Ranier's Compounding Laboratory
1107 Lowry Ave, Jeannette, Pennsylvania, United States
FEI 3012124170
FDA has 4 inspections on file for Ranier's Compounding Laboratory in Jeannette, Pennsylvania (FEI 3012124170), from 2016 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
The most recent OAI inspection ended on May 22, 2018. FDA issued a warning letter on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2016–2024
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- Observation 1
Insects observed in production area
Vermin or other animals or evidence of their presence was observed in the production area. Specifically, on 02/05/2024, I observed three ceiling lights in your general compounding lab area that contained one to two apparent dead insects. Examples of non-sterile products being made during the inspection on 02/05/2024 includes the following: Drug Name form Expiration Date Lot Number Enalapril 1 MG/0.25 mL Suspension 08/03/2024 020524-4 Pimobendan 0.5 MG/0.25 mL Suspension 04/03/2024 020524-3 Furosemide VET CMPD 10 MG/mL Suspension 08/03/2024 020524-6 Guanfacine 1 MG/mL Suspension 02/19/2024 020524-2 Repeat Observation from 2021 FDA 483.
- Observation 2
Non-pharmaceutical grade ingredient used
Use of ingredients not intended for pharmaceutical use in non-sterile drug production. Specifically, you failed to purchase and use the appropriate compendial grade components when preparing and producing human and veterinary drug products. A store brand ingredient, [(b)(4)] was used in the preparation of Lidocaine/ Prilocaine/ Tetracaine/ Phenylephrine 12.5/2/12.5/3% Dental Paste, Lot 113023-1, Beyond Use Date: 01/30/2024, and Lot 091823-1, Beyond Use Date: 10/18/2023. Both products were distributed to the patients for use.
Show 2 more observations
- FDCA 501(a)(2)(A)
Vermin, production area/adjacent areas
Vermin or other animals or evidence of their presence was observed in the production area.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical, ingredients/processing aides
Use of ingredients not intended for pharmaceutical use in non-sterile drug production.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Vermin and insects in production area
Vermin was observed in your production area. Specifically, on 08/06/2021, I observed six ceiling lights in your general compounding lab area and one ceiling light in the hallway to your hazardous compounding room to contain two to 12 apparent dead insects. Furthermore, I observed a cracked ceiling light that sits approximately 24 inches directly above hood (b)(4) in your general compounding lab and approximately an 0.25-inch gap in the ceiling light within your hazardous compounding room. Examples of non-sterile product being made during the inspection on 08/06/2021 includes the following: Drug Name, form, Expiration Date, Lot Number: Aluminum Hydroxide 135mg/ml, suspension, 08/20/2021, 080621-7; ABH 0.5/20/0.5 mg/1ml, gel, 02/02/2022, 080621-6; Biest (80:20)/ Testosterone 0.5/1mg/ml, cream, 02/02/2022, 080621-8; BMX Mouthwash 1:1:1, suspension, 02/02/2022, 080621-2; Guanfacine 1mg/ml, suspension, 08/20/2021, 080621-5; Progesterone (veg capsules) 100mg, capsules, 02/02/2022, 080621-1; Vancomycin 250mg/5ml, solution, 08/20/2021, 080621-3; Gabapentin 10mg/ml (VET), suspension, 10/01/2021, 080621-4.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Gloved hands touched non-sterile surfaces
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6) the technician was observed touching non-sterile components and equipment on the cart outside of the ISO 5 classified area and then continuing with aseptic processing without first sanitizing hands with (b)(4) each time or changing gloves.
- Observation 2
Personnel with exposed hair in ISO 5
Personnel engaged in aseptic processing were observed with exposed hair. Specifically, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6), Cefazolin 50 mg/mL Ophthalmic solution lot 151618-1CR for Rx (b)(6), and Tobramycin 14 mg/mL Ophthalmic solution lot 151618-2CR for Rx (b)(6) the technician's hair was observed as not fully covered while working in the ISO 5 hood.
Show observations 3 to 9
- Observation 3
Non-disinfected equipment introduced
Equipment and materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, the technician was repeatedly observed handling packaged and unpackaged components with bare hands before and while disinfecting the components with (b)(4) immediately before introduction into the pass through. In addition, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6), the technician was observed introducing non-sterile pliers into the ISO 5 critical zone without first disinfecting the surface of the pliers that was used to remove the closure of a sterile 100 mL glass bottle.
- Observation 4
Inadequate sporicidal agents used
The use of sporicidal agents in the ISO 5 classified aseptic processing area was inadequate. Specifically, the (b)(4) and the (b)(4) used to disinfect the ISO 5 area and the clean room are not effective as sporicidal agents at the specified concentration and contact time.
