Skip to content

ARJ Infusion Services, Inc. Form 483, May 2017

FDA issued this Form 483 to ARJ Infusion Services, Inc. in Lenexa, Kansas (FEI 3013452490) at the end of a drug inspection that ended May 25, 2017. It lists 3 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
May 25, 2017
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,428 days after the inspection
Facility
FEI 3013452490
Lenexa, Kansas

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate environmental monitoring system

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. You have not performed your media fill during worst case processing conditions of your sterile processed drugs. B. Your main pharmacy technician has not performed a media fill at your current address. C. You have not performed dynamic smoke studies in your laminar air flow hood. D. Air pressures are not monitored during sterile drug production or at any other time to ensure adequate or (b) (4) are maintained in your anteroom, (b) (4) room and laminar air flow hood. I observed sterile processing of Normal Saline/Sodium Chloride 0.9% (identified by raw material lot (b) (4) and (b) (4)) conducted by your Pharmacy Technician in your laminar air flow hood on 5/16/2017 and 5/17/2017.

  2. 2

    Damaged/poorly maintained equipment design

    Equipment used in the processing, sterile drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. Specifically, A. I observed your laminar air flow hood with an area of rust with (b) (4) applied over it consisting of approximately 1/4" x 1'. (b) (4) B. I observed your laminar air flow hood with a crack along its overhead paneling ( ) consisting of approximately 1 linear foot.

  3. 3

    Inadequate cleaning and disinfecting procedures

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, I observed sterile processing of Normal Saline/Sodium Chloride 0.9% (identified by raw material lot (b) (4) and (b) (4)) conducted by your Pharmacy Technician in your laminar air flow hood on 5/16/2017 and 5/17/2017. During sterile processing, I observed the following inadequate aseptic techniques employed: • your Pharmacy Technician's beard cover left exposed skin and hair • inadequate/infrequent use of (b) (4) upon entry/re-entry into the laminar air flow hood • cleaning of the laminar air flow hood was not performed per your procedure(s) • components were not adequately cleaned before placement into the laminar air flow hood • written cleaning procedures and records do not verify the use of sporicidal cleaning agents used to clean the laminar air flow hood.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterApr 2, 2018CDER · 312 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.