmacists is inadequate in that it did not closely simulate current processes encountered during preparation of drug products as per SOP No. 7. Upon review of media fill documentation the following deficiencies were found: a) None of the "qualified" aseptic pharmacists had adequate documentation that the media fill simulates current processes and represents worst-case conditions, (b)(4) which includes: gowning/re-gowning, fatigue, [illegible] behavior. There was [illegible] documentation that media fills are observed and behavior. b) The documentation for the media fill performed by (b)(4) of current practices. The media fill had no documentation that fingertips were sampled for microbiological contamination, no documentation of environmental monitoring (gown, air, and surface), and the time duration of the media fill was not documented. There was no documentation that the (b)(4) were incubated and inspected for microbial [illegible]. Pharmacist in Charge, R.R. stated that during the media fill his gloves were [illegible] and [illegible] on the media fill. There was no documentation [illegible] been conducting sterile operations for the past 4 months. c) The documentation for the media fill performed by (b)(4) of current practices as he only produced (b)(4) when he is currently allowed. The media fill had no documentation that fingertips were sampled for microbiological contamination, no documentation of environmental monitoring (gown, air, and surface), and the time duration was not documented. The media fill stated that (b)(4) therefore the Pharmacist in Charge, R.R. d) The documentation for the media fill performed by (b)(4) of current practices. The media fill had no documentation that fingertips were sampled for microbiological contamination, no documentation of environmental monitoring (gown, air, and surface), and the media fill was not documented. The media fill stated that (b)(4) (b)(4) Pharmacist in Charge, R.R. e) Your firm lacked a disqualification and re-qualification program for as [illegible] of batches or out-of-specification environmental sampling results are reported. (f) (partial line in original unreadable) (b)(4) inappropriate 10 mg/mL multidose 5 mL vials, lot # J13-15MCPL failed sterility testing. The previous media fill performed [illegible] not representative of current practices. However, no action [illegible] performing aseptic operations until a successful media fill.
- 2
Sterilization/lyophilization not validated
2; Procedures designed to prevent microbiological contamination include validation of the sterilization process. Specifically, a) Your firm's [process] used to sterilize Testosterone products has not been validated. (b)(4) (b)(4) are intended to [illegible]. b) (b)(4) are intended to [illegible]. c) Your firm's lyophilization (b)(4) performed in the (b)(4) Methylcobalamin and JGF has not been validated. This [illegible] and (b)(4) *Repeated Observations from the previous Form FDA-483
- 3
Deficient cleaning/environmental monitoring
3. Aseptic processing areas are deficient regarding the system for monitoring environmental conditions; cleaning and disinfecting the room and equipment to produce aseptic conditions. *Repeated Observations from the previous Form FDA-483 issued 11/19/14 and Warning Letter issued 4/27/15. Specifically, Upon observation of cleaning activities prior to sterile operations for Cyanocobalamin performed by aseptic pharmacist (b)(4) I noted the following deficiencies: a) Prior to working in the ISO 5 LAFW, the pharmacist only sanitized the [illegible] within the ISO 5 buffer room with (b)(4) sterile [illegible] ceiling, sides, and middle bar of the LAFW Hood where the [illegible] (b)(4) as well as the chair that [illegible] sits in during filling operations within [illegible] previously opened (b)(4) sterile (b)(4) wipes within the ISO components. The pharmacist also stated that this practice occurs within the ISO 5 buffer room. b) The pharmacist introduced a pump into the ISO 5 LAFW without first wiping down the pump and sterile (b)(4). B. Upon observation of environmental conditions during filling and Cyanocobalamin 1,100 mcg/mL performed by aseptic pharmacist (b)(4): a) No viable air monitoring was conducted during filling operations. c) The pharmacist was observed swabbing the surface. Swab with the technique of [illegible] Using those and another swab to swab the (b)(4) and plated it. Your firm would recover organisms on the surfaces. Your firm would not be able to identify the location of the positive sample.
- 4
No smoke study/air qualification deficiencies
4. Aseptic processing areas are deficient regarding air supply filters under positive pressure. Specifically, the latest ISO 5 hood completed on 1 (b)(4) by a contractor do[es] [illegible] under static or dynamic conditions with maximum number [illegible]. It was stated that the smoke study performed in the (b)(4) failed to conduct a smoke study in the ISO 5 buffer room to illustrate [illegible] from the ISO 5 Hood to the L (b)(4). *Repeated Observations from the previous Form FDA-483 issued 11/19/14 and Warning Letter issued 4/27/15.
