Southern California Compounding Pharmacy, LLC Form 483, August 2019
FDA issued this Form 483 to Southern California Compounding Pharmacy, LLC in San Diego, California (FEI 3010006900) at the end of a drug inspection that ended August 1, 2019. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 21, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 1, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 21, 2019
- 81 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Environmental monitoring deficiencies
Personnel and environmental monitoring conducted within the ISO 5 Environments on a[(o)14) l frequency are deficient. Specifically, your firm does not perform growth promotion for each batch of media purchased or use a positive control when conducting'.(15) (4) gloved finger assessment and surface sampling. Your firm conducts gloved fingertip test and surface sampling as part of the compounding personnel qualification.
- 2
Gowning and aseptic practice breaches
Gowning and aseptic practices are deficient. Specifically, during the aseptic operation for Rx# [illegible] on 7/10/19, we observed operator's head enter the ISO 5 Laminar Airflow Workstation (LAFW) during aseptic operations with exposed skin on forehead and cheeks. In addition, operator's skin was exposed at the ankle during aseptic operations and lower back skin was exposed during [(o) (4)] cleaning of the ISO 7 Buffer room.
- 3
Cleaning/disinfection procedures deficient
The firm's cleaning and disinfecting procedure in the aseptic processing area are deficient. Add Continuation Page Specifically, Your firm uses non-sterile wipes sprayed with (5) (4) to wipe components prior to introduction into the ISO 5 Laminar Airflow Workstation (LAFW) and to clean ISO 5 LAFW counter top where the sterile drug products are prepared. On 7/10/19, during sterile compounding of Rx# [illegible], operator was observed moving items staged on the ISO 7 buffer room storage table to the ISO 5 LAFW without first sanitizing the items with (5) (4). In addition, your firm utilizes the following non-sterile products to clean the ISO 5 LAFW: (b) (4)
- 4
Inadequate smoke study for airflow
Smoke study conducted on 6/21/2019 to determine unidirectional airflows in ISO 5 LAFW was inadequate. Specifically, the smoke study failed to adequately simulate dynamic conditions and did not provide adequate coverage to demonstrate unidirectional airflow during routine operations. ISO 5 LAFW is where the firm produces all its sterile drug products.
- 5
Laboratory controls lack microbial testing
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans, and test procedures designed to assure drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, finished non-sterile drug products are not tested for the presence of microorganisms, for example: Ketoprofen 20%/Lidocaine 10%, lot no. 07419K20L10A, submitted for [illegible] process validation sample did not include a test for the presence of microorganisms. Add. Continuation Page
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.