FDA issued this Form 483 to Cangene Corporation in Winnipeg, Canada (FEI 3003153579) at the end of a biologics inspection that ended June 21, 2012. It lists 10 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 27, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 21, 2012
Biologics · Blood and Blood Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 27, 2026
5,241 days after the inspection
Facility
FEI 3003153579
Winnipeg, Canada

The 10 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate investigation of VIGIV filter fouling

    The firm's investigation into (b)(4) process interruptions for VIGIV bulk lots (b)(4) was inadequate. For example: A. The material leading to fouling of the (b)(4) was not identified. The manufacturing process for VIGIV bulk lot (b)(4) was reinitiated after the process automation stopped the process due to a (b)(4) across the (b)(4) This resulted in the stripping of the fouling material from the (b)(4) and precluded identification of the fouling material. The subsequent VIGIV bulk lot (b)(4) also demonstrated evidence of filter fouling. The manufacturing process was continued and no attempt was made to examine the (b)(4) to identify material retained on the (b)(4) (b)(4) B. The corrective actions identified in CAPA 219683 as a result of investigations described in deviation 208223 and deviation 211915 failed to prevent (b)(4) fouling in VIGIV bulk lot (b)(4) Specifically, exclusion of specific (b)(4) lots of plasma did not preclude (b)(4) fouling.

  2. 2

    No individual reject rates for defect categories

    There are no individual reject rates established for each defect category that is classified as (b)(4) The reject rate established is cumulative for all (b)(4) defects. Change Control 219756 dated June 11, 2012 was implemented to change the cumulative reject rate for (b)(4) defects, such as (b)(4) associated with Microbial contamination" from (b)(4) to a cumulative reject rate of (b)(4) for the WinRho (liquid formulation), HepGamB (Liquid), and Vaccinia Immune Globulin (VIG) products. A. (b)(4) are categorized as (b)(4) defects as opposed to (b)(4) "(b)(4) is categorized as a (b)(4) Defect. B. There are no individual reject rates established for the (b)(4) and (b)(4) defect categories for the WinRho (liquid formulation), HepGamB (Liquid), and Vaccinia Immune Globulin (VIG). A cumulative reject rate of (b)(4) is applied for both categories of defect

  3. 3

    Inadequate reinspection procedures after AQL failure

    Not all lots of product that fail the Acceptable Quality Limit (AQL) after the initial (b)(4) inspection is performed are reinspected under tightened limits for both the additional (b)(4) reinspection performed by production or the AQL performed by Quality. For example: Deviation 212555 was initiated on May 29, 2012 for HepaGam B lot (b)(4) using 3mL Vial Lot (b)(4) having an atypical number of (b)(4) defects (classified as a (b)(4) defect), detected during the initial (b)(4) (b)(4) inspection process. The Acceptable Quality Limit for this inspection also failed the acceptance criteria as a vial with the (b)(4) defect was detected. The lot was 100% reinspected for this defect. There were no reject limits established for this 2nd reinspection and there was no AQL performed for this reinspection. This lot was reinspected a third time under a tightened limit of (b)(4) and failed to meet this criteria with additional (b)(4) defects being found. Additional lots of product that were affected by this deviation were also reinspected and failed either the reinspection and/or the AQL for the (b)(4) defect of (b)(4) There are no procedures in place which address the criteria for the reinspection of lots that fail the initial (b)(4) inspection or an AQL. Additionally, there are no procedures in place which address the limit for the number of reinspections that can be performed on any given lot.

  4. 4

    Lack of control over critical documents

    There is a lack of assurance that there is adequate control over critical documents including, but not limited to, Policies, Standard Operating Procedures (SOPs), Work Instructions (WIs) Forms, Electronic Templates (ETs) Drawings and Manuals. The firm's Record and Information Department (R&D distributes controlled documents to a (b)(4) (b)(4) (b)(4) (b)(4) in which documents are to be returned is not always effective in that numerous incidences were observed where obsolete documents have been used by operators and technicians and have resulted in deviation investigations. Examples include, but are not limited to: A. Deviation Report #122799, dated August 11, 2010, documents the most current revision of pH calibration document not being used in the QC Raw Materials laboratory. The investigation states that the (b)(4) (b)(4) did not replace the old document with a newer version of the procedure. B. Deviation Report #197739, dated October 21, 1011 [illegible], documents that an incorrect version of a form was being used for raw material testing in the QC Microbiology laboratory. The (b)(4) did not print the new revision on its appropriate effective date and the analyst did not check the revision prior to using it.

  5. 5

    Uncontrolled printing of electronic controlled documents

    SOP 25.026.0002.01.00, (b)(4) defines a controlled document as (b)(4) (b)(4) documents are not always controlled: The printing, and circulation of such A. The firm uses (b)(4) software as a system for maintenance of controlled documents. This allows for documents to be (b)(4) for use in various departments. There is a lack of assurance that there is adequate control over controlled documents available to operators on (b)(4) Users who have access to the system are allowed to print off any of the effective controlled forms and procedures without accountability for these documents.

  6. 6

    Inadequate deviation classification for quality impact

    The firm's deviation control system is inadequate in that it fails to adequately assess the classification of deviations that may affect product quality. Specifically, during manufacture of Liquid WinRho lot (b)(4) and HepaGam B lot (b)(4) the (b)(4) was exceeded. There is a lack of assurance that the product impact for these lots was adequately addressed in that these deviations were classified as (b)(4) Deviations" that are used (b)(4) Per SOP 10.060.0023.20.19, QA Batch Record Review, (b)(4) Deviations require (b)(4) (b)(4)

  7. 7

    Unapproved routine rework by relabeling

    Deviation 109218 was initiated on June 7, 2010 for HepaGam B Finished Goods lot (b)(4) having been processed in Packaging using an incorrect process specification revision. This lot was reworked by being delabeled and relabeled into Finished Goods lot numbers 11006874 and 11006886. There is no approval in the license for routine rework. These lots have been distributed in the US and are within expiration dating.

  8. 8

    Written procedures not always followed

    Written procedures are not always followed. The (b)(4) treatment module of the batch record (Document number 24.5002.08, step 17, page 24 of 35) specifies a (b)(4) As described in deviation 211915, the (b)(4) was terminated early during manufacture of VIGIV lot (b)(4)

  9. 9

    No change-out period for product hoses

    There is no defined change out period for product contact flexible hoses used in manufacturing.

  10. 10

    Incomplete growth promotion SOP missing incubation time

    The SOP for Growth Promotion of media used for environmental monitoring is incomplete in that it does not specify the length of time test articles should be incubated.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3003153579, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.