FDA has 10 inspections on file for Bayer AG in Leverkusen, Germany (FEI 3002806462), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Mar 22, 2019. FDA issued a warning letter on (CDER). 27 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.110(a) and 21 CFR 211.67(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling, analysis and particle size reduction, through Dec 31, 2027. Its registrant, Bayer AG (D-U-N-S 315034629), has registered 4 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
10, 2010–2025
2 OAI · 6 VAI · 2 NAI
Inspections with 483 observations shown
3 of 10
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jan 6, 2021
Import refusals
27 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    3. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Prevention of cross contamination, mix-ups

      There is insufficient physical or spatial separation from operations and other drug products to prevent mix-ups and cross-contamination.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Identification of containers, lines, equipment

      All processing lines and major equipment used during the production of a batch of drug product is not properly identified at all times to indicate contents and the phase of processing of the batch.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and parameters relevant to the operation.

    3. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    4. Labels and labeling stored separately

      Labels and other labeling materials are not stored separately with suitable identification for each different drug product, strength, dosage form or quantity of contents.

    5. Following/documenting laboratory controls

      Established laboratory control mechanisms are not followed.

    Show 1 more citation
    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic filling environmental controls

      Failure to ensure appropriate environmental conditions for filling parenteral products. (b) (4) and (b) (4) are (b) (4) sterilized parenteral products filled in room (b) (4) classified as a Grade C area for the filling environment with laminar flow over the filling machine. The (b) (4) in which the products are filled contain an open port until (b) (4). This open port is exposed to the environment for an extended period of time from the time the (b) (4) are taken out of their packaging through the filling process, which could be (b) (4) or more. Control of environmental contaminants during the exposure of these open bags has not been thoroughly demonstrated with established procedures and monitoring. For example: 1. The operators manually handle the (b) (4) and were observed to lean over the (b) (4) with open ports while putting them on the filling line, disrupting laminar flow. The operator's gloves and gowns were observed to touch the (b) (4) ports. The operators handling the (b) (4) have exposed skin on their faces. 2. During interventions into the laminar flow area near the printing station, the (b) (4) with open ports are not removed after the operators work above them. 3. Non-viable particle monitoring is only conducted (b) (4). Filling can be conducted (b) (4) (b) (4) (b) (4). There is only (b) (4) sampling point inside of the laminar flow area. The sample volume is (b) (4) (b) (4) (b) (4). This does not ensure the environment remains in a state of control during routine operations or interventions. There is lack of scientific rationale for the sampling locations. For example, no sample is taken in the laminar flow area where the operators are manually handling the open bags. 4. Smoke studies to demonstrate laminar air flow are not representative of all operations. For example, use of particle and viable air samplers near the filling machine is not demonstrated. During smoke studies there were less stacks of (b) (4) waiting to be put on the line than what occurs in routine production. 5. Environmental monitoring including active air, passive air, and surface monitoring only occurs (b) (4). Sampling locations have not been established based on a scientific assessment to identify the most critical locations and locations most relevant to the dynamic operations occurring in the filling area.

    2. Observation 2

      Inadequate visual inspection for particulates

      Procedures to ensure reliable detection of particulate matter in parenteral products have not been established. 1. During routine visual inspection, filled (b) (4) are visually inspected immediately after exiting the filling area. The filling process introduces (b) (4) bubbles that create cloudiness in the solution that takes a (b) (4) to subside. This cloudiness was observed to be present at the time of the visual inspection and could obscure particulate matter. This cloudiness would not be present during qualification of the visual inspection operators. 2. Routine visual inspection occurs on-line with operators (b) (4) in (b) (4) approximately (b) (4) from the (b) (4) to be inspected. During the qualification the operators work offline with (b) (4) they are holding in their hands. 3. During routine visual inspection (b) (4) move on a conveyor that does not turn or invert the bag to allow for full inspection. During qualification the operators manually hold the (b) (4) allowing it to be fully inspected. 4. Routine visual inspection of (b) (4) by the operator at the (b) (4) background station is occurring at up to (b) (4) (b) (4) per minute. During the qualification the operator is permitted up to (b) (4) minutes to inspect (b) (4) (b) (4).

