Aurobindo Pharma Ltd. Unit 5 Form 483, October 2019
FDA issued this Form 483 to Aurobindo Pharma Ltd. Unit 5 in Sangareddy, India (FEI 3004051616) at the end of a drug inspection that ended October 28, 2019. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 20, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Oct 28, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 20, 2019
- 23 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate laboratory OOS procedures
Laboratory controls do not always include the establishment of scientifically sound and appropriate procedures designed to assure that drug substances conform to appropriate standards of identity, strength, quality and purity. Specifically, when there is no scientific basis found for invalidating initial out-of-specification (OOS) API test results and no assignable cause for the OOS is determined, procedures (pZQA005) allow re-testing (following Phase I and II investigations), which permits reporting the average of [illegible] additional analyses performed by (b)<> separate analysts that meet specifications as the final data, overcoming original OOS data (No retests to overcome original OOS data have been reported).
- 2
Inadequate microbial control equipment
Equipment for adequate control over micro-organisms is not always provided when appropriate for the manufacture, processing, and packing of drug substances. a) Filling equipment (b) Block Module (b)(1) (grade A) is located in a position where aseptic procedures for operators during filling include bending down and squatting, which may result in bellowing of viable and non-viable particulate from personnel gowning during these activities having a potential affect on the sterile drug substance (e.g., (b)(1) injection-bulk). b) Goggles used by operators to protect against exposed skin in the Grade A/B areas during aseptic operations have built-in unprotected openings (holes) in the top, creating a lack of protection against a source of particles generated by, and microorganisms shed from, the body, having a potential affect on the sterile drug substance.
- 3
Insufficient environmental monitoring
The aseptic processing area is deficient regarding the system for monitoring environmental conditions. During aseptic operations in Block Module (b)(1) in grade A where sterilized stoppers are unsealed and transferred to the filling area (along with depyrogenated (b)(4) canisters), there is an absence of continuous monitoring of viables in the immediate proximity of exposed stopper packaging materials within the airflow of intervention activities and in a quantity and location intended to optimize detection of potential viable environmental contaminants during aseptic operations.
- 4
Incomplete process validation parameters
Process validation does not always include inclusion and establishment of all process parameters that should be controlled for reproducible operations. For example: a) Validation of (b)(4) and (b)(4) bag sealing processes (used in package sealing of non-sterile bulk drugs) and validation of (b) sealing of packaged and sterilized gowning (used in aseptic operations) and sterilized stoppers (used in package sealing of sterile bulk drugs) are not complete in establishing optimum ranges for sealing parameters such as the temperature, pressure and time required to achieve consistent reproducible sealing results. Also, temperature, pressure and time used for sealing during packaging processes are not recorded/documented, nor are the sealing machines used calibrated for temperature, pressure and time. b) Concerning (b)(4) manufacturing (used in API manufacturing and the source; (b)<> for (b)(1) production, (b)(1) and used in cleaning), operating ranges for process parameters are not fully established, such as determining and monitoring acceptable levels/ranges of pressures and flow for routine production, in order to sufficiently validate and control this manufacturing process. For example, appropriate ranges (upper and lower limits) for the monitoring of [illegible] for retention time and proper filter in [illegible] and manufacturing have not been fully established for processing (b)<> through (b)<> and
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.