Skip to content

Emergent BioSolutions Canada Inc.

155 Innovation Dr, Winnipeg, Canada

FEI 3003153579DUNS 203508049

Company: Emergent BioSolutions Inc. · Linked by exact D-U-N-S match (173570271) in FDA registration data

FDA has 7 inspections on file for Emergent BioSolutions Canada Inc. in Winnipeg, Canada (FEI 3003153579), from 2010 to 2019. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Four FOIA requests asked FDA for 483s from two later inspections that FDA's Data Dashboard doesn't list yet, the latest ending May 12, 2026.

2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant, Emergent BioSolutions Inc. (D-U-N-S 173570271), has registered 2 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2010–2019
0 OAI · 7 VAI · 0 NAI
Inspections with 483 observations shown
3 of 7
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
4 requests, latest Jul 28, 2026
Warning letters
None on file
Import refusals
2 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Improper sterile boot cover handling

      Procedures designed to prevent microbiological contamination followed. Specifically, on 09/06/2019, during the filling equipment [illegible] the outside of his sterile boot covers to unfold the vinyl boot soles. Procedures specifically require employees to only place their sterile, gloved hands inside and to only grasp the vinyl boot sole from inside the sterile boot cover.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigation of VIGIV filter fouling

      The firm's investigation into (b)(4) process interruptions for VIGIV bulk lots (b)(4) was inadequate. For example: A. The material leading to fouling of the (b)(4) was not identified. The manufacturing process for VIGIV bulk lot (b)(4) was reinitiated after the process automation stopped the process due to a (b)(4) across the (b)(4) This resulted in the stripping of the fouling material from the (b)(4) and precluded identification of the fouling material. The subsequent VIGIV bulk lot (b)(4) also demonstrated evidence of filter fouling. The manufacturing process was continued and no attempt was made to examine the (b)(4) to identify material retained on the (b)(4) (b)(4) B. The corrective actions identified in CAPA 219683 as a result of investigations described in deviation 208223 and deviation 211915 failed to prevent (b)(4) fouling in VIGIV bulk lot (b)(4) Specifically, exclusion of specific (b)(4) lots of plasma did not preclude (b)(4) fouling.

    2. Observation 2

      No individual reject rates for defect categories

      There are no individual reject rates established for each defect category that is classified as (b)(4) The reject rate established is cumulative for all (b)(4) defects. Change Control 219756 dated June 11, 2012 was implemented to change the cumulative reject rate for (b)(4) defects, such as (b)(4) associated with Microbial contamination" from (b)(4) to a cumulative reject rate of (b)(4) for the WinRho (liquid formulation), HepGamB (Liquid), and Vaccinia Immune Globulin (VIG) products. A. (b)(4) are categorized as (b)(4) defects as opposed to (b)(4) "(b)(4) is categorized as a (b)(4) Defect. B. There are no individual reject rates established for the (b)(4) and (b)(4) defect categories for the WinRho (liquid formulation), HepGamB (Liquid), and Vaccinia Immune Globulin (VIG). A cumulative reject rate of (b)(4) is applied for both categories of defect

    Show observations 3 to 10
    1. Observation 3

      Inadequate reinspection procedures after AQL failure

      Not all lots of product that fail the Acceptable Quality Limit (AQL) after the initial (b)(4) inspection is performed are reinspected under tightened limits for both the additional (b)(4) reinspection performed by production or the AQL performed by Quality. For example: Deviation 212555 was initiated on May 29, 2012 for HepaGam B lot (b)(4) using 3mL Vial Lot (b)(4) having an atypical number of (b)(4) defects (classified as a (b)(4) defect), detected during the initial (b)(4) (b)(4) inspection process. The Acceptable Quality Limit for this inspection also failed the acceptance criteria as a vial with the (b)(4) defect was detected. The lot was 100% reinspected for this defect. There were no reject limits established for this 2nd reinspection and there was no AQL performed for this reinspection. This lot was reinspected a third time under a tightened limit of (b)(4) and failed to meet this criteria with additional (b)(4) defects being found. Additional lots of product that were affected by this deviation were also reinspected and failed either the reinspection and/or the AQL for the (b)(4) defect of (b)(4) There are no procedures in place which address the criteria for the reinspection of lots that fail the initial (b)(4) inspection or an AQL. Additionally, there are no procedures in place which address the limit for the number of reinspections that can be performed on any given lot.