    Show observations 3 to 11
    1. Observation 3

      Inadequate equipment and facility cleaning procedures

      Procedures for cleaning of the equipment and facility are not established and followed. 1. The (b) (4) building has (b) (4) (b) (4). They are not product dedicated, including (b) (4) (b) (4) that are shared use between (b) (4) products and non-(b) (4) products. Cleaning validation of the equipment failed to evaluate hard to clean and hard to visually inspect places, such as the (b) (4). Inspection of the (b) (4) (b) (4) revealed: a. The "clean" (b) (4) in room (b) (4) had unidentified white residues coating the surfaces of the (b) (4) valve facing the air flow and at the edges around an unused spray ball. This cleaning of the (b) (4) duct is not described in a procedure for the manual cleaning of this piece of equipment. b. The "clean" (b) (4) (b) (4) 400/(b) (4) had white powder in the (b) (4). This cleaning of the (b) (4) is not described in a procedure for the manual cleaning of this piece of equipment. c. The "clean" (b) (4) in room (b) (4) had white particles in the (b) (4). This area is cleaned with a spray ball. Validation of the cleaning process did not include sampling or inspection of this area. 2. In room (b) (4) in the (b) (4) department during ongoing production of (b) (4) on 19 January 2017, (b) (4) residues were observed on exterior surfaces of the equipment. The previous product, (b) (4), was (b) (4) in color. 3. On 19 January 2017, (b) (4) equipment BLF-632-1 was in use at the time of inspection. The equipment cleaning had not been inspected and the documentation was not signed as approved by a supervisor. 4. No clean hold times or dirty hold times have been established for equipment in the (b) (4) department. 5. Black, mold like material was observed on the wall of an office in the (b) (4) department. 6. For room (b) (4) used for filling of parenteral products: a. Unidentified black material was observed on the ceiling of the room and on the grates of the HEPA filters in the laminar flow area. Unidentified (b) (4) material was observed on top of (b) (4) inside of the laminar flow area. b. Cleaning activities observed on 13 January 2017 showed that wiping of all surfaces was not completed. For example, all of the (b) (4) that hold the open (b) (4) or (b) (4) inside of the laminar air flow barrier. c. Cleaning inside the laminar flow area was not done in a unidirectional, (b) (4), and from (b) (4) manner. d. A sporicidal is not used as part of the routine disinfection process.

    2. Observation 4

      No document control and data integrity failures

      A document control system has not been established. 1. There is no document control system to track issuance and use of GMP documents in the production area. Production personnel print or copy from the master copies and there is no process to reconcile the use of the forms. The following GMP documents were observed in a waste bin on 13 January 2017: a. Partial batch record (b) (4) for (b) (4) Tablets. It was partially completed for the start of the (b) (4) process. The batch record reviewer did not note that this portion of the batch record was missing when the batch record was reviewed and approved. This portion was later discarded. b. Two cleaning records related to (b) (4) FPL (b) (4) on 12 January 2017. It was reported a mistake was made on the form where the original data was recorded. The operator re-wrote the data onto a new form and discarded the original. c. Numerous partially filled set-up forms for mounting of equipment associated with the start of (b) (4) campaigns were found in the waste bin. These included forms that were completely missing from batch records where the batch record reviewer did not detect the missing document and forms that were rewritten due to apparent incorrect information. d. Numerous set-up parameter forms for setting tablet visual inspection parameters were observed in the waste bin. The original documents should have been maintained as part of the raw data for setting of parameters. Additionally, some of the discarded forms had been written using pencil. e. Numerous original signed training records were found in the waste bin. The original records are required to be maintained per SOP 3-040-127. 2. In the microbiology laboratory, duplicate sets of records containing raw data for the same personnel clean room qualification documentation were observed. The analyst stated the raw data from the copied sheets is later transferred to the official sheet and the forms with original raw data are discarded. 3. Non-viable particle monitoring data from room (b) (4) is recorded on laminated sheets of paper. The data recorded on the sheet can be erased. 4. Paper shredders are present in the QC laboratory and production area offices.

    3. Observation 5

      Inadequate complaint investigations and follow-up

      Failure to conduct thorough complaint investigations and extend the investigation to related batches. 1. Complaint 2015-015988 received 30 April 2015 and complaint 2015-016372 received 05 May 2015 documented leakage from (b) (4) bags where the (b) (4) connected to the bag on batch (b) (4) of (b) (4). Investigation determined a packaging material defect could be the root cause. The investigation failed to identify other batches which used the same packaging material. No retain samples of the affected batch were examined. Follow-up with the (b) (4) supplier was made 08 June 2015 and the supplier confirmed a deviation related to (b) (4) parameters for the (b) (4) had occurred on one of the related (b) (4) batches. The complaint investigation failed to assess this information and make an evaluation of the product distributed to the market that used this lot of (b) (4). A complaint for leakage at the same location was received for batch (b) (4) documented in complaint 2016-026147 received 31 May 2016. No retain samples were evaluated and no further action was taken. 2. The complaint handling procedure 3-020-082 does not describe evaluation of retain samples during complaint investigations. Retain samples were not evaluated when foreign matter was reported in the following complaints: 2015-009605 dark particles in solution for batch (b) (4) of (b) (4), 2016-020559 fiber in solution for batch (b) (4) of (b) (4), 2016-007422 small fibers in batch (b) (4) of (b) (4). 3. The complaint handling procedure 3-020-082 does not describe when analytical testing of returned complaints samples will be conducted. Complaint 2015-024059 documented a cluster of four adverse events for rashes at the injection site for batch (b) (4) of (b) (4). The remaining portion of the shipment was returned, but analytical evaluation of the returned product was not included as part of the investigation.

