Environmental monitoring in FDA Form 483 observations
Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 179
- Each quoted below
- Form 483s
- 116
- Posted by FDA
- Facilities
- 109
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 64 in 2026
| Year | Observations |
|---|---|
| 2008 | 2 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 2 |
| 2013 | 0 |
| 2014 | 2 |
| 2015 | 2 |
| 2016 | 11 |
| 2017 | 9 |
| 2018 | 6 |
| 2019 | 5 |
| 2020 | 1 |
| 2021 | 14 |
| 2022 | 14 |
| 2023 | 13 |
| 2024 | 11 |
| 2025 | 23 |
| 2026 | 64 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 179 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 2
Equipment for adequate control over micro-organisms is not always provided when appropriate for the manufacture, processing, and packing of drug substances. a) Filling equipment (b) Block Module (b)(1) (grade A) is located in a position where aseptic procedures for operators during filling include bending down and squatting, which may result in bellowing of viable and non-viable particulate from personnel gowning during these activities having a …
Contains “viable”Read the Form 483 →
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 3
… exposed stopper packaging materials within the airflow of intervention activities and in a quantity and location intended to optimize detection of potential viable environmental contaminants during aseptic operations.
Contains “viable”Read the Form 483 →
Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 1
Personnel and environmental monitoring conducted within the ISO 5 Environments on a[(o)14) l frequency are deficient. Specifically, your firm does not perform growth promotion for each batch of media purchased or use a positive control when conducting'.(15) (4) gloved finger assessment and surface sampling. Your firm conducts gloved fingertip test and surface sampling as part of the compounding personnel qualification.
Contains “environmental monitoring”Read the Form 483 →
Hieber’s PharmacyInspection ended Jul 17, 2019 · FEI 1000121499 · Observation 1
Procedures designed to identify and prevent insanitary conditions are not established and followed by your firm. Specifically, Your firm did not perform appropriate environmental monitoring in your aseptic processing areas. For example, pressure differentials between areas with different air classifications were not monitored before or during sterile drug production. The air pressure differential between the ISO 5 (b) (4) and the ISO 7 clean room …
Contains “environmental monitoring”Read the Form 483 →
Sun Pharmaceutical Industries Ltd.Inspection ended Jun 11, 2019 · FEI 3002809586 · Observation 2
OBSERVATION 2 Established laboratory control mechanisms are not documented at the time of performance. The assurance of the data from the all analytical testing data is not provided. Specifically, Environmental monitoring of plates on June 5, 2019 included review of more than [illegible] sample sets. In my review of the data in support of the EM review, it was noted that in selected examples, the primary reviewer performed the plate analysis …
Contains “environmental monitoring”Read the Form 483 →
Auro PharmaciesInspection ended Aug 2, 2018 · FEI 3011893599 · Observation 2
OBSERVATION 2 You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, you had viable air monitoring samples above action levels [(b) (4)] consecutively in January, February and March of 2018 in ISO 5 hoods that are used in the production of sterile drugs. Your firm continued to …
Contains “viable”Read the Form 483 →
Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 6
… All connections are performed in an open ISO 8 environment without environmental monitoring during unit operation. The [illegible] connection requires more than [illegible] of open exposure because [illegible] of [illegible] must be [illegible] from the transfer line, prior to making the open hose connection to the [illegible]. In addition, your firm identified the open hose connections as the root cause for the out-of-specification bioburden …
Contains “environmental monitoring”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 8
… Your firm did not perform appropriate environmental monitoring in your aseptic processing areas. For example, a. Environmental monitoring of surfaces for microbial contamination is not performed each day after completion of sterile operations in the ISO 5 area. Your firm performs such monitoring only on a (b)(4) basis, and after cleaning the surfaces. b. Technicians' gloves are not monitored for microbial contamination after completion of sterile …
Contains “environmental monitoring”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 8
Environmental monitoring in your aseptic processing areas is not adequate. Specifically, a. Review of the last (b)(4) Environmental Monitoring report, dated 11/30/17, revealed that Micrococcus species and Aspergillus was detected when viable air sampling was conducted in the ISO-5 Laminar Air Flow Hood. As a corrective action, your firm performed cleaning (b)(4) times in the controlled environment, and air sampling was repeated. An investigation …
Contains “environmental monitoring”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 10
… Demonstration of the effectiveness of the cleaning operations was not assessed because environmental and personnel monitoring was not performed afterward.
