Apitoria Pharma Private Limited
Unit-V, Plot No. 68-70,73-91,95,96,260,261 I.D.A., Pashamylaram Village, Patancheru Mandal, Sangareddy, India
FEI 3004051616DUNS 918917634
Company: Apitoria Pharma Private Limited · Linked by exact D-U-N-S match (861179030) in FDA registration data
FDA has 9 inspections on file for Apitoria Pharma Private Limited in Sangareddy, India (FEI 3004051616), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, Apitoria Pharma Private Limited (D-U-N-S 861179030), has registered 6 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 9, 2009–2025
- 0 OAI · 7 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 9
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Apr 1, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate laboratory OOS procedures
Laboratory controls do not always include the establishment of scientifically sound and appropriate procedures designed to assure that drug substances conform to appropriate standards of identity, strength, quality and purity. Specifically, when there is no scientific basis found for invalidating initial out-of-specification (OOS) API test results and no assignable cause for the OOS is determined, procedures (pZQA005) allow re-testing (following Phase I and II investigations), which permits reporting the average of [illegible] additional analyses performed by (b)<> separate analysts that meet specifications as the final data, overcoming original OOS data (No retests to overcome original OOS data have been reported).
- Observation 2
Inadequate microbial control equipment
Equipment for adequate control over micro-organisms is not always provided when appropriate for the manufacture, processing, and packing of drug substances. a) Filling equipment (b) Block Module (b)(1) (grade A) is located in a position where aseptic procedures for operators during filling include bending down and squatting, which may result in bellowing of viable and non-viable particulate from personnel gowning during these activities having a potential affect on the sterile drug substance (e.g., (b)(1) injection-bulk). b) Goggles used by operators to protect against exposed skin in the Grade A/B areas during aseptic operations have built-in unprotected openings (holes) in the top, creating a lack of protection against a source of particles generated by, and microorganisms shed from, the body, having a potential affect on the sterile drug substance.
Show observations 3 to 4
- Observation 3
Insufficient environmental monitoring
The aseptic processing area is deficient regarding the system for monitoring environmental conditions. During aseptic operations in Block Module (b)(1) in grade A where sterilized stoppers are unsealed and transferred to the filling area (along with depyrogenated (b)(4) canisters), there is an absence of continuous monitoring of viables in the immediate proximity of exposed stopper packaging materials within the airflow of intervention activities and in a quantity and location intended to optimize detection of potential viable environmental contaminants during aseptic operations.
- Observation 4
Incomplete process validation parameters
Process validation does not always include inclusion and establishment of all process parameters that should be controlled for reproducible operations. For example: a) Validation of (b)(4) and (b)(4) bag sealing processes (used in package sealing of non-sterile bulk drugs) and validation of (b) sealing of packaged and sterilized gowning (used in aseptic operations) and sterilized stoppers (used in package sealing of sterile bulk drugs) are not complete in establishing optimum ranges for sealing parameters such as the temperature, pressure and time required to achieve consistent reproducible sealing results. Also, temperature, pressure and time used for sealing during packaging processes are not recorded/documented, nor are the sealing machines used calibrated for temperature, pressure and time. b) Concerning (b)(4) manufacturing (used in API manufacturing and the source; (b)<> for (b)(1) production, (b)(1) and used in cleaning), operating ranges for process parameters are not fully established, such as determining and monitoring acceptable levels/ranges of pressures and flow for routine production, in order to sufficiently validate and control this manufacturing process. For example, appropriate ranges (upper and lower limits) for the monitoring of [illegible] for retention time and proper filter in [illegible] and manufacturing have not been fully established for processing (b)<> through (b)<> and
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Apr 1, 2026. Each one asked for a Form 483.
Inspection ending Dec 12, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jan 8, 2026. FDAgent holds no copy that FDA posted.
- Apr 1, 2026FDA-FOIA-2026-3260Form 483· 1 of 21 sitesClosed over fees
- Dec 15, 2025FDA-FOIA-2025-13973Form 483Records released
Inspection ending Dec 17, 2024VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 18, 2025. FDAgent holds no copy that FDA posted.
- Jun 16, 2025FDA-FOIA-2025-7671Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Apitoria Pharma Private LimitedD-U-N-S 861179030
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Apitoria Pharma Private Limited (D-U-N-S 861179030) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Apitoria Pharma Private LimitedSrikakulam, India · FEI 30046111827 inspections7latestSep 11, 2026NAI1 warning letter, Jun 20, 2019
- Apitoria Pharma Private LimitedSangareddy, India · FEI 30040212537 inspections7latestAug 29, 2025VAI1 warning letter, Jan 13, 2022
- Apitoria Pharma Private LimitedSangareddy District, India · FEI 30040868847 inspections7latestSep 15, 2026VAINone on file
- Apitoria Research Centre (A Division of Apitoria Pharma Private Limited)Sangareddy, India · FEI 30087652473 inspections3latestMay 24, 2024VAINone on file
- Apitoria Pharma Private LimitedAnakapalli District, India · FEI 30144770311 inspection1latestMay 19, 2023VAINone on file
- Apitoria Pharma Private LimitedSangareddy, India · FEI 30063704895 inspections5latestNov 18, 2022VAINone on file
Other FEIs recorded as Apitoria Pharma Private Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Apitoria Pharma Private LimitedFEI 3007698192Anakapalli, India
Last inspected 2024-05-10VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3004051616 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3004051616. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.