    4. Observation 6

      Failure to prevent cross-contamination between areas

      Failure to establish separate areas to prevent cross contamination. There is no process to analytically measure pressure differentials between production rooms and common corridors in the non-product dedicated (b) (4) production plant. (b) (4) are used to indicate the air flow between areas, but operators are not always present to ensure the proper flow of air during production activities. On 19 January 2017, the (b) (4) between the (b) (4) room for ongoing (b) (4) (an (b) (4) product) production, and the change room did not appear to show significant pressure differential. Not all areas which manufacture (b) (4) products have dedicated change areas to enter and the production rooms open directly to the common corridors, including (b) (4) room (b) (4) and tableting rooms. After entering production suites which contain dust from (b) (4) products, there is no gowning requirement to ensure operators do not transfer dust to other areas of their facilities on their shoes.

    5. Observation 7

      Inadequate discrepancy and OOS investigations

      Failure to perform a thorough investigation into a discrepancy. 1. During environmental monitoring of the (b) (4) filling area, numerous alert and action level findings were not thoroughly investigated. From April-June 2015 there were 5 alert and 3 action level investigations opened for monitoring of the (b) (4). A thorough investigation with root cause evaluation and preventive actions was not performed. Trending analysis conclusions recommended increasing the cleaning frequency of this area, however this was never implemented. Additional alert and action results were observed at this point in September of 2015. The investigations were written as standalone reports that failed to evaluate other points in the same area that also had alert or action level findings during the same time period. 2. Investigation into the finding of Paneibacillus lactis during active air monitoring at the filling machine on 25 February 2016 failed to include thorough evaluation of the root cause and impact to product for endotoxin. 3. There is no process to ensure root cause evaluations of organisms detected that are not expected to be the normal microbial flora of the filling environment, such as Gram negative organisms, fungi, spore forming organisms. 4. Investigation into three OOS results during assay testing of (b) (4) during sample set (b) (4) (b) (4) (b) (4) invalidated the OOS results due to shifts in retention time during the sequence. The standards passed system suitability and no limits had been established for retention time drift. No evaluation of previous analytical runs, which also showed retention time drifts, including sample set (b) (4) (b) (4) were performed. Additionally, no limits were established for acceptable retention time drift.

    6. Observation 8

      Unsuitable facility and equipment design

      Facilities and equipment are not of a suitable design for their intended use. 1. The (b) (4) system has dead legs in the solution preparation department (point (b) (4)) and in an equipment washing area (points (b) (4)) of the (b) (4) plant. 2. Room (b) (4) is used to fill parenteral products. The floor and (b) (4) section of the wall are constructed of (b) (4) (b) (4) that does not create a smooth surface.

    7. Observation 9

      Failure to maintain and review analytical data

      Failure to maintain and review all analytical data. 1. Until June 2016, analysts performed HPLC injections identified as "test" or other similar names and injections with no sample name at all. The content of these injections and their purpose were not documented and were never reviewed. For example, review of the 2015 project folder for assay and impurity testing of (b) (4) (b) (4) Tablet show that out of (b) (4) total injections, approximately 157 injections are identified with a name of "test" or similar and 6 were unnamed injections. 2. Repeat testing of IR was performed after abnormal results were generated. There was no documentation to explain what had occurred and the original data was not submitted for review. For example, sample (b) (4) was first tested on 12 January 2016 and was retested 14 January 2016. 3. The software used for performing in process weight checks is set to not report any data that is not plausible, defined as data with more than a (b) (4)% variation of expected results. The full set of data is not printed and evaluated by an operator to verify the reason for data that is not plausible. Review of audit trail entries for 19 January 2017 observed two non-conforming data points that were not reported and were not further evaluated.

    8. Observation 10

      Missing audit trail and integration procedures

      Test procedures for analytical testing have not been established. 1. No procedures have been established to review audit trails for the laboratory software systems. Examples include, but are not limited to, Empower (Chromatography), Opus (IR Spectroscopy), and Disso Net (Dissolution by UV). 2. Manual integration of chromatograms is permitted. Procedures describing when manual integration can be performed, how it is to be performed, and how it will be reviewed have not been established.