Contains “personnel monitoring”Read the Form 483 →
Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 3
… The firm does not include this uncontrolled refrigerated pass through in its environmental monitoring.
Contains “environmental monitoring”Read the Form 483 →
Shilpa Medicare LimitedInspection ended Nov 30, 2017 · FEI 3009876430 · Observation 5
… During the validation of the microbial method used during the analysis of environmental monitoring plates, the actual conditions of use are not validated. The firm does not demonstrate that the microbial growth media provides conditions such that compromised and/or stress organisms are able to propagate within a varied microbial population. In addition, the media used for the [illegible] plate method does not undergo growth promotion for how it …
Contains “environmental monitoring”Read the Form 483 →
I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 5
OBSERVATION 5 Sterility Assurance is not adequate Surface samples collected inside the ISO 5 LAF Hood on (b)(4) basis are not incubated at (b)(4) C per manufacturer instruction. We observed the plates being incubated at (b)(4) without an incubator at approximately [illegible].
Contains “surface sampl*”Read the Form 483 →
Vital Rx, Inc. dba Atlantic Pharmacy and CompoundingInspection ended Jul 20, 2017 · FEI 3011775721 · Observation 4
Your form does not perform environmental monitoring for microorganisms. You are not monitoring your sterile ISO 5 laminar flow hood which is used to produce sterile drug products for intrathecal, ophthalmic, and IV infusion use: 1.) You have not performed viable air particle testing 2.) You do not perform surface testing of the laminar flow hood bench 3.) You do not test gloves or suits worn and used during the preparation of sterile drug …
Contains “environmental monitoring”Read the Form 483 →
ARJ Infusion Services, Inc.Inspection ended May 25, 2017 · FEI 3013452490 · Observation 1
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. You have not performed your media fill during worst case processing conditions of your sterile processed drugs. B. Your main pharmacy technician has not performed a media fill at your current address. C. You have not performed dynamic smoke studies in your laminar air flow hood. D. Air pressures are not monitored during sterile …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Pharmacy Associates, Inc.Inspection ended May 24, 2017 · FEI 3009145318 · Observation 7
Observation #7: Environmental monitoring was not performed in your aseptic processing areas. a.) Personnel Monitoring is not being performed by your firm. Per your firm management, your firm does not have the (b) (4) to perform this testing. Furthermore, the firm does not monitor compounding personnel (i.e. gloved fingers).
Contains “environmental monitoring”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 1
… Non-viable particle monitoring is only conducted (b) (4). Filling can be conducted (b) (4) (b) (4) (b) (4). There is only (b) (4) sampling point inside of the laminar flow area. The sample volume is (b) (4) (b) (4) (b) (4). This does not ensure the environment remains in a state of control during routine operations or interventions. There is lack of scientific rationale for the sampling locations. For example, no sample is taken in the laminar …
Contains “non viable”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 4
… Non-viable particle monitoring data from room (b) (4) is recorded on laminated sheets of paper. The data recorded on the sheet can be erased. 4. Paper shredders are present in the QC laboratory and production area offices.
Contains “non viable”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 7
Failure to perform a thorough investigation into a discrepancy. 1. During environmental monitoring of the (b) (4) filling area, numerous alert and action level findings were not thoroughly investigated. From April-June 2015 there were 5 alert and 3 action level investigations opened for monitoring of the (b) (4). A thorough investigation with root cause evaluation and preventive actions was not performed. Trending analysis conclusions recommended …
Contains “environmental monitoring”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 11
… Microbiologists document in the (b) (4) system that all settle plates are exposed before starting to put out the settle plates.
Contains “settle plate*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule30
- 21 CFR 211.113Control of microbiological contamination27
- 21 CFR 211.160General requirements6
- 21 CFR 211.192Production record review5
- 21 CFR 211.100Written procedures; deviations3
- 21 CFR 211.22Responsibilities of quality control unit2
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2
- 21 CFR 211.194Laboratory records2
Ask FDAgent about environmental monitoring in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.