- 5
Failure to investigate OOS/quality events
5. Any unexplained discrepancy or the failure of a batch and specifications shall be thoroughly investigated, whether [illegible] Specifcally, A. Your firm failed to establish and follow an Out of Specification (OOS) Procedure to conduct investigations when an OOS result were received by your [lab]. a) OOS for high potency 124.2% (spec.) (b)(4) sterile product, MIC+B1 225/50/50 + 1 mg/mL multidose 30 mL vials, lot of (b)(4) vials on 9/16/15 for distribution prior to receiving [illegible]. b) Your firm generated a Quality-Related Event Report "26% low volume" for the Cyanocobalamin 1,100 mcg/mL multidose 1[0] mL [illegible]; no investigation was conducted. There is no documentation within the batch record reworked. (b)(4) vials were pending release. The visual inspection was reviewed and released by the Pharmacist in Charge. This lot [illegible]. c) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) for a sterility failure for Testosterone Cypionate 210 mg/mL multidose [illegible]. No investigation was conducted by the firm or the control [testing] lab (CTL). Re-training of the pharmacist. This batch was rejected according [illegible] to the batch record. d) Your firm generated a Quality Related Event Report Form for an endotoxin failure for L-Carnitine 500 mg/mL multidose 30 mL vials, [illegible] conducted by the firm or the control testing lab (CTL). This batch was rejected according to the batch record. e) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) on [illegible] low potency for Methylcobalamin 10 mg. No lot # was [illegible]. No documentation was provided for the re-training of the pharmacist.
- 6
Failed SOPs for chemical procedures
6. Your firm failed to follow SOP No. 9.014 Procedures in [Chemicals]. As a result, your firm failed to conduct an [illegible] following: a) During the visual inspection of Testosterone Enanthate 210 mg/mL, pharmacist G.O.H observed two vials containing particulate. [illegible] distribution and it is unclear if the two vials containing [illegible] In addition, the batch record does not state that a (b)(4) sterilization. b) During the current FDA inspection, I reviewed the vials, lot # A2516MCPL. I observed that there was no [illegible] using an (b)(4). Also, non-viable air [illegible]. The batch of approximately [illegible] vials (# of vials released was [illegible]) released by your Pharmacist in Charge on 2/1/16 based on [illegible] control testing lab (CTL). c) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) on vials of Ascorbic Acid 500 mg/mL bursting within the [illegible]. No documentation was provided. No documentation was provided for the [illegible].
- 7
No validated depyrogenation/sterilization methods
7. There are no written standards or specifications, methods of sterilization, and methods of processing to remove pyrogenic properties. Specifically, a) The (b)(4) depyrogenation (b)(4) has not been adequately validated as the firm failed [illegible]. This process is used for all laboratory glassware (i.e. glass vials) used [illegible] products. b) The (b)(4) sterilization (b)(4) have not been adequately validated as the firm failed to [illegible]. This process is used for finished product vials, rubber stoppers and caps used in the filling [illegible] products. c) Glass vials and beakers that are depyrogenated in-house are not identified back to the depyrogenation (b)(4) / batch. *Repeated Observations from the previous Form FDA-483 issued [illegible].
- 8
Inadequate sterility/assay testing methods
8. For each batch of drug product purporting to be sterile and/or [illegible] testing to determine conformance to such requirements. *Repeated Observations from the previous Form FDA-483 issued 11/19/14 and Warning Letter issued 4/27/15. Specifically, A. Testing and release of drug product for distribution do not include appropriate laboratory determination satisfactory conformance to the final specifications and identity and strength prior to release. a) Your firm has not validated sterility and endotoxin testing to ensure substances in your product formulations do not interfere with the test for the following products: MIC+B1. During the review of the method suitability for sterility testing for [illegible] your control testing lab (CTL) stated that your firm's drug product interferes with [illegible]. Your firm did not receive [illegible] actions needed to be taken. b) Your firm has never performed testing to determine the preservative effectiveness of your liquid sterile drug products prior to distribution: vitamin B12, Methionine/Inositol/Choline Chloride (MIC) + vitamin B12 and MIC + vitamin B1 + vitamin B12. c) Your firm has never tested the potency or reconstitution time for Chorionic Gonadotropin 1,000 IU prior to distribution.
- 9
Expiration dates unsupported by stability data
9. Results of stability testing are not used in determining expiration dates. Specifically, your firm lacked valid analytical and sterility data to support the following expiration dates applied to your sterile drug products: a) 6-month expiration date assigned to HCG 11,000 IU. b) 3-month expiration date assigned to MIC+B1+B12 25/25/25 mg/mL + 25 mcg/mL. c) 3-month expiration date assigned to Lysine HCL 200 mg injectable. d) 3-month expiration date assigned to Taurine 75 mg/mL injectable.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3011116100, newest first.
- Form 483, November 2014Inspection ended Nov 19, 2014 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.