    2. Observation 4

      Lack of control over critical documents

      There is a lack of assurance that there is adequate control over critical documents including, but not limited to, Policies, Standard Operating Procedures (SOPs), Work Instructions (WIs) Forms, Electronic Templates (ETs) Drawings and Manuals. The firm's Record and Information Department (R&D distributes controlled documents to a (b)(4) (b)(4) (b)(4) (b)(4) in which documents are to be returned is not always effective in that numerous incidences were observed where obsolete documents have been used by operators and technicians and have resulted in deviation investigations. Examples include, but are not limited to: A. Deviation Report #122799, dated August 11, 2010, documents the most current revision of pH calibration document not being used in the QC Raw Materials laboratory. The investigation states that the (b)(4) (b)(4) did not replace the old document with a newer version of the procedure. B. Deviation Report #197739, dated October 21, 1011 [illegible], documents that an incorrect version of a form was being used for raw material testing in the QC Microbiology laboratory. The (b)(4) did not print the new revision on its appropriate effective date and the analyst did not check the revision prior to using it.

    3. Observation 5

      Uncontrolled printing of electronic controlled documents

      SOP 25.026.0002.01.00, (b)(4) defines a controlled document as (b)(4) (b)(4) documents are not always controlled: The printing, and circulation of such A. The firm uses (b)(4) software as a system for maintenance of controlled documents. This allows for documents to be (b)(4) for use in various departments. There is a lack of assurance that there is adequate control over controlled documents available to operators on (b)(4) Users who have access to the system are allowed to print off any of the effective controlled forms and procedures without accountability for these documents.

    4. Observation 6

      Inadequate deviation classification for quality impact

      The firm's deviation control system is inadequate in that it fails to adequately assess the classification of deviations that may affect product quality. Specifically, during manufacture of Liquid WinRho lot (b)(4) and HepaGam B lot (b)(4) the (b)(4) was exceeded. There is a lack of assurance that the product impact for these lots was adequately addressed in that these deviations were classified as (b)(4) Deviations" that are used (b)(4) Per SOP 10.060.0023.20.19, QA Batch Record Review, (b)(4) Deviations require (b)(4) (b)(4)

    5. Observation 7

      Unapproved routine rework by relabeling

      Deviation 109218 was initiated on June 7, 2010 for HepaGam B Finished Goods lot (b)(4) having been processed in Packaging using an incorrect process specification revision. This lot was reworked by being delabeled and relabeled into Finished Goods lot numbers 11006874 and 11006886. There is no approval in the license for routine rework. These lots have been distributed in the US and are within expiration dating.

    6. Observation 8

      Written procedures not always followed

      Written procedures are not always followed. The (b)(4) treatment module of the batch record (Document number 24.5002.08, step 17, page 24 of 35) specifies a (b)(4) As described in deviation 211915, the (b)(4) was terminated early during manufacture of VIGIV lot (b)(4)

    7. Observation 9

      No change-out period for product hoses

      There is no defined change out period for product contact flexible hoses used in manufacturing.

    8. Observation 10

      Incomplete growth promotion SOP missing incubation time

      The SOP for Growth Promotion of media used for environmental monitoring is incomplete in that it does not specify the length of time test articles should be incubated.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on Jul 28, 2026. Each one asked for a Form 483.

  • Inspection ending May 12, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Aug 10, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 28, 2026FDA-FOIA-2026-7216Form 483· 1 of 2 sitesRecords released
  • Inspection ending Aug 27, 2025

    3 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 + EIR on Mar 20, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 2, 2026FDA-FOIA-2026-2127Form 483 + EIRRecords released
    2. Nov 20, 2025FDA-FOIA-2025-13126Form 483· 1 of 4 sitesWithdrawn
    3. Date not givenFDA-FOIA-2026-4138Form 483 + EIRWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 7 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003153579, one row per refused product line.

2 refusals from 2021-02-26 to 2023-04-25 · charged NO PMA on 1, NOT LISTED on 1 · no FDA sample analysis

FDA firm profile
  • 2023-04-25

    COVID 19 VACCINE57CL33

    NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION

    Division of Southeast Imports799-4102918-3/11/1

  • 2021-02-26

    REAGENTS, 2019-NOVEL CORONAVIRUS NUCLEIC ACID83QJR

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    REGISTERED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast Imports799-0923117-6/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Emergent BioSolutions Inc.D-U-N-S 173570271

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Emergent BioSolutions Inc. (D-U-N-S 173570271) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003153579 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003153579. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.