    9. Observation 11

      Non-contemporaneous data recording practices

      Data is not recorded contemporaneously. 1. Production and laboratory personnel do not document contemporaneously. The practice of signing for multiple steps all at once is permitted. 2. Supervisors reviewing logs signed one page rather than each individual page requiring a signature. 3. Microbiologists enter results into the electronic (b) (4) system for multiple samples all at one time during plate reading. 4. Microbiologists document in the (b) (4) system that all settle plates are exposed before starting to put out the settle plates.

  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jan 6, 2021.

  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Jan 6, 2021FDA-FOIA-2021-153EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 10 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002806462, one row per refused product line.

27 refusals from 2017-11-30 to 2026-01-26 · charged UNAPPROVED on 24, NOT LISTED on 2 · no FDA sample analysis

FDA firm profile
  • 2026-01-26

    ASPIRIN (ANALGESIC)60LCY05

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7770178-5/30002/1

  • 2026-01-20

    RIVAROXABAN61LDY42

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-9203188-7/10002/1

  • 2025-09-03

    RIVAROXABAN61LCA42

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsF23-9339962-1/110002/1

  • 2025-09-03

    RIVAROXABAN61LCA42

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsF23-9339758-3/110002/1

  • 2025-07-23

    ASPIRIN (ANALGESIC)60LAA05

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7261205-2/32/1

Show 22 more
  • 2025-07-16

    LEVONORGESTREL (ESTROGEN)64GDY29

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    RX LEGEND 502(a) & (f)(1), 801(a)(3); MISBRANDING

    Division of Southeast Imports9UA-0323395-6/72/1H

  • 2022-01-31

    CHLORPHENIRAMINE MALEATE (ANTI-HISTAMINIC)61XCA08

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0333993-2/21/1

  • 2021-11-22

    ASPIRIN (ANALGESIC)60LCY05

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-8421813-7/51/1

  • 2021-07-16

    RIVAROXABAN61LDA42

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-9373110-4/41/1

  • 2021-06-01

    CYPROTERONE ACETATE (ANTI-ANDROGEN)61BCA02

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-2442037-4/11/1

  • 2020-12-09

    DEXPANTHENOL (CHOLINERGIC)63NAY04

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-3032449-7/11/1

  • 2020-09-11

    MISCELLANEOUS PATENT MEDICINES, ETC.66VBL99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northern Border ImportsSCS-1575402-3/11/1

  • 2020-07-14

    RIVAROXABAN61LCB42

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7575552-7/11/1

  • 2020-06-16

    ASPIRIN (ANALGESIC)60LAA05

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7203607-1/11/1

  • 2020-06-16

    ESTRADIOL (ESTROGEN)64GDA07

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7188763-1/11/1

  • 2019-11-26

    INHIBITOR N.E.C.64UDY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-6585460-3/11/1

  • 2019-11-04

    ANTI-COAGULANT, N.E.C.61LDA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-6471823-9/11/1

  • 2019-09-17

    CIPROFLOXACIN (ANTI-BACTERIAL PART I) (NOT ANTIBIOTIC)61FDA54

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAEK-6319789-8/21/1

  • 2019-06-19

    ANTI-COAGULANT, N.E.C.61LCA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-1931158-7/11/1

  • 2018-11-28

    INHIBITOR N.E.C.64UCA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-1711729-3/11/1

  • 2018-11-08

    ANTI-COAGULANT, N.E.C.61LDL99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-1387073-9/11/1

  • 2018-09-19

    ASPIRIN (ANALGESIC)60LCA05

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-0775202-6/21/1

  • 2018-09-13

    ETHINYL ESTRADIOL (ESTROGEN)64GDY19

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-0537326-2/11/3

  • 2018-08-09

    ETHINYL ESTRADIOL (ESTROGEN)64GDA19

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-5024232-7/11/1

  • 2018-07-16

    NEOMYCIN PALMITATE (ANTI-BACTERIAL) (NOT ANTIBIOTIC)61GBJ06

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-6671359-3/21/1

  • 2018-04-25

    ANTI-COAGULANT, N.E.C.61LDA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-5018310-0/11/1

  • 2017-11-30

    ASPIRIN (ANALGESIC)60LDY05

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast Imports799-3340086-0/21/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis, particle size reduction
Registration runs through
Dec 31, 2027
Registrant
Bayer AGD-U-N-S 315034629

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Bayer AG (D-U-N-S 315034629) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Bayer AGBergkamen, Germany · FEI 30028080847 inspections7latestNov 14, 2024VAI1 warning letter, Aug 5, 2009
  • Bayer AGBerlin, Germany · FEI 30028080869 inspections9latestJun 6, 2024VAINone on file
  • Bayer AktiengesellschaftBerlin, Germany · FEI 30028080635 inspections5latestJun 16, 2023VAINone on file
  • Bayer AGWuppertal, Germany · FEI 30032294868 inspections8latestJan 18, 2023VAINone on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002806462 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002806462. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.