- Observation 5
Non-sterile disinfectants and wipes used
Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, the (b)(4) the firm prepares and uses in the ISO 5 hood is not sterile. Non-sterile lint free wipes are used to clean and disinfect the ISO 5 hood. The technician uses these non-sterile wipes that are kept in a stack, with no covering, on a cart in the clean room.
- Observation 6
Poor personnel/material flow and gowning
Your facility was designed and/or operated in a way that permits poor flow of personnel and materials. Specifically, The Prep room is unclassified and is where in-house sterilized glassware used in the aseptic preparation of drug products is stored. The technician was observed to move repeatedly between the ISO 8 classified gowning room and unclassified areas to retrieve components and transit through plastic curtains that are also contacted by employees who are not properly gowned. Between the general pharmacy and the gowning room, and between the gowning room and the Prep room, are plastic curtains that are not cleaned. Before production of Tobramycin 14 mg/mL Ophthalmic solution lot 151618-2CR for Rx (b)(6) the pharmacist checking the formula worksheets and components was observed without gowning walking from the unclassified general pharmacy through the gowning room (ISO 8) before entering the Prep room to perform the checks and then back from the unclassified Prep room through the gowning room to exit. Immediately before production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6), Cefazolin 50 mg/mL Ophthalmic solution lot 151618-1CR for Rx (b)(6), and Tobramycin 14 mg/mL Ophthalmic solution lot 151618-2CR for Rx (b)(6) the technician was observed donning sterile gloves inside the ISO 5 hood.
- Observation 7
Non-microbial contamination observed
Non-microbial contamination was observed in your production area. Specifically, white residue was observed on the face panel of the HEPA filter supplying air to the ISO 5 area. In addition, the floor of the ISO 7 clean room has visible dirt, stains, or residue that are not removed during routine cleaning.
- Observation 8
Inadequate certification and monitoring procedures
Procedures designed to identify and prevent insanitary conditions are not established and followed by your firm. Specifically, 1. Your firm did not ensure appropriate certification of your aseptic processing areas. For example, a. During certification of your aseptic processing area on 02/12/18, testing showed pressure differential failure between the gowning room and the unclassified general pharmacy. This failure was not corrected until 03/15/18. Between 02/12/18 and 03/15/18, your firm produced approximately [illegible] sterile drug products. b. Your aseptic processing areas were certified on 02/12/18 and 08/09/17. However, the certification reports issued indicate that HEPA filter leak testing was not conducted. In addition, the 08/09/17 certification report indicates that a smoke study was not conducted. c. The smoke study performed in your firm's ISO 5 hood on 02/12/18 did not assess airflow at the work surface under dynamic operational conditions. The video showed the smoke stream was localized near the middle back of the hood and the tube from which the smoke emanated remained stationary throughout the test. 2. Your firm did not perform appropriate environmental monitoring in your aseptic processing areas. For example, a. Environmental monitoring of surfaces for microbial contamination is not performed each day after completion of sterile operations in the ISO 5 area. Your firm performs such monitoring only on a (b)(4) basis, and after cleaning the surfaces. b. Technicians' gloves are not monitored for microbial contamination after completion of sterile operations. Glove tips are monitored only on a (b)(4) basis, and only the dominant hand is sampled. c. Your firm's incubator was sent out for repair between January 6, 2017 and February 8, 2017. During that time, no glove or surface sampling or testing was performed either in-house or by an outside laboratory. Between January 6, 2017 and February 8, 2017 your firm produced at least [illegible] sterile drug products. d. Your firm does not monitor differential pressure between the ISO 8 classified gowning room and the unclassified general pharmacy, and between the ISO 8 classified gowning room and the unclassified Prep room, before or during sterile drug production. 3. Your media fills are not representative of your firm's routine aseptic processing practices and do not incorporate appropriate worst-case activities and conditions that challenge your aseptic operations. For example, your firm's procedure does not describe use of the same equipment, glassware, (b)(4), and container-closure system your firm uses, and does not represent the largest volume of drug products you aseptically produce. 4. Biological indicators are not used to verify the adequacy of the sterilization cycle of (b)(4) to sterilize your firm's glassware used in sterile operations. In addition, the effectiveness of this cycle to depyrogenate the glassware has not been verified through performance of an endotoxin challenge. Additionally, you have no data to support that your glassware remains sterile throughout the storage period.
- Observation 9
Dust-collecting overhangs not cleaned
The ISO 5 classified aseptic processing areas and segregated production areas surrounding the ISO 5 classified aseptic processing area contained dust-collecting overhangs without adequate and frequent cleaning. Specifically, there are horizontal, flat surfaces above the ISO 5 hood. Those are not cleaned during routine cleaning, and the hired (b)(4) cleaning services do not include the ISO 5 hood. In addition, there are other such surfaces in the ISO 7 clean room including but not limited to the top of the pass through.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 2 more citations
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012124170 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012124170. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.